Literature DB >> 31039549

Acoustic radiation force imaging using a single-shot spiral readout.

Asaf Ilovitsh1, Brett Z Fite, Tali Ilovitsh, Katherine W Ferrara.   

Abstract

The purpose of this study is to develop and validate rapid magnetic resonance acoustic radiation force imaging (MR-ARFI) using a single shot spiral readout for focused ultrasound (FUS) guidance and for local tissue displacement measurements. A magnetic resonance guided FUS system was used to focus a 3 MHz ultrasound beam to a predetermined position. MR-ARFI was performed with a Bruker 7 T MRI using a modified single-shot spiral readout, with additional motion encoding gradients that convert local displacement into the phase image. Post processing was then used to analyze the resulting displacement and to evaluate the method's performance for the detection of tissue changes resulting from thermal ablation. The single-shot spiral readout acquires a single MR-ARFI image in one second, which is up to two orders of magnitude faster than conventional 2D spin-warp spin echo that acquires the k-space data line by line. The ARFI displacement in tissue mimicking phantoms was detected and localized with less than 5% geometric distortion. The ARFI displacement was also measured pre and post thermal ablation in an ex vivo chicken breast. For transmitted peak negative pressure of 8.6 MPa, the maximum displacement of the tissue that was ablated to 70 °C was 78% lower than the pre-ablated tissue. Since spiral readout is not prone to geometrical distortion, it is well-suited for FUS guidance, without generating undesired temperature elevation. Additionally, local displacement measurements of tissues can be performed rapidly during thermal ablation procedures and may help to assess the success of the treatment.

Entities:  

Mesh:

Year:  2019        PMID: 31039549      PMCID: PMC6800020          DOI: 10.1088/1361-6560/ab1e21

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  43 in total

1.  Improvements in spiral MR imaging.

Authors:  P Börnert; H Schomberg; B Aldefeld; J Groen
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

2.  Magnetic resonance acoustic radiation force imaging.

Authors:  Nathan McDannold; Stephan E Maier
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

3.  MR acoustic radiation force imaging: in vivo comparison to ultrasound motion tracking.

Authors:  Yuexi Huang; Laura Curiel; Aleksandra Kukic; Donald B Plewes; Rajiv Chopra; Kullervo Hynynen
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

4.  Spiral K-space MR imaging of cortical activation.

Authors:  D C Noll; J D Cohen; C H Meyer; W Schneider
Journal:  J Magn Reson Imaging       Date:  1995 Jan-Feb       Impact factor: 4.813

5.  Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI.

Authors:  Bertram J Wilm; Christoph Barmet; Simon Gross; Lars Kasper; S Johanna Vannesjo; Max Haeberlin; Benjamin E Dietrich; David O Brunner; Thomas Schmid; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2016-10-21       Impact factor: 4.668

6.  Real-time magnetic resonance-guided high-intensity focused ultrasound focal therapy for localised prostate cancer: preliminary experience.

Authors:  Alessandro Napoli; Michele Anzidei; Cosimo De Nunzio; Gaia Cartocci; Valeria Panebianco; Carlo De Dominicis; Carlo Catalano; Federico Petrucci; Costantino Leonardo
Journal:  Eur Urol       Date:  2012-11-12       Impact factor: 20.096

7.  MR-ARFI-based method for the quantitative measurement of tissue elasticity: application for monitoring HIFU therapy.

Authors:  Jonathan Vappou; Pierre Bour; Fabrice Marquet; Valery Ozenne; Bruno Quesson
Journal:  Phys Med Biol       Date:  2018-05-04       Impact factor: 3.609

8.  Rapid MR-ARFI method for focal spot localization during focused ultrasound therapy.

Authors:  Elena A Kaye; Jing Chen; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2010-11-16       Impact factor: 4.668

9.  Comparison of temperature processing methods for monitoring focused ultrasound ablation in the brain.

Authors:  Viola Rieke; Ron Instrella; Jarrett Rosenberg; William Grissom; Beat Werner; Ernst Martin; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2013-04-04       Impact factor: 4.813

10.  Concurrent Visualization of Acoustic Radiation Force Displacement and Shear Wave Propagation with 7T MRI.

Authors:  Yu Liu; Brett Z Fite; Lisa M Mahakian; Sarah M Johnson; Benoit Larrat; Erik Dumont; Katherine W Ferrara
Journal:  PLoS One       Date:  2015-10-06       Impact factor: 3.240

View more
  2 in total

1.  Improving in situ acoustic intensity estimates using MR acoustic radiation force imaging in combination with multifrequency MR elastography.

Authors:  Ningrui Li; Pooja Gaur; Kristin Quah; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2022-06-28       Impact factor: 3.737

2.  A Review of Imaging Methods to Assess Ultrasound-Mediated Ablation.

Authors:  Brett Z Fite; James Wang; Pejman Ghanouni; Katherine W Ferrara
Journal:  BME Front       Date:  2022-05-02
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.