Low Dose and Low Contrast Medium Coronary CT Angiography Using Dual-Layer Spectral Detector CT.

Yan Yi1, Xue-Mei Zhao1, Run-Ze Wu2, Yun Wang1, Mani Vembar2, Zheng-Yu Jin1, Yi-Ning Wang1.   

Abstract

The aim of the present study was to investigate the performance of low keV mono-energetic reconstructions in spectral coronary computed tomography angiography (CCTA) using spectral detector CT (SDCT) with reduced contrast media and radiation dose.Sixty patients were randomly assigned to Groups A and B (both n = 30) to undergo CCTA on a dual-layer SDCT with tube voltage 120 kVp and 100 kVp (average tube current: 108.5 and 73.8 mAs, respectively), with contrast media volume of 36 mL used in both groups. The mono-energetic 40-80 keV and conventional 120 kVp images in Group A and conventional 100 kVp images in Group B were reconstructed. Quantitative and qualitative image quality (IQ) were evaluated in the aortic root and distal segments of the coronary arteries.The patient characteristics were not significantly different between the two groups (all P≥ 0.47), nor was the effective radiation dose (1.5 ± 0.3 and 1.4 ± 0.3 mSv, P = 0.20). The quantitative IQ in aorta and coronary arteries of mono-energetic 40-60 keV was superior to conventional 120 kVp and 100 kVp images (all P < 0.05). The noise in spectral images was lower compared to conventional images (all P < 0.01). The subjective IQ score of 40-50 keV images was not significantly different from that of 100 kVp images (P > 0.8).The mono-energetic 40-50 keV reconstructions from spectral CCTA using SDCT provide improved IQ compared to conventional techniques while facilitating reduced radiation dose and contrast media.

Entities:  

Keywords:  Dual energy computed tomography; Image quality; Mono-energetic reconstruction; Radiation dose; Spectral coronary CT angiography

Mesh:

Substances:

Year:  2019        PMID: 31105142     DOI: 10.1536/ihj.18-340

Source DB:  PubMed          Journal:  Int Heart J        ISSN: 1349-2365            Impact factor:   1.862


  8 in total

1.  Accuracy of virtual monochromatic images generated by the decomposition of photoelectric absorption and Compton scatter in dual-energy computed tomography.

Authors:  Kazuhiro Sato; Chifumi Sato; Ayami Takahashi; Hirokazu Takano; Shingo Kayano; Ayana Ishiguro; Yumi Takane; Tomohiro Kaneta
Journal:  Phys Eng Sci Med       Date:  2022-01-28

2.  What the Baby Formula and Medical Contrast Material Shortages Have in Common: Insights and Recommendations for Managing the Iodinated Contrast Media Shortage.

Authors:  Lakshmi Ananthakrishnan; Fernando U Kay; Eric A Zeikus; Eugene S Chu; Joseph Chang; John D Barr; Neil M Rofsky; Suhny Abbara
Journal:  Radiol Cardiothorac Imaging       Date:  2022-05-25

3.  Incremental improvement of diagnostic performance of coronary CT angiography for the assessment of coronary stenosis in the presence of calcium using a dual-layer spectral detector CT: validation by invasive coronary angiography.

Authors:  Cheng Xu; Yan Yi; Yechen Han; Hongzhi Xie; Xiaomei Lu; Mani Vembar; Tim Leiner; Zhengyu Jin; Yining Wang
Journal:  Int J Cardiovasc Imaging       Date:  2021-06-27       Impact factor: 2.357

4.  Assessment of Virtual Monoenergetic Images in Run-off Computed Tomography Angiography: A Comparison Study to Conventional Images From Spectral Detector Computed Tomography.

Authors:  Haiyan Ren; Yanhua Zhen; Zheng Gong; Chuanzhuo Wang; Zhihui Chang; Jiahe Zheng
Journal:  J Comput Assist Tomogr       Date:  2021 Mar-Apr 01       Impact factor: 2.081

5.  Optimizing low contrast volume thoracic CT angiography: From the basics to the advanced.

Authors:  Katherine Kaproth-Joslin; Susan Hobbs; Prabhakar Rajiah; Apeksha Chaturvedi; Abhishek Chaturvedi
Journal:  J Clin Imaging Sci       Date:  2022-07-29

6.  The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media.

Authors:  Xin Huang; Sizhe Gao; Yue Ma; Xiaomei Lu; Zheng Jia; Yang Hou
Journal:  Quant Imaging Med Surg       Date:  2020-03

7.  Low dose contrast media in step-and-shoot coronary angiography with third-generation dual-source computed tomography: feasibility of using 30 mL of contrast media in patients with body surface area <1.7 m2.

Authors:  Liang Jin; Bing Jie; Yiyi Gao; An'qi Jiang; Tingwen Weng; Ming Li
Journal:  Quant Imaging Med Surg       Date:  2021-06

8.  Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images.

Authors:  David C Rotzinger; Salim A Si-Mohamed; Jérôme Yerly; Sara Boccalini; Fabio Becce; Loïc Boussel; Reto A Meuli; Salah D Qanadli; Philippe C Douek
Journal:  Eur Radiol       Date:  2021-03-19       Impact factor: 5.315

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.