Literature DB >> 31097138

Can Osseointegration Be Achieved Without Primary Stability?

Mohanad Al-Sabbagh1, Walied Eldomiaty2, Yasser Khabbaz3.   

Abstract

The osseointegration and survival of dental implants are linked to primary stability. Good primary stability relies on the mechanical friction between implant surface and surrounding bone with absence of mobility in the osteotomy site immediately after implant placement. Several factors have been found to affect implant primary stability, including bone density, implant design, and surgical technique. Various methods have been used to assess implant primary stability including insertion torque and resonance frequency analysis. This article aims to evaluate the success of osseointegration in the absence of primary stability and to propose recommendations to manage implants that lack primary stability.
Copyright © 2019 Elsevier Inc. All rights reserved.

Keywords:  Bone density; Bone-to-implant contact (BIC); Insertion torque; Osseointegration; Primary stability; Resonance frequency analysis; Secondary stability

Mesh:

Substances:

Year:  2019        PMID: 31097138     DOI: 10.1016/j.cden.2019.02.001

Source DB:  PubMed          Journal:  Dent Clin North Am        ISSN: 0011-8532


  10 in total

1.  Effects of osseodensification protocol on insertion, removal torques, and resonance frequency analysis of BioHorizons® conical implants. An ex vivo study.

Authors:  Felipe Cáceres; Cristian Troncoso; Ramón Silva; Nelson Pinto
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-31

Review 2.  Relationship between dental implant macro-design and osseointegration: a systematic review.

Authors:  Simone Kreve; Izabela Ferreira; Mariana Lima da Costa Valente; Andréa Cândido Dos Reis
Journal:  Oral Maxillofac Surg       Date:  2022-09-29

3.  The Importance of Correlation between CBCT Analysis of Bone Density and Primary Stability When Choosing the Design of Dental Implants-Ex Vivo Study.

Authors:  Mirko Mikic; Zoran Vlahovic; Momir Stevanović; Zoran Arsic; Rasa Mladenovic
Journal:  Tomography       Date:  2022-05-11

4.  Effect of macro-design in the primary stability of short and extra-short implants using resonance frequency analysis. An ex vivo study.

Authors:  Ramón Silva; Pablo Villalón; Felipe Cáceres
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-29

5.  Temporal Changes in Reverse Torque of Locking-Head Screws Used in the Locking Plate in Segmental Tibial Defect in Goat Model.

Authors:  Remigiusz M Grzeskowiak; Rebecca E Rifkin; Elizabeth G Croy; Richard C Steiner; Reza Seddighi; Pierre-Yves Mulon; Henry S Adair; David E Anderson
Journal:  Front Surg       Date:  2021-04-27

6.  Selective Laser Melting and Electron Beam Melting of Ti6Al4V for Orthopedic Applications: A Comparative Study on the Applied Building Direction.

Authors:  Paola Ginestra; Rosalba Monica Ferraro; Keren Zohar-Hauber; Andrea Abeni; Silvia Giliani; Elisabetta Ceretti
Journal:  Materials (Basel)       Date:  2020-12-07       Impact factor: 3.623

7.  Evaluation of the implant diameter on the initial-stability of narrow- and standard-diameter implants placed in simulated Type-I and Type-IV bone-blocks.

Authors:  Saad Alresayes; Sameer A Mokeem; Aasem M Alhenaki; Fahim Vohra; Tariq Abduljabbar
Journal:  Pak J Med Sci       Date:  2021 May-Jun       Impact factor: 1.088

8.  Implant Stability Changes for Nonsubmerged and Submerged Protocols for a Single Implant Mandibular Overdenture Using Ball Attachment.

Authors:  Ahmed Salah; Karim Foda; Mohamed Farouk Abdalla; Marwa Abdel Aal; Amr Naguib; Nouran Abdel Nabi
Journal:  Int J Dent       Date:  2021-09-16

9.  Effect of cyclic loading on the stability of screws placed in the locking plates used to bridge segmental bone defects.

Authors:  Remigiusz M Grzeskowiak; Laura R Freeman; David P Harper; David E Anderson; Pierre-Yves Mulon
Journal:  J Orthop Res       Date:  2020-09-09       Impact factor: 3.494

10.  Under-Drilling versus Hybrid Osseodensification Technique: Differences in Implant Primary Stability and Bone Density of the Implant Bed Walls.

Authors:  Rafael Delgado-Ruiz; Joshua Gold; Tanya Somohano Marquez; Georgios Romanos
Journal:  Materials (Basel)       Date:  2020-01-15       Impact factor: 3.623

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.