Ultraclean air systems and the claim that laminar airflow systems fail to prevent deep infections after total joint arthroplasty.

W Whyte1, B Lytsy2.   

Abstract

The World Health Organization published guidelines in 2016 for preventing surgical site infections. The guidelines contained a conditional recommendation that laminar airflow (LAF) ventilation systems should not be used to reduce the risk of infection after total joint arthroplasty (TJA). This recommendation was largely based on a systematic review and meta-analysis of information from hospital infection surveillance registries. The recommendation contradicts information published in earlier major studies carried out by Charnley and the UK Medical Research Council (MRC). The first aim of this article is to revisit and explain the MRC study, and reply to criticisms of it. The second aim is to suggest reasons why some recent studies have failed to demonstrate that ultraclean air (UCA) systems reduce deep joint infection after TJA. It demonstrates that if a UCA system establishes average airborne concentrations of microbe-carrying particles (MCPs) <10/m3, and preferably <1/m3, then deep joint infection after TJA will be lower than in conventionally ventilated operating theatres.
Copyright © 2019 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Laminar airflow (LAF); Surgical infections; Total joint arthroplasty; Ultraclean air

Mesh:

Year:  2019        PMID: 31059724     DOI: 10.1016/j.jhin.2019.04.021

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  3 in total

1.  Atti del 52° Congresso Nazionale: Società Italiana di Igiene, Medicina Preventiva e Sanità Pubblica (SItI).

Authors: 
Journal:  J Prev Med Hyg       Date:  2019-10-15

2.  Infection prevention and control considerations regarding ventilation in acute hospitals.

Authors:  Hilary Humphreys
Journal:  Infect Prev Pract       Date:  2021-10-20

3.  The Influence of Surgical Staff Behavior on Air Quality in a Conventionally Ventilated Operating Theatre during a Simulated Arthroplasty: A Case Study at the University Hospital of Parma.

Authors:  Cesira Pasquarella; Carla Balocco; Maria Eugenia Colucci; Elisa Saccani; Samuel Paroni; Lara Albertini; Pietro Vitali; Roberto Albertini
Journal:  Int J Environ Res Public Health       Date:  2020-01-10       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.