Petri Mäkinen1,2, Anne Huhtala1,2, Juhani Pietilä1,2, Janika Nättinen3, Teppo Rajala1, Kalle Salmenhaara2, Magomed Udratov1, Hannu Uusitalo3,4.
Abstract
PURPOSE: To study self-reported patient satisfaction and dry eye symptoms in hyperopic correction with femtosecond laser-assisted in situ keratomileusis (FS-LASIK). PATIENTS AND METHODS: Ninety-eight eyes (53 patients) were treated with FS-LASIK for hyperopia. Patients' self-reported dry eye symptoms and satisfaction with near and far vision were graded on the visual analog scale (VAS) preoperatively and 1 month postoperatively.Entities:
Keywords: FS-LASIK; dry eye; femtosecond laser in situ keratomileusis; hyperopia; patient satisfaction
Year: 2019 PMID: 31114152 PMCID: PMC6487895 DOI: 10.2147/OPTH.S195991
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Figure 1Flowchart of patient selection.
Preoperative and postoperative patient data
| Variable | Preoperative | 1 month | |
|---|---|---|---|
|
| |||
| Sphere (D) | +2.24±1.25 | −0.54±0.98 | <0.0001 |
| +2.08±1.10 | −1.53±0.61 | <0.0001 | |
| +2.37±1.35 | +0.17±0.37 | <0.0001 | |
|
| |||
| Cylinder (D) | −0.71±0.90 | −0.20±0.30 | <0.0001 |
| −0.55±0.60 | −0.22±0.33 | 0.0003 | |
| −0.83±1.08 | −0.18±0.28 | <0.0001 | |
|
| |||
| Spherical equivalent Refraction (D) | +1.88±1.17 | −0.70±0.96 | <0.0001 |
| +1.80±1.07 | −1.65±0.54 | <0.0001 | |
| +1.95±1.26 | +0.08±0.31 | <0.0001 | |
|
| |||
| Keratometric power K1(D) | 42.66±1.52 | 45.03±2.12 | <0.0001 |
| 42.89±1.38 | 46.07±1.90 | <0.0001 | |
| 42.47±1.62 | 44.15±1.91 | <0.0001 | |
|
| |||
| Keratometric power K2(D) | 43.69±1.50 | 46.10±2.12 | <0.0001 |
| 43.79±1.43 | 47.10±2.03 | <0.0001 | |
| 43.61±1.74 | 45.26±2.14 | <0.0001 | |
Notes: Values are presented as mean ± SD. P-values were calculated by Student’s paired t-test.
Figure 2Standard graphs for reporting refractive surgery outcomes. (A) UDVA, (B) UDVA vs CDVA, (C) change in CDVA, (D) SEQ refraction attempted vs achieved in emmetropic eyes, (E) SEQ refraction attempted vs achieved in monovision eyes, (F) SEQ refraction accuracy, (G) refractive astigmatism, (H) TIA vs SIA, (I) refractive astigmatism angle of error. In (D and G), the values within 0.5 D are shown by green line and those within 1.0 D by pink line.
Abbreviations: Arith, arithmetic; Abs, absolute; CC/wise, counter clockwise; C/wise, clock wise; CDVA, corrected distance visual acuity; preop, preoperative; postop, postoperative; SEQ, spherical equivalent refraction; SIA, surgically induced astigmatism; TIA, target-induced astigmatism; UDVA, uncorrected distance visual acuity.
Pre- and postoperative dry eye symptoms and patient satisfaction graded by visual analog scaling scores
| Variable | Preoperative | 1 month | |
|---|---|---|---|
|
| |||
| Dry eye symptoms | 2.7±2.0 | 2.8±2.0 | 0.66 |
|
| |||
| Patient satisfaction, far vision | 71.6±20.3 | 88.8±10.0 | <0.0001 |
| 71.2±19.8 | 89.2±8.7 | <0.0001 | |
| 73.7±23.7 | 86.9±15.3 | 0.22 | |
|
| |||
| Patient satisfaction, near vision | 52.9±26.6 | 88.0±14.1 | <0.0001 |
| 51.7±26.2 | 89.3±13.2 | <0.0001 | |
| 58.9±29.1 | 81.6±17.4 | 0.11 | |
Notes: Values are presented as mean ± SD. P-values were calculated by Student’s paired t-test.
Figure 3(A) In 44 monovision patients, satisfaction with far vision correlated negatively with postoperative dry eye experience (r=−0.31, P=0.04). Patient satisfaction with far vision decreased with increasing dry eye symptoms. (B) In 44 monovision patients, satisfaction with near vision correlated negatively with postoperative spherical equivalent refraction from target (r=−0.45, P=0.002). Patients were more satisfied with their near vision when postoperative spherical equivalent from target was on the myopic side. (C) In nine emmetropic patients, satisfaction with near vision correlated negatively with patient age (r=−0.69, P=0.04). Patient satisfaction with near vision decreased with patient age.
Literature review of the correction of hyperopia by FS-LASIK
| Accuracy (%) | Efficacy UDVA (%) | Safety (%) Loss of Snellen lines | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| |||||||||||||
| First author | Year | N (eyes) | Technique | Preop SE Mean ± SD (D) (range) | Age (y) (range) | Follow-up | Postop SE Mean ± SD (D) (range) | ±0.50 D | ±1.00 D | ≤20/20 | ≤20/40 | 1 line | 2 lines |
|
| |||||||||||||
| Mäkinen (current study) | 2018 | 100 | Femto LDV or Visumax and Wavelight EX500 | +1.96±1.27 (+0.13 to +6.13) | 49.6±10.4 (22 to 62) | 1 month | −0.66±0.99 (−2.75 to +1.50) | 89 | 99 | 89 (plano target) | 100 (plano target) | 3 | 0 |
| Garcia-Gonzales | 2018 | 76 with MMC 76 without MMC | 60 kHz Intralase and Esiris Swind | +2.71±1.30 (+2.00 to +6.25) | 44.6±1.1 (41 to 55) | 6 months | +0.18±0.40 (−1.00 to +1.75) | 76.3 | 90.8 | 71.1 | 100 | 6.6 | 2.6 |
| +2.90±1.10 (+2.00 to +6.25) | 43.6±1.3 (41 to 55) | +0.42±0.50 (−0.625 to +2.00) | 57.9 | 82.9 | 53.9 | 100 | 9.2 | 5.3 | |||||
| Reinstein | 2017 | 785 | Hansatome microkeratome (38% of eyes) or Visumax FS (62% of eyes) and MEL 80 excimer laser | +4.52±0.86 (+0.63 to +8.38) | 50.4±12 (18 to 70) | 2 years | +0.41 | 50 | 77 | 81 (plano target) | 95 (plano target) | 22 | 0.5 |
| El-Naggar | 2017 | 40 | Wavelight FS200 and Wavelight EX500 | +2.55±1.17 (+1.00 to +6.00) | 47.2±3.84 (42 to 56) | 1 year | +0.10 | 95 | 100 | 85 | 100 | 0 | 0 |
| Schallhorn | 2017 | 550 | iFs and VISX STAR S4 IR OZ 6–9 mm | +1.76±0.50 (+0.50 to +3.00) (sphere) −0.51±0.48 (−4.00 to 0.0) (cylinder) | 51.9±3.8 | 3 months | Near eye: −1.81±0.74 (sphere) Distance eye: −0.03±0.30 (sphere) −0.41±0.45 (−2.50 to 0.0) (cylinder) | – | – | 77.5 | 95.6 | – | 4.2 |
| Plaza-Puche | 2016 | 51 | 60 kHz Intralase and 500 Hz Amaris OZ 6.2–6.9 mm | +6.33±0.83 (+5.00 to 8.50) | 40±10 (21 to 54) | 6 months | +0.50±1.06 (−0.50 to +3.38) | – | 71 | 53 | 98 | 11 | 6.5 |
| Courtin | 2016 | 98 | Wavelight FS200 and Wavelight EX500 | Non-dominant eye: +1.91±0.94 (+0.125 to +4.50) Dominant eye: +1.87±0.86 (+0.25 to +4.25) | 56.5±5.7 (47 to 70) | 6 months | Distance eye: −1.06±0.74 Near eye: +0.32±0.56 | – | – | 91 | – | 1.0 | 0 |
| Plaza-Puche | 2015 | 86 | 60 kHz Intralase and 500 Hz Amaris OZ 6.3–7.0 mm | +2.66±1.68 (−1.38 to +5.75) | 40±10 (23 to 64) | 3 years | +0.40±0.65 (−1.63 to +2.00) | 70 | 85 | 76 | 99 | 6.2 | 1.2 |
| Antonios | 2015 | 72 | Femto LDV and Amaris | +2.24±0.95 (+0.050 to −4.75 D) | 46±10 (18 to 68) | 6 months | −0.32±0.76 (−2.13 to +1.50) | 65 | 90 | 88 | 100 | 0 | 0 |
| Alio | 2013 | 27 | 30 kHz or 60 kHz Intralase and 500 Hz Amaris OZ 6.2–6.0 mm | +6.33±0.83 (+5.00 to +8.50) | – | 6 months | +0.55±1.09 (−0.50 to +3.38) | 70 | – | 44 | 92 | 8 | 0 |
| Tanzer | 2013 | 25 | 60 kHz or 150 kHz Intralase, excimer laser N/A | +1.86 | 36 | 3 months | – | – | – | 95.7 | 100 | 4 | 0 |
| Leccisotti | 2014 | 800 | Femto LDV and Technolas 217P | +3.41±1.16 (1.00 to +6.50) | 41.13±8.75 | 9 months | −0.06±0.26 | 74.3 | 88.4 | – | 95 | 7.3 | 0.4 |
| Ivarsen | 2013 | 52 | Visumax and MEL-80 | +1.31±2.31 (SE) +3.5±2.3 (0 to +8.75) (sphere) −4.4±1.1 (−2.0 to −6.5) (cylinder) | 35.6±9.2 (21 to 53) | 3 months | +0.10±0.71 (SE) +0.8±0.8 (−0.25 to +3.0) (sphere) −1.4±0.9 (−4.5 to 0.0) (cylinder) | – | – | 71 | 90 | – | – |
| Kanellopoulos | 2012 | 202 | FS and 400 Hz eye-Q | +3.04±1.75 (+0.75 to +7.25) (sphere) | 40±12 (19 to 62) | 2 years | −0.39±0.30 (sphere) | 76 | 94 | 59 | 96 | 2.9 | 2.4 |
| Gil-Cazorla | 2011 | 72 | 60 kHz Intralase and Esiris Schwind | +2.45±1 (+0.012 to +4.25) | 37.7±8.5 (18 to 35) | 3 months | +0.24±0.4 (−0.62 to +1.75) | 73.6 | 93.0 | – | – | 0 | 0 |
| Ghanem | 2007 | 47 | Intralase FS | +2.38±1.43 | 45 | 2 months | −0.09±0.87 | 68 | 81 | 24 | 97 | 32 | 6 |
Abbreviations: D, diopters; FS-LASIK, femtosecond laser-assisted in situ keratomileusis; MMC, mitomycin; SE, spherical equivalent; UDVA, uncorrected distance visual acuity; OZ, optical zone.