Literature DB >> 31096212

Frame versus Frameless Leksell Stereotactic Radiosurgery.

L Dade Lunsford1, Ajay Niranjan2, Kevin Fallon3, Jong Oh Kim3.   

Abstract

For more than 65 years localization of brain targets suitable for stereotactic radiosurgery has been performed after application of an intracranial guiding device to the cranial vault. After imaging and dose planning the same frame is used to secure the target at the focus of the intersection of the ionizing radiation beams that create the radiobiological effect. Non-invasive immobilization systems first proposed for linear accelerator or proton radiation technologies have now been developed for the Leksell Gamma Knife ICON radiosurgical system. The ICON technology adds a cone-beam computed tomography (CBCT) scan to the original Perfexion radiosurgical device in order to define the brain stereotactic space. Marketed since 2015, the ICON can be used for standard radiosurgical procedures, most of which remain frame based, but also coupled with a non-invasive thermoplastic mask for carefully selected patients who undergo standard single-session radiosurgical procedures, as well as multisession procedures using repeat mask fixation. Both at UPMC as well as worldwide, mask immobilization has to date been used for approximately 10% of patients with specific characteristics: relatively simple dose plans, short radiation delivery times, and non-anxious patients, most of whom have metastatic or primary brain cancers. In certain cases, multisession radiosurgery is also performed using the mask. The workflow of frame versus frameless procedures is often altered, and is reliant on high-definition imaging, mostly MRI, done prior to dose planning. Since each CBCT takes 10-12 min to set up and acquire, co-register, and review with the treatment plan, and two CBCT scans are necessary to initiate the treatment plan, this workflow must be added to the beam on time. Although frame-based immobilization remains the predominant method to secure target fixation for problems suitable for single-session radiosurgery, the advent of a mask immobilization technique has proven valuable for a select group of patients. It also provides a non-invasive method to perform multisession or fractionated radiation in patients for whom traditional single-session radiosurgery is not feasible.
© 2019 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2019        PMID: 31096212     DOI: 10.1159/000493046

Source DB:  PubMed          Journal:  Prog Neurol Surg        ISSN: 0079-6492


  8 in total

1.  Discrepancies between frame- and CBCT-based stereotactic space definition on the Gamma Knife Icon.

Authors:  Irina I Bannikova; Aleksandra V Dalechina; Valery V Kostjuchenko; Anjelika E ZHuravleva; Andrey V Golanov; Sergey M Banov; Ivan K Osinov; Aleksandr N Savateev
Journal:  J Appl Clin Med Phys       Date:  2022-05-30       Impact factor: 2.243

2.  Predictors of Treatment Interruption During Frameless Gamma Knife Icon Stereotactic Radiosurgery.

Authors:  Rodney E Wegner; Linda Xu; Zachary Horne; Alexander Yu; Matthew Goss; Yun Liang; Jason Sohn; Stephen M Karlovits
Journal:  Adv Radiat Oncol       Date:  2020-07-01

3.  Adaptation of a Gamma Knife Icon stereotactic radiosurgery program in the face of the COVID-19 pandemic.

Authors:  Rodney E Wegner; Zachary D Horne; Linda Xu; Alexander Yu; Matthew Goss; Yun Liang; Jason Sohn; Athanasios Colonias; Russell Fuhrer; Stephen M Karlovits
Journal:  J Radiosurg SBRT       Date:  2020

4.  Single Fraction Frameless Stereotactic Radiosurgery on the Gamma Knife Icon for Patients With Brain Metastases: Time to Abandon the Frame?

Authors:  Rodney E Wegner; Zachary D Horne; Yun Liang; Matthew Goss; Alexander Yu; Jonathan Pace; Richard W Williamson; Jody Leonardo; Stephen M Karlovits; Russel Fuhrer
Journal:  Adv Radiat Oncol       Date:  2021-06-06

5.  Zero Setup Margin Mask versus Frame Immobilization during Gamma Knife® Icon™ Stereotactic Radiosurgery for Brain Metastases.

Authors:  Tugce Kutuk; Rupesh Kotecha; Ranjini Tolakanahalli; D Jay J Wieczorek; Yongsook C Lee; Manmeet S Ahluwalia; Matthew D Hall; Michael W McDermott; Haley Appel; Alonso N Gutierrez; Minesh P Mehta; Martin C Tom
Journal:  Cancers (Basel)       Date:  2022-07-13       Impact factor: 6.575

6.  Retrospective Analysis of Treatment Workflow in Frame-Based and Frameless Gamma Knife Radiosurgery.

Authors:  Jian Liu; Anuj Goenka; Emel Calugaru; Jameson Baker; Yijian Cao; Michael Schulder; Jenghwa Chang
Journal:  Cureus       Date:  2022-08-30

7.  Intracranial motion during frameless Gamma-Knife stereotactic radiosurgery.

Authors:  Danushka S Seneviratne; Laura A Vallow; Austin Hadley; Timothy D Malouff; William C Stross; Steven Herchko; Deanna H Pafundi; Daniel M Trifiletti; Jennifer L Peterson
Journal:  J Radiosurg SBRT       Date:  2020

8.  Safety Checklist for Gamma Knife Radiosurgery.

Authors:  Nishanth Sadashiva; Manjul Tripathi
Journal:  Asian J Neurosurg       Date:  2019-11-25
  8 in total