Literature DB >> 31108191

Minimal invasive plating of distal radius fractures. A safe procedure?

T Neubauer1, M Plecko2, S Grechenig3, A Hartmann4, R Ortmaier4, W Hitzl5, G Feigl3.   

Abstract

BACKGROUND: Minimal invasive plate osteosynthesis (MIPO) with preservation of the pronator quadratus (PQ) muscle represents a new technique for stabilization of distal radius fractures. However, the complex anatomy of the distal radius metaphysis requires implants with features that address all morphologic specifics of this area to avoid complications, which are still reported with this technique. It was the aim of our anatomic investigation to evaluate the feasibility of plate insertion via a minimal transverse approach as well as the risk of soft- tissues compromise with the use of an implant, which is only partially adapted to the characteristics of distal radius metaphysis.
METHODS: Twenty forearm specimens, conservated with Thiels method, have been used for this study. The majority (n = 19/20) of implants (2.4 mm small fragment juxta-articular locking compression/ LCP T-plate -5-hole; Depuy - Synthes®, Solothurn, Switzerland) could be inserted easily and all were seated proximal to the so called "watershed line" (n = 20/20).
RESULTS: In a total of 8/20 specimens close contacts or potential compromise to neighboring soft- tissues was seen: perforation of the PQ muscle by the plate occurred in 2/20 specimens and was related to an extreme muscle morphology. In 7/20 specimens close contacts between the T-plate and other soft tissues were observed, which were exclusively located at the radial edge of the distal transverse bar. They affected the brachio-radialis tendon (elevation: 2/20, side-to-side contact: 3/20, overriding: 1/20) and the radial artery (elevation: 4/20, side-to-side contact: 2/20, overriding: 1/20). No significant differences of morphologic types of PQ muscle and the difficulty of plate insertion, adjustment on the bone, PQ muscle damage and contact to neighboring soft-tissues could be evaluated.
CONCLUSIONS: Insertion of volar radius plates through a MIPO approach can be easily accomplished without detachment and damage to the PQ muscle even with grossly adapted implants. However, perfectly pre-shaped plates which are adapted to all anatomic aspects of the distal radius metaphysis are required to achieve optimal contact with the metaphyseal bone and to avoid potential complications.
Copyright © 2019 Elsevier GmbH. All rights reserved.

Entities:  

Keywords:  Anatomy; Distal radius fractures; Minimal invasive plating; Pronator quadratus

Mesh:

Year:  2019        PMID: 31108191     DOI: 10.1016/j.aanat.2019.05.001

Source DB:  PubMed          Journal:  Ann Anat        ISSN: 0940-9602            Impact factor:   2.698


  1 in total

1.  [Effectiveness of pronator quadratus muscle sparing in volar plate fixation for unstable distal radius fracture in adults].

Authors:  Xiaolin Liu; Hui Ye; Jinxing Shi
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-07-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.