An artificial cornea or keratoprosthesis requires high mechanical strength, good biocompatibility, and sufficient wear and corrosion resistance to withstand the hostile environment. We report a reduced graphene oxide-reinforced titania-based composite for this application. Graphene oxide nanoparticles (GO) and liquid crystalline graphene oxide (LCGO) were the graphene precursors and mixed with titanium dioxide (TiO2) powder. The composites reinforced with reduced GO or LCGO were produced through spark plasma sintering (SPS). The mechanical properties (Young's modulus and hardness), wear behaviour and corrosion resistance were studied using nanoindentation, anoidic polarization, long-term corrosion assay in artificial tear fluid and tribology assay in corroboration with atomic force microscopy and scanning electron microscopy. Biocompatibility was assessed by human corneal stromal cell attachment, survival and proliferation, and DNA damages. Sintered composites were implanted into rabbit corneas to assess for in vivo stability and host tissue responses. We showed that reduced graphene/TiO2 hybrids were safe and biocompatible. In particular, the 1% reduced LCGO/TiO2 (1rLCGO/TiO2) composite was mechanically strong, chemically stable, and showed better wear and corrosion resistance than pure titania and other combinations of graphene-reinforced titania. Hence the 1rLCGO/ TiO2 bioceramics can be a potential skirt biomaterial for keratoprosthesis to treat end-stage corneal blindness. STATEMENT OF SIGNIFICANCE: The osteo-odonto-keratoprosthesis (OOKP) is an artificial cornea procedure used to restore vision in end-stage corneal diseases, however it is contraindicated in young subjects, patients with advanced imflammatory diseases and posterior segment complications. Hence, there is a need of an improved keratoprosthesisskirt material with high mechanical and chemical stability, wear resistance and tissue integration ability. Our study characterized a reduced graphene oxide-reinforced titania-based biomaterial, which demonstrated strong mechanical strength, wear and corrosion resistance, and was safe and biocompatible to human corneal stromal cells. In vivo implantation to rabbit corneas did not cause any immune and inflammation outcomes. In conclusion, this invention is a potential keratoprosthesis skirt biomaterial to withstand the hostile environment in treating end-stage corneal blindness.
Copyright © 2019 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biocompatibility; Corneal implantation; Reduced graphene oxide; Spark plasma sintering; Titanium dioxide; Wear and corrosion resistance

Year:  2019        PMID: 31129362     DOI: 10.1016/j.actbio.2019.05.053

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  2 in total

Review 1.  Engineered titania nanomaterials in advanced clinical applications.

Authors:  Padmavati Sahare; Paulina Govea Alvarez; Juan Manual Sanchez Yanez; Juan Gabriel Luna Bárcenas; Samik Chakraborty; Sujay Paul; Miriam Estevez
Journal:  Beilstein J Nanotechnol       Date:  2022-02-14       Impact factor: 3.649

2.  Effects of the Surface Charge of Graphene Oxide Derivatives on Ocular Compatibility.

Authors:  Liyuan Rong; Yan Fu; Qiyou Li; Xinji Yang; Yueyue Li; Liang Yan; Liqiang Wang; Wei Wu
Journal:  Nanomaterials (Basel)       Date:  2022-02-22       Impact factor: 5.076

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.