| Literature DB >> 31185928 |
Kan Zhang1,2, Siyuan Wang3, Lei Wu1,2, Yun'an Song1, Meihua Cai1,2, Mazhong Zhang1,2, Jijian Zheng4,5.
Abstract
BACKGROUND: It is still unknown whether newborn infant parasympathetic evaluation (NIPE), based on heart rate variability (HRV) as a reflection of parasympathetic nerve tone, can predict the hemodynamic response to a nociception stimulus in children less than 2 years old.Entities:
Keywords: Analgesia; Newborn infant parasympathetic evaluation; Nociception; Pediatrics; Respiratory sinus arrythmia
Mesh:
Year: 2019 PMID: 31185928 PMCID: PMC6560820 DOI: 10.1186/s12871-019-0774-y
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.217
Detailed characteristics of pediatric patients
| Patients ( | |
|---|---|
| Gender (M/F) | 47/8 |
| Age (years) | 1.3 (1.1–1.5) |
| Weight (kg) | 10.6 (10.0–11.1) |
| Height (cm) | 76.1 (72.7–79.5) |
| ASA (I/II) | 50/5 |
| Surgery (n) | |
| General surgery | 20/55 |
| Urinary surgery | 20/55 |
| Orthopedic surgery | 15/55 |
| Propofol dose (mg/kg) | 3.1 (2.8–3.5) |
| Fentanyl dose (μg/kg) | 2.3 (2.1–2.6) |
ASA American Society of Anesthesiologists physical status. Data are mean (95% CI) or absolute numbers
Fig. 1Flow digram of patient/data inclusion in this observational study
Change trends for mean blood pressure (MBP), heart rate (HR), and newborn infant parasympathetic evaluation (NIPE) at five time points
| T1 | T2# | T3* | T4 | T5** | |
|---|---|---|---|---|---|
| MBP (mmHg) | 73 ± 9 | 64 ± 11 | 75 ± 17 | 56 ± 9 | 62 ± 11 |
| HR (bpm) | 129 ± 23 | 111 ± 17 | 134 ± 17 | 111 ± 14 | 115 ± 15 |
| NIPE | 40 ± 12 | 45 ± 8 | 39 ± 7 | 60 ± 14 | 56 ± 13 |
#P < 0.01 T2 vs. T1; *P < 0.01 T3 vs. T2; **P < 0.01 T5 vs. T4. T1, before anesthesia induction; T2, immediately before intubation; T3, 1st min after intubation; T4, immediately before skin incision; T5, 1st min after skin incision
Data are shown as mean ± standard deviation
Fig. 2Predictive ability of NIPE for a traditional hemodynamic change at tracheal intubation and skin incision. The area under receiver operating characteristic curve (AUC) values for this predictive ability of NIPE were 0.65 (95%CI 0.50–0.78) at endotracheal intubation and 0.58 (0.44–0.71) at skin incision