Literature DB >> 31056520

Low-Cost Haptic Simulation Using Material Fracture.

David F Pepley, Hong-En Chen, Yichun Tang, Sanjib Das Adhikary, Scarlett R Miller, Jason Z Moore.   

Abstract

Medical simulation training is widely used to effectively train for invasive medical procedures such as peripheral nerve blocks. Traditionally, accurate haptic training relies on expensive cadavers, manikins, or advanced haptic robots. Proposed herein is a novel concept for haptic training called the low-cost haptic force needle insertion simulator (LCNIS), which uses material fracture inside disposable cartridges to accurately replicate the force of inserting a needle into tissue. Cadaver and material fracture experiments were performed to develop and determine the accuracy of the LCNIS. The material testing showed that polycarbonate had the highest maximum needle puncture force of the materials tested, 9.85 N, and that fluorinated ethylene propylene had the lowest maximum puncture force, 0.84 N. The cadaver results showed that the error between the three peak forces in a cadaver and a cadaver mimicking cartridge was 1.00 N, 0.01 N, and 1.54 N. The standard deviation of these peaks was 0.60 N, 0.55 N, and 0.41 N. This novel method of haptic simulation can easily be adapted to recreate any type of force and, therefore, could be utilized to train for a wide variety of medical procedures.

Entities:  

Mesh:

Year:  2019        PMID: 31056520      PMCID: PMC6944059          DOI: 10.1109/TOH.2019.2914441

Source DB:  PubMed          Journal:  IEEE Trans Haptics        ISSN: 1939-1412            Impact factor:   2.487


  30 in total

1.  The use of electromagnetic motion tracking analysis to objectively measure open surgical skill in the laboratory-based model.

Authors:  V Datta; S Mackay; M Mandalia; A Darzi
Journal:  J Am Coll Surg       Date:  2001-11       Impact factor: 6.113

2.  Teaching the surgical craft: From selection to certification.

Authors:  Kyle R Wanzel; Mylène Ward; Richard K Reznick
Journal:  Curr Probl Surg       Date:  2002-06       Impact factor: 1.909

3.  A novel and inexpensive ballistic gel phantom for ultrasound training.

Authors:  Richard Amini; Jeffrey Z Kartchner; Lori A Stolz; David Biffar; Allan J Hamilton; Srikar Adhikari
Journal:  World J Emerg Med       Date:  2015

4.  An assessment tool for brachial plexus regional anesthesia performance: establishing construct validity and reliability.

Authors:  Viren N Naik; Anahi Perlas; Deven B Chandra; David Y Chung; Vincent W S Chan
Journal:  Reg Anesth Pain Med       Date:  2007 Jan-Feb       Impact factor: 6.288

5.  Characterizing novice behavior associated with learning ultrasound-guided peripheral regional anesthesia.

Authors:  Brian D Sites; Brian C Spence; John D Gallagher; Christopher W Wiley; Marc L Bertrand; George T Blike
Journal:  Reg Anesth Pain Med       Date:  2007 Mar-Apr       Impact factor: 6.288

6.  Changes in anesthesia-related factors in ambulatory knee and shoulder surgery: United States 1996-2006.

Authors:  Stavros G Memtsoudis; Cassie Kuo; Yan Ma; Alison Edwards; Madhu Mazumdar; Gregory Liguori
Journal:  Reg Anesth Pain Med       Date:  2011 Jul-Aug       Impact factor: 6.288

7.  Research opportunities in simulation-based medical education using deliberate practice.

Authors:  William C McGaghie
Journal:  Acad Emerg Med       Date:  2008-09-22       Impact factor: 3.451

8.  Who should teach medical students surgery?

Authors:  L A Neumayer; A K Sachdeva; J C Hebert; N P Lang
Journal:  Am J Surg       Date:  1997-03       Impact factor: 2.565

Review 9.  Neurological complications after regional anesthesia: contemporary estimates of risk.

Authors:  Richard Brull; Colin J L McCartney; Vincent W S Chan; Hossam El-Beheiry
Journal:  Anesth Analg       Date:  2007-04       Impact factor: 5.108

10.  Validation of the imperial college surgical assessment device for spinal anesthesia.

Authors:  Marcia A Corvetto; Carlos Fuentes; Andrea Araneda; Pablo Achurra; Pablo Miranda; Paola Viviani; Fernando R Altermatt
Journal:  BMC Anesthesiol       Date:  2017-09-29       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.