Simultaneous and direct determination of urea and creatinine in human urine using a cost-effective flow injection system equipped with in-house contactless conductivity detector and LED colorimeter.

Sumonmarn Chaneam1, Kamparnart Kaewyai2, Thitirat Mantim3, Rasamee Chaisuksant4, Prapin Wilairat5, Duangjai Nacapricha2.   

Abstract

This work presents a cost-effective and simple flow injection analysis (FIA) system for simultaneous and direct determination of urea and creatinine in human urine. The FIA system comprises two in-house detectors, a contactless conductivity detector and a light emitting diode (LED) detector. The contactless detector was built as a flow-through detection cell with axial electrodes, commonly known as capacitively coupled contactless conductivity detector (C4D) and the diode detector was fabricated based on the concept of paired emitter detector diodes (PEDD). With appropriate dilution of urine, the sample is directly injected into a stream of glycine-NaOH buffer pH 8.8 (the gas donor stream) and is carried by the carrier through a urease minicolumn for on-line enzymatic hydrolysis. The generated NH3 diffuses from the carrier stream through a porous polytetrafluoroethylene (PTFE) membrane into a stream of deionized water (the acceptor stream) leading to an increase in the signal at the C4D due to the NH3 dissolution in the water. In this system, creatinine is determined based on the Jaffé reaction by merging a stream of alkaline picrate with the gas donor stream. The change in color is detected using the PEDD equipped with two green LEDs. Under the optimum condition, the linear range of urea and creatinine were 30-240 mg L-1 and 10-500 mg L-1, with limits of detection of 9.0 mg L-1 and 0.9 mg L-1, respectively. The proposed system provides satisfactorily good precision (RSD < 3%), with sample throughput of 31 sample h-1 for the two analytes. The FIA system tolerates potential interference commonly found in human urine. The system was successfully applied and validated with selected reference methods.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Capacitively coupled contactless conductivity detector (C4D); Creatinine; Flow injection analysis (FIA); Paired emitter detector diodes (PEDD); Urea; Urine

Mesh:

Substances:

Year:  2019        PMID: 31146836     DOI: 10.1016/j.aca.2019.05.003

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  A Study on Double Inputs Direct Contact and Single Output Capacitively Coupled Conductivity Detector.

Authors:  Shuangfei Zhang; Hongyan Yuan; Dan Xiao
Journal:  Sensors (Basel)       Date:  2022-04-02       Impact factor: 3.576

2.  Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis.

Authors:  Thitirat Mantim; Korbua Chaisiwamongkhol; Kanchana Uraisin; Peter C Hauser; Prapin Wilairat; Duangjai Nacapricha
Journal:  Molecules       Date:  2020-05-13       Impact factor: 4.411

Review 3.  Recent advancements in urea biosensors for biomedical applications.

Authors:  Saravjeet Singh; Minakshi Sharma; Geeta Singh
Journal:  IET Nanobiotechnol       Date:  2021-05-19       Impact factor: 2.050

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.