Literature DB >> 31181556

Investigation of the quinine sulfate dihydrate spectral properties and its effects on Cherenkov dosimetry.

Emilie Jean1, Marie-Ève Delage, Luc Beaulieu.   

Abstract

Recent studies have proposed that adding quinine to water while performing Cherenkov volumetric dosimetry improves the skewed percent depth dose measurement. The aim of this study was to quantify the ability of quinine to convert directional Cherenkov emission to isotropic fluorescence and evaluate its contribution to the total emitted light. Aqueous solutions of quinine were prepared with distilled water at various concentrations (0.01-1.2 g l-1). The solutions were irradiated with photon beams at 6 and 23 MV. The dependence of the light produced as a function of sample concentration was studied using a spectrometer with a fixed integration time. Spectral measurements of the luminescent solution and the blank solution (distilled water only) were taken to deconvolve the Cherenkov and quinine contribution to the overall emission spectrum. Using a CCD camera, intensity profiles were obtained for the blank and the 1.00 g l-1 solutions to compare them with the dose predicted by a treatment planning system. The luminescent intensity of the samples was found to follow a logarithmic trend as a function of the quinine concentration. Based on the spectral deconvolution of the 1.00 g l-1 solution, 52.4%  ±  0.7% and 52.7%  ±  0.7% of the signal in the visible range results from the quinine emission at 6 and 23 MV, respectively. The remaining fraction of the spectrum is due to the Cherenkov light that has not been converted. The fraction of the Cherenkov emission produced between 250 nm and 380 nm in the water and that was absorbed by the fluorophore reached 24.8% and 9.4% respectively at 6 and 23 MV. X-ray stimulated fluorescence of the quinine was then proven to be the principal cause to the increased total light output compared to the water-only signal. This new information reinforces the direct correlation of the solution intensity to the dose deposition.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31181556     DOI: 10.1088/1361-6560/ab2827

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application.

Authors:  Émily Cloutier; Luc Beaulieu; Louis Archambault
Journal:  Sci Rep       Date:  2022-06-10       Impact factor: 4.996

2.  Imaging Cherenkov emission for quality assurance of high-dose-rate brachytherapy.

Authors:  Katsunori Yogo; Akihiro Matsushita; Yuya Tatsuno; Takahiro Shimo; Seiko Hirota; Marika Nozawa; Shuichi Ozawa; Hiromichi Ishiyama; Hiroshi Yasuda; Yasushi Nagata; Kazushige Hayakawa
Journal:  Sci Rep       Date:  2020-02-27       Impact factor: 4.379

  2 in total