Literature DB >> 31162174

XEN Gel Stent in Pseudoexfoliative Glaucoma: 2-Year Results of a Prospective Evaluation.

Kevin Gillmann1, Giorgio E Bravetti1, André Mermoud1, Harsha L Rao2, Kaweh Mansouri1,3.   

Abstract

PRéCIS:: This study confirms the safety and efficacy of XEN gel stents in the management of pseudoexfoliative glaucoma 2 years after implantation, with success rates similar to primary open-angle glaucoma regardless of the definition of success.
PURPOSE: To compare the long-term safety and efficacy of XEN gel implant surgery (Allergan Inc., Irvine, CA) in patients with pseudoexfoliative glaucoma (PEXG) and primary open-angle glaucoma (POAG).
SETTING: Prospective, interventional study in a tertiary glaucoma center.
METHODS: A total of 110 eyes of 85 patients with POAG (57 eyes) or PEXG (53 eyes) and uncontrolled intraocular pressure (IOP) despite medical treatment underwent combined XEN+cataract surgery or standalone XEN surgery. Mean IOP, mean number of medications, needling rates, and incidence of adverse effects were compared between the 2 groups. Complete surgical success was defined as an unmedicated IOP≤12, 15, 16, or 18 mm Hg at 2 years, both with and without a 20% reduction from baseline.
RESULTS: Combined XEN+cataract surgery was performed in 72% of POAG and 76% of PEXG eyes (P=0.67), the remainder underwent standalone XEN surgery. Patient characteristics were similar between the 2 groups except for older age for the patients with PEXG (78.5±8.5 vs. 71.3±8.7 y; P<0.005). Mean medicated IOP were 19.8±5.8 mm Hg (POAG) versus 19.8±8.2 mm Hg (PEXG) at baseline (P=0.98), and 14.5±3.6 mm Hg (-26.8%) versus 14.2±3.8 mm Hg (-28.3%), respectively, at 2 years (P=0.75). Mean medications concomitantly dropped from 1.9±1.6 (POAG) versus 2.0±1.3 (PEXG) to 0.6±0.9 versus 0.4±0.7, respectively (P=0.29). Using the 16 mm Hg threshold, 51.4% (POAG) versus 57.1% (PEXG) eyes achieved complete success (P=0.70) at 2 years. The difference in success rates between the 2 groups was not statistically significant under any of the definitions of success. By 24 months, needling was performed in 42.8% (POAG) and 43.2% (PEXG) (P=0.64), with an average time to needling of 162.8 and 134.9 days, respectively (P=0.46). The rates of adverse effects were 30.6% (POAG) and 36.4% (PEXG) (P=0.66), and additional glaucoma surgeries were carried out in 14.3% (POAG) versus 15.9% (PEXG) (P=0.89).
CONCLUSIONS: The XEN gel implant as a standalone or combined procedure demonstrated similar efficacy and safety results in PEXG and POAG eyes.

Entities:  

Year:  2019        PMID: 31162174     DOI: 10.1097/IJG.0000000000001295

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  22 in total

1.  Multicenter case series of standalone XEN implant vs. combination with phacoemulsification in Turkish patients.

Authors:  Muhsin Eraslan; Altan Atakan Özcan; Volkan Dericioğlu; Emine Çiloğlu
Journal:  Int Ophthalmol       Date:  2021-05-28       Impact factor: 2.031

2.  Complications and post-operative interventions in XEN45 gel stent implantation in the treatment of open angle glaucoma-a systematic review and meta-analysis.

Authors:  Bjorn Kaijun Betzler; Sheng Yang Lim; Boon Ang Lim; Vivien Cherng Hui Yip; Bryan Chin Hou Ang
Journal:  Eye (Lond)       Date:  2022-03-28       Impact factor: 3.775

3.  One-year outcomes of microshunt implantation in pseudoexfoliation glaucoma.

Authors:  Matthias Nobl; Sigrid Freissinger; Stefan Kassumeh; Siegfried Priglinger; Marc J Mackert
Journal:  PLoS One       Date:  2021-08-27       Impact factor: 3.240

4.  Glaucoma Medication and Quality of Life after Phacoemulsification Combined with a Xen Gel Stent.

Authors:  Christian Pahljina; Stephanie Sarny; Lukas Hoeflechner; Thomas Falb; Gernot Schliessleder; Marlene Lindner; Domagoj Ivastinovic; Kaweh Mansouri; Ewald Lindner
Journal:  J Clin Med       Date:  2022-06-15       Impact factor: 4.964

5.  Comparison of Clinical Outcomes Following Gel Stent Implantation via Ab-Externo and Ab-Interno Approaches in Patients with Refractory Glaucoma.

Authors:  Mark J Gallardo; Logan R Vincent; Matthew Porter
Journal:  Clin Ophthalmol       Date:  2022-07-06

6.  Comparison of Clinical Outcomes with Open Versus Closed Conjunctiva Implantation of the XEN45 Gel Stent.

Authors:  Anna Do; Elyse McGlumphy; Aakriti Shukla; Sonal Dangda; Joel S Schuman; Michael V Boland; Jithin Yohannan; Joseph F Panarelli; E Randy Craven
Journal:  Ophthalmol Glaucoma       Date:  2020-12-13

Review 7.  Standalone XEN45 Gel Stent implantation versus combined XEN45-phacoemulsification in the treatment of open angle glaucoma-a systematic review and meta-analysis.

Authors:  Sheng Yang Lim; Bjorn Kaijun Betzler; Leonard Wei Leon Yip; Syril Dorairaj; Bryan Chin Hou Ang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-04-29       Impact factor: 3.535

8.  Three-year effectiveness and safety of the XEN gel stent as a solo procedure or in combination with phacoemulsification in open-angle glaucoma: a multicentre study.

Authors:  Herbert Reitsamer; Vanessa Vera; Simon Ruben; Leon Au; Jorge Vila-Arteaga; Miguel Teus; Markus Lenzhofer; Andrew Shirlaw; Zhanying Bai; Mini Balaram; Ingeborg Stalmans
Journal:  Acta Ophthalmol       Date:  2021-05-10       Impact factor: 3.988

9.  A Retrospective Analysis of Safety and Efficacy of XEN 45 Microstent Combined Cataract Surgery in Open-Angle Glaucoma over 24 Months

Authors:  Sevgi Subaşı; Nurşen Yüksel; Fevzi Özer; Büşra Yılmaz Tugan; Dilara Pirhan
Journal:  Turk J Ophthalmol       Date:  2021-06-29

10.  XEN Glaucoma Implant for the Management of Operated Uncontrolled Glaucoma: Results and Complications during a Long-Term Follow-Up.

Authors:  Katarzyna Lewczuk; Joanna Konopińska; Joanna Jabłońska; Jacek Rudowicz; Patrycja Laszewicz; Zofia Mariak; Marek Rękas
Journal:  J Ophthalmol       Date:  2021-07-09       Impact factor: 1.909

View more