Literature DB >> 31020411

Histological score for degrees of severity in an implant-associated infection model in mice.

Carina Büren1, Michael Hambüchen2, Joachim Windolf3, Tim Lögters4, Ceylan Daniela Windolf3.   

Abstract

INTRODUCTION: Several scores were introduced to diagnose and to classify osteomyelitis in practice. Mouse models are often used to study the pathophysiology of bone infection and to test therapeutic strategies. Aim of the present study was to design a score to diagnose and quantify implant-associated infection in a murine experimental model.
MATERIALS AND METHODS: Four independent parameters were developed: existence of callus, consolidation of the fracture, structural changes of the medullary cavity and number of bacteria. The score was assessed in a standardized implant-associated mouse model with 35 BALB/c-mice. The left femur was osteotomized, fixed by a titanium locking plate and infection was induced by inoculation of Staphylococcus aureus into the fracture gap. For the sham group, the procedure was performed without inoculation of bacteria. The score was assessed on days 7, 14 and 28. Each item of the score showed lower values for the infection group compared to the controls after 4 weeks.
RESULTS: Regardless of the assessed time point, the overall total score was significantly higher in the control group compared to the infection group (p < 0.0001). Analysis revealed a sensitivity of 0.85, specificity of 1.0, negative predictive value of 0.67 and positive predictive value of 1.0.
CONCLUSION: The proposed score assessing severity of fracture-related infection in an implant-associated murine model was easy to access, feasible to diagnose and estimate bone healing and infection in a murine bone infection with a high sensitivity. Therefore, this score might be a useful tool to quantify infection-related changes after fracture in further future preclinical studies.

Entities:  

Keywords:  Fracture-related infection; Mouse model; Score; Staphylococcus aureus

Mesh:

Year:  2019        PMID: 31020411     DOI: 10.1007/s00402-019-03188-6

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  4 in total

Review 1.  A comprehensive review of mouse diaphyseal femur fracture models.

Authors:  Zachary J Gunderson; Zachery R Campbell; Todd O McKinley; Roman M Natoli; Melissa A Kacena
Journal:  Injury       Date:  2020-04-18       Impact factor: 2.586

2.  Comparative diagnostic accuracy of respective nuclear imaging for suspected fracture-related infection: a systematic review and Bayesian network meta-analysis.

Authors:  Qingyu Zhang; Jinlei Dong; Yelong Shen; Canhua Yun; Dongsheng Zhou; Fanxiao Liu
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-08       Impact factor: 3.067

3.  mRNA Transcriptome Analysis of Bone in a Mouse Model of Implant-Associated Staphylococcus aureus Osteomyelitis.

Authors:  Yihuang Lin; Jianwen Su; Yutian Wang; Daorong Xu; Xianrong Zhang; Bin Yu
Journal:  Infect Immun       Date:  2021-04-16       Impact factor: 3.441

Review 4.  A systematic review on current osteosynthesis-associated infection animal fracture models.

Authors:  Ronald M Y Wong; Tsz-Kiu Li; Jie Li; Wing-Tung Ho; Simon K-H Chow; Sharon S Y Leung; Wing-Hoi Cheung; Margaret Ip
Journal:  J Orthop Translat       Date:  2020-03-30       Impact factor: 5.191

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.