| Literature DB >> 31142607 |
B A Pinsky1,2, R T Hayden3.
Abstract
The timely and accurate diagnosis of respiratory virus infections has the potential to optimize downstream (posttesting) use of limited health care resources, including antibiotics, antivirals, ancillary testing, and inpatient and emergency department beds. Cost-effective algorithms for respiratory virus testing must take into consideration numerous factors, including which patients should be tested, what testing should be performed (for example, antigen testing versus reverse transcription-PCR testing or influenza A/B testing versus testing with a comprehensive respiratory virus panel), and the turnaround time necessary to achieve the desired posttesting outcomes. Despite the clinical impact of respiratory virus infections, the cost-effectiveness of respiratory virus testing is incompletely understood. In this article, we review the literature pertaining to the cost-effectiveness of respiratory virus testing in pediatric and adult patient populations, in emergency department, outpatient, and inpatient clinical settings. Furthermore, we consider the cost-effectiveness of a variety of testing methods, including rapid antigen tests, direct fluorescent antibody assays, and nucleic acid amplification tests.Entities:
Keywords: respiratory viruses
Mesh:
Year: 2019 PMID: 31142607 PMCID: PMC6711893 DOI: 10.1128/JCM.00373-19
Source DB: PubMed Journal: J Clin Microbiol ISSN: 0095-1137 Impact factor: 5.948
FDA-cleared influenza A/B rapid antigen tests
| Manufacturer | Product | Platform/instrument | Approved specimen type(s) |
|---|---|---|---|
| Abbott | Binax Now Influenza A & B Card 2 | Alere reader | |
| Becton Dickinson & Co. | BD Veritor Flu A + B | BD Veritor reader, BD Veritor Plus analyzer | |
| Quidel Corp. | Sofia Influenza A + B FIA | Sofia FIA analyzer, Sofia 2 FIA analyzer | |
| Quidel Corp. | QuickVue Influenza A + B | NA | |
| Princeton BioMeditech Corp. | BioSign Flu A & B, Labsco Advantage Flu A & B, LifeSign Status Flu A & B, OraSure QuickFlu Rapid A + B, Polymedco Poly stat Flu A&B, Sekisui Diagnostics OSOM Ultra Flu A & B, Meridian BioScience ImmunoCard Stat! Flu A&B, McKesson Consult Diagnostics Influenza A&B | NA | |
| Remel/Thermo Fisher | Xpect Flu A & B | NA | Nasal wash |
NPS, nasopharyngeal swab; NS, nasal swab; NA, nasal aspirate; NPA, nasopharyngeal aspirate; NPW, nasopharyngeal wash; VTM, viral transport medium; NA, not applicable. Specimen types listed in bold are CLIA waived.
FDA-cleared and CLIA-waived respiratory virus NAATs
| Manufacturer | Product | Platform/instrument | Approved specimen type(s) |
|---|---|---|---|
| Abbott | Alere i Influenza A&B 2 | Alere i (ID NOW) | NS direct, NPS direct, NS, NPS |
| Abbott | Alere i Influenza RSV | Alere i (ID NOW) | NPS direct, NPS |
| BioFire Diagnostics | BioFire FilmArray respiratory panel EZ | BioFire FilmArray | NPS |
| Cepheid | Xpert Xpress Flu | GeneXpert Xpress | NS, NPS |
| Cepheid | Xpert Xpress Flu/RSV | GeneXpert Xpress | NS, NPS |
| Mesa Biotech, Inc. | Accula Flu A/Flu B | Accula Dock | NS |
| Mesa Biotech, Inc. | Accula RSV | Accula Dock | NS |
| Roche | cobas Liat Influenza A/B assay | cobas Liat | NPS |
| Roche | cobas Liat Influenza A/B & RSV assay | cobas Liat | NPS |
| Sekisui Diagnostics | Silaris Influenza A&B test | Silaris Dock | NS direct |
NPS, nasopharyngeal swab; NS, nasal swab.
Selected FDA-cleared but nonwaived respiratory virus NAATs
| Manufacturer | Product | Platform/instrument | Approved specimen type(s) |
|---|---|---|---|
| BioFire Diagnostics | BioFire FilmArray respiratory panel 2 | BioFire FilmArray | NPS |
| BioFire Diagnostics | BioFire FilmArray respiratory panel | BioFire FilmArray | NPS |
| BioFire Diagnostics | BioFire FilmArray pneumonia panel | BioFire FilmArray | IS, TRA, BAL fluid |
| Cepheid | Xpert Flu/RSV XC | GeneXpert | NPS, NPA, NPW |
| Cepheid | Xpert Xpress Flu | GeneXpert | NS, NPS |
| Cepheid | Xpert Xpress Flu/RSV | GeneXpert | NS, NPS |
| Diasorin | Simplexa Flu A/B & RSV Direct | Liason MDX | NPS |
| GenMark Diagnostics | ePlex respiratory pathogen panel | ePlex | NPS |
| Hologic, Inc. | Panther Fusion Flu A/B/RSV assay | Panther Fusion | NPS |
| Hologic, Inc. | Panther Fusion AdV/HMPV/RV assay | Panther Fusion | NPS |
| Hologic, Inc. | Panther Fusion Paraflu assay | Panther Fusion | NPS |
| Luminex | Aries Flu A/B & RSV assay | Aries | NPS |
| Luminex | Verigene Respiratory Pathogens Flex | Verigene reader and processor SP | NPS |
| Qiagen | QIAstat-Dx respiratory panel | QIAstat-Dx | NPS |
| Quidel | Solana Influenza A + B assay | Solana | NS, NPS |
| Quidel | Solana Influenza RSV+hMPV assay | Solana | NS, NPS |
NPS, nasopharyngeal swab; NS, nasal swab; NPA, nasopharyngeal aspirate; NPW, nasopharyngeal wash; IS, induced/expectorated sputum; TRA, tracheal aspirate; BAL, bronchoalveolar lavage.
FIG 1Respiratory virus testing algorithms. (A) All patients with ILI are tested using an influenza A/B test. (B) All patients with ILI are tested with a respiratory pathogen panel. (C) Patients with ILI are tested with an influenza A/B test and, if the results are negative, then reflex testing with a respiratory pathogen panel is performed. (D) Patients with ILI are tested with an influenza A/B test or a respiratory pathogen panel depending on underlying diseases and the severity of the presentation.