Literature DB >> 31020788

VitaFlow™ transcatheter valve system in the treatment of severe aortic stenosis: One-year results of a multicenter study.

Daxin Zhou1, Wenzhi Pan1, Jianan Wang2, Yongjian Wu3, Mao Chen4, Thomas Modine5, Darren Mylotte6, Niccolo Piazza7, Junbo Ge1.   

Abstract

OBJECTIVE: This study reports the 1-year clinical outcomes of the VitaFlow™ transcatheter aortic valve system in the treatment of severe aortic stenosis.
BACKGROUND: The VitaFlow™ system (MicroPort®, Shanghai, China) was developed as a novel transcatheter aortic valve replacement system to mitigate or circumvent some of the challenges associated with heavily calcified valves and bicuspid valves.
METHODS: From September 2014 to November 2017, a prospective, multicenter, single arm study was conducted in 11 centers in China. The primary end point was all cause mortality at 12 months.
RESULTS: One hundred and ten symptomatic aortic stenosis patients (60 men, 50 women; mean age 77.73 ± 4.78 years) at prohibitive or high risk for surgery were enrolled. Mean society of thoracic surgeons score was 8.84 ± 5.58%. All-cause mortality was 2.7% at 1-year. Major stroke, major vascular complication, coronary artery obstruction, new pacemaker implantation occurred in 2.7, 2.7, 1.8, and 19.1% at 1-year follow-up, respectively. No patients had moderate or severe paravalvular leak at 1-year. At 1 year follow-up, 97% of patients had New York heart association ≤II. Patients with bicuspid valves had similar outcomes as those patients with tricuspid aortic valve stenosis.
CONCLUSIONS: The 12-month clinical results support the safety and efficacy of VitaFlow™ in the treatment of patients with severe aortic stenosis, including patients with bicuspid aortic valve.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic stenosis; bicuspid aortic valve; self-expanding; transcatheter aortic valve replacement

Year:  2019        PMID: 31020788     DOI: 10.1002/ccd.28226

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  11 in total

1.  Treating patients with excessively large annuli with self-expanding transcatheter aortic valves: insights into supra-annular structures that anchor the prosthesis.

Authors:  Tian-Yuan Xiong; Yan-Biao Liao; Yi-Jian Li; Fei Chen; Yuanweixiang Ou; Xi Wang; Zi-Jie Wang; Xi Li; Zhen-Gang Zhao; Wei Meng; Yuan Feng; Mao Chen
Journal:  Herz       Date:  2020-09-03       Impact factor: 1.443

Review 2.  Transcatheter aortic valve implantation in patients with bicuspid valve morphology: a roadmap towards standardization.

Authors:  Tian-Yuan Xiong; Walid Ben Ali; Yuan Feng; Kentaro Hayashida; Hasan Jilaihawi; Azeem Latib; Michael Kang-Yin Lee; Martin B Leon; Raj R Makkar; Thomas Modine; Christoph Naber; Yong Peng; Nicolo Piazza; Michael J Reardon; Simon Redwood; Ashok Seth; Lars Sondergaard; Edgar Tay; Didier Tchetche; Wei-Hsian Yin; Mao Chen; Bernard Prendergast; Darren Mylotte
Journal:  Nat Rev Cardiol       Date:  2022-06-20       Impact factor: 32.419

3.  A single-center analysis of outcomes, risk factors, and new valves in Asian patients treated with early transcatheter aortic valve implantation.

Authors:  Ying Liang; Wei Wang; Xu Wang; Feilong Hei; Yulong Guan
Journal:  Cardiovasc Diagn Ther       Date:  2021-08

4.  Short- and Long-Term Outcome after Emergent Cardiac Surgery during Transcatheter Aortic Valve Implantation.

Authors:  Fei Li; Xu Wang; Yuetang Wang; Xuan Li; Shihua Zhao; Yongjian Wu; Wei Wang
Journal:  Ann Thorac Cardiovasc Surg       Date:  2021-01-15       Impact factor: 1.520

5.  Coronary protection for the small left coronary sinus during transcatheter aortic valve replacement: a case report.

Authors:  Chen Yang; Guangyuan Song; Guannan Niu; Yongjian Wu
Journal:  Eur Heart J Case Rep       Date:  2022-01-24

6.  Propensity-matched comparison of balloon-expandable and self-expanding valves for transcatheter aortic valve replacement in a Chinese population.

Authors:  Wen-Bin Ou-Yang; Wei Wang; Jie Dong; Yong-Quan Xie; Jun-Yi Wan; Zi-Qi Yue; Shou-Zheng Wang; Hong Meng; Xu Wang; Dong-Hui Xu; Feng-Wen Zhang; Jing Dong; Xiang-Bin Pan; Ge-Jun Zhang
Journal:  Ann Transl Med       Date:  2022-01

7.  Comparative Quantitative Aortographic Assessment of Regurgitation in Patients Treated With VitaFlow Transcatheter Heart Valve vs. Other Self-Expanding Systems.

Authors:  Rutao Wang; Hideyuki Kawashima; Chao Gao; Fangjun Mou; Ping Li; Junjie Zhang; Jian Yang; Jianfang Luo; Darren Mylotte; William Wijns; Yoshinobu Onuma; Osama Soliman; Ling Tao; Patrick W Serruys
Journal:  Front Cardiovasc Med       Date:  2022-01-25

Review 8.  An Update on New Generation Transcatheter Aortic Valves and Delivery Systems.

Authors:  Gloria Santangelo; Alfonso Ielasi; Mariano Pellicano; Azeem Latib; Maurizio Tespili; Francesco Donatelli
Journal:  J Clin Med       Date:  2022-01-19       Impact factor: 4.241

9.  Patients With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Yi Zhang; Tian-Yuan Xiong; Yi-Ming Li; Yi-Jun Yao; Jing-Jing He; Hao-Ran Yang; Zhong-Kai Zhu; Fei Chen; Yuanweixiang Ou; Xi Wang; Qi Liu; Xi Li; Yi-Jian Li; Yan-Biao Liao; Fang-Yang Huang; Zhen-Gang Zhao; Qiao Li; Xin Wei; Yong Peng; Sen He; Jia-Fu Wei; Wen-Xia Zhou; Ming-Xia Zheng; Yun Bao; Xuan Zhou; Hong Tang; Wei Meng; Yuan Feng; Mao Chen
Journal:  Front Cardiovasc Med       Date:  2022-03-16

Review 10.  Evolving Devices and Material in Transcatheter Aortic Valve Replacement: What to Use and for Whom.

Authors:  Mauro Chiarito; Alessandro Spirito; Johny Nicolas; Alexandra Selberg; Giulio Stefanini; Antonio Colombo; Bernhard Reimers; Annapoorna Kini; Samin K Sharma; George D Dangas; Roxana Mehran
Journal:  J Clin Med       Date:  2022-07-30       Impact factor: 4.964

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.