Assessment of respirator fit capability test criteria for full-facepiece air-purifying respirators.

Michael S Bergman1, Ziging Zhuang1, Susan Shuhong Xu1, Samy Rengasamy1, Robert B Lawrence1, Brenda Boutin1, James R Harris1.   

Abstract

An ASTM International subcommittee on Respiratory Protection, F23.65 is currently developing a consensus standard for assessing respirator fit capability (RFC) criteria of half-facepiece air-purifying particulate respirators. The objective of this study was to evaluate if the test methods being developed for half-facepiece respirators can reasonably be applied to nonpowered full-facepiece-air-purifying respirators (FF-APR). Benchmark RFC test data were collected for three families of FF-APRs (a one-size-only family, a two-size family, and a three-size family). All respirators were equipped with P100 class particulate filters. Respirators were outfitted with a sampling probe to collect an in-mask particle concentration sample in the breathing zone of the wearer. Each of the six respirator facepieces was tested on the National Institute for Occupational Safety and Health 25-subject Bivariate Panel. The RFC test assessed face seal leakage using a PortaCount fit test. Subjects followed the corresponding Occupational Safety and Health Administration-accepted fit test protocol. Two donnings per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of subjects in the panel achieving acceptable fit on at least one of two donnings) was determined for each respirator family at specified fit factor passing levels of 500, 1,000, and 2,000. As a reasonable expectation based on a previous analysis of alpha and beta fit test errors for various panel sizes, the selected PPR benchmark for our study was >75%. At the fit factor passing level of 500 obtained on at least one of two donnings, the PPRs for three-, two-, and one-size families were 100, 79, and 88%, respectively. As the fit factor passing criterion increased from 500 to 1,000 or 2,000, PPRs followed a decreasing trend. Each of the three tested families of FF-APRs are capable of fitting ≥75% of the intended user population at the 500 fit factor passing level obtained on at least one of two donnings. The methods presented here can be used as a reference for standards development organizations considering developing RFC test requirements.

Entities:  

Keywords:  Fit test; NIOSH-approved respirator; respirator fit methods

Mesh:

Year:  2019        PMID: 31107187      PMCID: PMC6719699          DOI: 10.1080/15459624.2019.1609006

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  5 in total

1.  Variability in respiratory protection and the assigned protection factor.

Authors:  Mark Nicas; John Neuhaus
Journal:  J Occup Environ Hyg       Date:  2004-02       Impact factor: 2.155

2.  New respirator fit test panels representing the current U.S. civilian work force.

Authors:  Ziqing Zhuang; Bruce Bradtmiller; Ronald E Shaffer
Journal:  J Occup Environ Hyg       Date:  2007-09       Impact factor: 2.155

3.  Determining sample size and a passing criterion for respirator fit-test panels.

Authors:  D Landsittel; Z Zhuang; W Newcomb; R Berry Ann
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

4.  A must for NIOSH: certify fit performance of the half mask particulate respirator.

Authors:  Don J Lofgren
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

5.  Recommended test methods and pass/fail criteria for a respirator fit capability test of half-mask air-purifying respirators.

Authors:  Ziqing Zhuang; Michael Bergman; Zhipeng Lei; George Niezgoda; Ronald Shaffer
Journal:  J Occup Environ Hyg       Date:  2017-06       Impact factor: 2.155

  5 in total
  2 in total

1.  Modified full-face snorkel mask as COVID-19 personal protective equipment: Quantitative results.

Authors:  Kyle Nicholson; Ashley Henke-Adams; Daniel M Henke; Alexxai V Kravitz; Hiram A Gay
Journal:  HardwareX       Date:  2021-02-25

2.  Enclosure with augmented airflow to decrease risk of exposure to aerosolized pathogens including coronavirus during endotracheal intubation. Can the reduction in aerosolized particles be quantified?

Authors:  Jason Bryant; Joseph D Tobias
Journal:  Paediatr Anaesth       Date:  2020-06-25       Impact factor: 2.129

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.