Maximization of the sealing effect of fibrin glue in aortic surgery.

Masaaki Naganuma1, Masatoshi Akiyama1, Hiroki Takaya1, Kei Sakuma1, Kiichiro Kumagai1, Shunsuke Kawamoto1, Osamu Adachi1, Yoshikatsu Saiki2.   

Abstract

OBJECTIVES: Fibrin glue is used to reinforce anastomosis in aortic surgery. There has not yet been a consensus on how it should be applied optimally. This study aimed to define the optimal condition of applying fibrin glue.
METHODS: In experiment 1, we determined the optimal condition for spraying fibrin glue using an expanded polytetrafluoroethylene graft within a needle hole. The length and area of the fibrin cap within the hole were measured. In experiment 2, methods for applying fibrinogen were assessed by comparing brushing and spraying. In experiment 3, swine aorta segments sutured with a Dacron graft were divided into the following three groups: nothing was applied; fibrinogen was sprayed and rubbed using brush. The aorta was clamped and blood was infused from an occlusion catheter inserted into the graft. The pressure at the first appearance of blood leak was recorded.
RESULTS: In experiment 1, among the four groups divided by the pressure and distance of spraying, the fibrin cap area in the group with 0.075 MPa and 2-cm spray distance was significantly larger than that in the group with 0.15 MPa and 2 cm (P < 0.01). In experiment 2, the fibrin cap area in the brushing group was significantly larger than that in the spraying group (P < 0.05). In experiment 3, the capacity to resist endoluminal pressure was higher in the brushing and combined spraying group compared with that in the sequential combined spraying group (P < 0.01).
CONCLUSIONS: The brush and spray methods showed excellent hemostatic outcomes.

Entities:  

Keywords:  Aortic surgery; Fibrin glue; Sealant

Mesh:

Substances:

Year:  2019        PMID: 31177484     DOI: 10.1007/s11748-019-01155-x

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  10 in total

1.  New technique for application of fibrin sealant: rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membranes.

Authors:  S Nakajima; T Fukuda; M Hasue; Y Sengoku; J Haraoka; T Uchida
Journal:  Neurosurgery       Date:  2001-07       Impact factor: 4.654

2.  Hemostatic effectiveness of a new application method for fibrin glue, the "rub-and-spray method", in emergency aortic surgery for acute aortic dissection.

Authors:  Naoki Minato; Yuji Katayama; Junji Yunoki; Hiromitsu Kawasaki; Hisashi Satou
Journal:  Ann Thorac Cardiovasc Surg       Date:  2009-08       Impact factor: 1.520

3.  [The local application of fibrinogen and collagen for hemostasis in heart surgery].

Authors:  H P Spängler; F Braun; J Holle; E Moritz; E Wolner
Journal:  Wien Med Wochenschr       Date:  1976-02-13

4.  Fibrin glue sealing of polytetrafluoroethylene vascular graft anastomoses: comparison with oxidized cellulose.

Authors:  H B Kram; P Nugent; B I Reuben; W C Shoemaker
Journal:  J Vasc Surg       Date:  1988-11       Impact factor: 4.268

5.  [Suture-free interfascicular nerve transplantation in animal experiments].

Authors:  H Matras; H P Dinges; H Lassmann; B Mamoli
Journal:  Wien Med Wochenschr       Date:  1972-09-09

6.  Development of an animal model for assessment of the hemostatic efficacy of fibrin sealant in vascular surgery.

Authors:  B S Kheirabadi; R Pearson; K Rudnicka; L Somwaru; M MacPhee; W Drohan; D Tuthill
Journal:  J Surg Res       Date:  2001-09       Impact factor: 2.192

7.  New application method of fibrin glue for more effective hemostasis in cardiovascular surgery: rub-and-spray method.

Authors:  Naoki Minato; Tomoki Shimokawa; Yuji Katayama; Noriko Yamada; Masayuki Sakaguchi; Manabu Itoh
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2004-08

8.  Midterm results of aortic repair using a fabric neomedia and fibrin glue for type A acute aortic dissection.

Authors:  Takayuki Nakajima; Kohei Kawazoe; Tsuyoshi Kataoka; Hajime Kin; Toshinobu Kazui; Hitoshi Okabayashi; Hiroyuki Niinuma
Journal:  Ann Thorac Surg       Date:  2007-05       Impact factor: 4.330

9.  Fibrin sealant improves surgical results of type A acute aortic dissections.

Authors:  J R Séguin; J M Frapier; P Colson; P A Chaptal
Journal:  Ann Thorac Surg       Date:  1991-10       Impact factor: 4.330

Review 10.  Use of fibrin sealants in cardiovascular surgery: a systematic review.

Authors:  John A Rousou
Journal:  J Card Surg       Date:  2013-04-11       Impact factor: 1.620

  10 in total
  1 in total

1.  In vitro analysis of mechanism of pulsed-laser thrombolysis.

Authors:  Daisuke Yamashita; Yuji Matsumoto; Yoshinori Tamaoki; Yukio Ueda; Hiroyuki Okada; Toshiyuki Kawashima; Yutaka Yamashita; Teiji Nakayama; Kazuo Umemura
Journal:  PLoS One       Date:  2022-01-27       Impact factor: 3.240

  1 in total