Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia.

Ya-Li Du1, Geng Wang1, Hui-Chun Huang1, Li-Yu Lin1, Chuang Jin1, Li-Fang Liu1, Xiu-Ru Liu1, Ming-Zhi Zhang1.   

Abstract

This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length (AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements were performed using both biometers before surgery. Uneventful cataract surgery was performed in all patients. Postoperative manifest refraction was obtained 3wk after surgery or later. A total of 67 eyes were examined. The AL, keratometry (K), and anterior chamber depth (ACD) of the two biometers showed excellent agreement. Predicted errors were similar and a strong positive correlation was observed (r=0.909). Out of 21 eyes (31.34%) with unsuccessful AL readings using the IOL Master 500, 20 eyes of them could be measured using OA-2000. Therefore, the biometric parameters measured by the two biometers showed good agreement. However, OA-2000 had a lower AL measurement failure rate.

Entities:  

Keywords:  IOL Master 500; IOL power calculation; OA-2000; biometry measurement; cataract; high myopia

Year:  2019        PMID: 31131247      PMCID: PMC6520281          DOI: 10.18240/ijo.2019.05.23

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  4 in total

1.  Comparison of acquisition rate and agreement of axial length with two swept-source optical coherence tomographers and a partial coherence interferometer.

Authors:  Shi-Ming Cheng; Wen-Tao Yan; Jia-Sheng Zhang; Tian-Tian Li; Xi Li; A-Yong Yu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-04-30       Impact factor: 3.535

2.  Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.

Authors:  Mi Yeon Song; Sung Rae Noh; Kook Young Kim
Journal:  PLoS One       Date:  2021-05-04       Impact factor: 3.240

3.  Comparative analysis of two optical biometry devices: high wavelength swept source OCT versus partial coherence interferometry.

Authors:  Eszter Szalai; Adrienne Csutak
Journal:  Int Ophthalmol       Date:  2021-10-11       Impact factor: 2.029

4.  A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients.

Authors:  Jianhong Jiang; Xiaojing Pan; Mingming Zhou; Xiaoyun Wang; Hai Zhu; Dongfang Li
Journal:  Sci Rep       Date:  2022-07-27       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.