Rickey E Carter1, David R Holmes2, Joel G Fletcher3, Cynthia H McCollough3. 1. Department of Health Sciences Research, Mayo Clinic, 4500 San Pablo Road South, Jacksonville, FL 32224. Electronic address: carter.rickey@mayo.edu. 2. Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota. 3. Department of Radiology, Mayo Clinic, Rochester, Minnesota.
Abstract
RATIONALE AND OBJECTIVES: To examine the ability of a pseudoreader study design to estimate the observer performance obtained using a traditional fully crossed, multireader, multicase (MRMC) study. MATERIALS AND METHODS: A 10-reader MRMC study with 20 computed tomography datasets was designed to measure observer performance on four novel noise reduction methods. This study served as the foundation for the empirical evaluation of three different pseudoreader designs, each of which used a similar bootstrap approach for generating 2000 realizations from the fully crossed study. Our three approaches to generating a pseudoreader varied in the degree to which reader performance was matched and integrated into the pseudoreader design. One randomly selected simulation was selected as a "mock study" to represent a hypothetical, prospective implementation of the design. RESULTS: Using the traditional fully crossed design, figures of merit) (95% CIs) for the four noise reductions methods were 68.2 (55.5-81.0), 69.6 (58.4-80.8), 70.8 (60.2-81.4), and 70.9 (60.4-81.3), respectively. When radiologists' performances on the fourth noise reduction method were used to pair readers during the mock study, there was strong agreement in the estimated figures of merits with estimates using the pseudoreader design being within ±3% of the fully crossed design. CONCLUSION: Fully crossed MRMC studies require significant investment in resources and time, often resulting in delayed implementation or minimal human testing before dissemination. The pseudoreader approach accelerates study conduct by combining readers judiciously and was found to provide comparable results to the traditional fully crossed design by making strong assumptions about exchangeability of the readers.
RATIONALE AND OBJECTIVES: To examine the ability of a pseudoreader study design to estimate the observer performance obtained using a traditional fully crossed, multireader, multicase (MRMC) study. MATERIALS AND METHODS: A 10-reader MRMC study with 20 computed tomography datasets was designed to measure observer performance on four novel noise reduction methods. This study served as the foundation for the empirical evaluation of three different pseudoreader designs, each of which used a similar bootstrap approach for generating 2000 realizations from the fully crossed study. Our three approaches to generating a pseudoreader varied in the degree to which reader performance was matched and integrated into the pseudoreader design. One randomly selected simulation was selected as a "mock study" to represent a hypothetical, prospective implementation of the design. RESULTS: Using the traditional fully crossed design, figures of merit) (95% CIs) for the four noise reductions methods were 68.2 (55.5-81.0), 69.6 (58.4-80.8), 70.8 (60.2-81.4), and 70.9 (60.4-81.3), respectively. When radiologists' performances on the fourth noise reduction method were used to pair readers during the mock study, there was strong agreement in the estimated figures of merits with estimates using the pseudoreader design being within ±3% of the fully crossed design. CONCLUSION: Fully crossed MRMC studies require significant investment in resources and time, often resulting in delayed implementation or minimal human testing before dissemination. The pseudoreader approach accelerates study conduct by combining readers judiciously and was found to provide comparable results to the traditional fully crossed design by making strong assumptions about exchangeability of the readers.
Authors: Joel G Fletcher; Mei-Hsiu Chen; Benjamin A Herman; C Daniel Johnson; Alicia Toledano; Abraham H Dachman; Amy K Hara; Jeff L Fidler; Christine O Menias; Kevin J Coakley; Mark Kuo; Karen M Horton; Jugesh Cheema; Revathy Iyer; Bettina Siewert; Judy Yee; Richard Obregon; Peter Zimmerman; Robert Halvorsen; Giovanna Casola; Martina Morrin Journal: AJR Am J Roentgenol Date: 2010-07 Impact factor: 3.959
Authors: Cynthia H McCollough; Adam C Bartley; Rickey E Carter; Baiyu Chen; Tammy A Drees; Phillip Edwards; David R Holmes; Alice E Huang; Farhana Khan; Shuai Leng; Kyle L McMillan; Gregory J Michalak; Kristina M Nunez; Lifeng Yu; Joel G Fletcher Journal: Med Phys Date: 2017-10 Impact factor: 4.071
Authors: Joel G Fletcher; Jeff L Fidler; Sudhakar K Venkatesh; David M Hough; Naoki Takahashi; Lifeng Yu; Matthew Johnson; Shuai Leng; David R Holmes; Rickey Carter; Cynthia H McCollough Journal: Radiology Date: 2018-09-11 Impact factor: 11.105
Authors: Taylor R Moen; Baiyu Chen; David R Holmes; Xinhui Duan; Zhicong Yu; Lifeng Yu; Shuai Leng; Joel G Fletcher; Cynthia H McCollough Journal: Med Phys Date: 2020-12-16 Impact factor: 4.071