Literature DB >> 32666721

[Effectiveness of pronator quadratus muscle sparing in volar plate fixation for unstable distal radius fracture in adults].

Xiaolin Liu1, Hui Ye1, Jinxing Shi1.   

Abstract

OBJECTIVE: To investigate the effectiveness of pronator quadratus muscle sparing in volar plate fixation for unstable distal radius fracture in adults.
METHODS: The clinical data of 62 cases of unstable distal radius fractures between January 2017 and December 2018 were retrospectively analyzed. According to the different methods of intraoperative exposure, the patients were divided into the observe group (28 cases with the pronator quadratus muscle sparing surgery) and the control group (32 cases with cutting the pronator quadratus muscle in operation and repairing it after volar plate fixation). There was no significant difference in general data such as gender, age, handedness, cause of injury, fracture classification, time from injury to operation, visual analogue scale (VAS) score, and range of motion (ROM) of wrist (flexion, extension, pronation, and supination) before operation between the two groups ( P>0.05). The operation time, intraoperative blood loss, postoperative hospital stay, fracture healing time, and postoperative complications were recorded and compared between the two groups. VAS score and ROM of wrist of two groups before operation and at 3 days and 3 months after operation were calculated and compared. The wrist function was evaluated according to the Krimmer evaluation criteria at 6 months after operation.
RESULTS: There was no significant difference in operation time and intraoperative blood loss between the two groups ( P>0.05). The postoperative hospital stay and fracture healing time of the observe group were significantly shorter than those of the control group ( P<0.05). Patients in both groups were followed up 6-30 months, with an average of 13 months. The VAS score and ROM of wrist of the observe group at 3 days after operation were superior to the control group ( P<0.05), but there was no significant difference between the two groups at 3 months after operation ( P>0.05). At 6 months after operation, according to Krimmer evaluation criteria, the wrist function of the observe group was excellent in 21 cases and good in 7 cases, with an excellent and good rate of 100%; and the wrist function of the control group was excellent in 22 cases, good in 11 cases, and fair in 1 case, with an excellent and good rate of 97.1%. There was no significant difference in wrist function between the two groups ( χ 2=1.344, P=0.511). One case of poor incision healing occurred in the observe group, and 7 cases of poor incision healing and 5 cases of tendon pain occurred in the control group after operation. The incidence of postoperative complications was less in the observe group (3.6%) than in the control group (35.3%) ( χ 2=9.325, P=0.002).
CONCLUSION: It is feasible of the pronator quadratus muscle sparing in the volar plate fixation for unstable distal radius fracture in adults. It is beneficial to recover wrist function early after operation, reduce postoperative complications, shorten the length of hospitalization, protect the soft tissue of fracture site, and promote fracture healing.

Entities:  

Keywords:  Unstable distal radius fracture; internal fixation; pronator quadratus muscle; volar plate

Mesh:

Year:  2020        PMID: 32666721      PMCID: PMC8180435          DOI: 10.7507/1002-1892.201911089

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  17 in total

Review 1.  Enhanced recovery after surgery: A clinical review of implementation across multiple surgical subspecialties.

Authors:  Thomas W Smith; Xuanji Wang; Marc A Singer; Constantine V Godellas; Faaiza T Vaince
Journal:  Am J Surg       Date:  2019-11-16       Impact factor: 2.565

2.  Minimal invasive plating of distal radius fractures. A safe procedure?

Authors:  T Neubauer; M Plecko; S Grechenig; A Hartmann; R Ortmaier; W Hitzl; G Feigl
Journal:  Ann Anat       Date:  2019-05-17       Impact factor: 2.698

3.  "Cold air" and/or "talking" as cough triggers, a sign for the diagnosis of cough variant asthma.

Authors:  Yoshihiro Kanemitsu; Hisako Matsumoto; Nuriamina Osman; Tsuyoshi Oguma; Tadao Nagasaki; Yumi Izuhara; Isao Ito; Tomoko Tajiri; Toshiyuki Iwata; Akio Niimi; Michiaki Mishima
Journal:  Respir Investig       Date:  2016-08-24

Review 4.  Enhanced Recovery After Surgery: Economic Impact and Value.

Authors:  Lawrence Lee; Liane S Feldman
Journal:  Surg Clin North Am       Date:  2018-08-24       Impact factor: 2.741

5.  Pronator quadratus repair with a part of the brachioradialis muscle insertion in volar plate fixation of distal radius fractures: a prospective randomised trial.

Authors:  Bernd Hohendorff; C Knappwerth; J Franke; L P Müller; C Ries
Journal:  Arch Orthop Trauma Surg       Date:  2018-07-30       Impact factor: 3.067

6.  Factors associated with the decision for operative versus conservative treatment of displaced distal radius fractures in the elderly.

Authors:  Yao-Sen Wu; Jie Yang; Lin-Zhen Xie; Jia-Yu Zhang; Xian-Bin Yu; Wei Hu; Hua Chen; Liao-Jun Sun
Journal:  ANZ J Surg       Date:  2019-09-03       Impact factor: 1.872

7.  Distribution of dexamethasone between mother and fetus after maternal administration.

Authors:  J D Funkhouser; K J Peevy; P B Mockridge; E R Hughes
Journal:  Pediatr Res       Date:  1978-11       Impact factor: 3.756

8.  Patient satisfaction after treatment of distal radial fractures in older adults.

Authors:  Kevin C Chung; Sarah E Sasor; Kelly A Speth; Lu Wang; Melissa J Shauver
Journal:  J Hand Surg Eur Vol       Date:  2019-10-04

9.  Fractures of distal radius: an overview.

Authors:  Sanjay Meena; Pankaj Sharma; Abhishek Kumar Sambharia; Ashok Dawar
Journal:  J Family Med Prim Care       Date:  2014 Oct-Dec

10.  Examination of the pronator quadratus muscle during hardware removal procedures after volar plating for distal radius fractures.

Authors:  Jae-Hwi Nho; Hyun Sik Gong; Cheol Ho Song; Seung Myung Wi; Young Ho Lee; Goo Hyun Baek
Journal:  Clin Orthop Surg       Date:  2014-08-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.