Literature DB >> 31014572

CT-guided core needle biopsy of small (≤20 mm) subpleural pulmonary lesions: value of the long transpulmonary needle path.

J H Yu1, B Li2, X X Yu2, Y Du2, H F Yang2, X X Xu2, C Zhang2, Y Li3.   

Abstract

AIM: To evaluate the accuracy and complications of computed tomography (CT)-guided core needle biopsy (CNB) of small (≤20 mm) subpleural pulmonary lesions with the use of the long transpulmonary needle path.
MATERIALS AND METHODS: A retrospective study was undertaken comprising 235 patients who underwent CT-guided CNB of small (≤20 mm) subpleural pulmonary lesions. One of two needle paths was used: a long (≥10 mm) transpulmonary needle path (n=164, group A) or a short (<10 mm) transpulmonary needle path (n=71, group B). Diagnostic accuracy, pneumothorax, and bleeding rates were compared between the two groups.
RESULTS: The diagnostic accuracy in group A was significantly higher than that in group B (93.9% versus 81.7%, p=0.004), particularly in patients with 5-10 mm lesions (89.2% versus 53.3%, p=0.013). The mean length of the transpulmonary needle path was 23.9 mm in group A and 5.9 mm in group B (p<0.001). The mean number of pleural punctures in group A was 1.01 and 1.11 in group B (p=0.016), but for patients with more than one puncture, the short transpulmonary path was not associated with a higher accuracy rate. The incidence of bleeding was 22% in group A and 9.9% in group B (p=0.028).
CONCLUSION: Diagnostic accuracy for small subpleural pulmonary lesions with the use of the long transpulmonary needle path was higher than that with the use of the short transpulmonary needle path, especially for 5-10 mm lesions; however, the long transpulmonary needle path was associated with a higher rate of bleeding.
Copyright © 2019. Published by Elsevier Ltd.

Entities:  

Mesh:

Year:  2019        PMID: 31014572     DOI: 10.1016/j.crad.2019.03.019

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  2 in total

1.  Small (≤ 20 mm) ground-glass opacity pulmonary lesions: which factors influence the diagnostic accuracy of CT-guided percutaneous core needle biopsy?

Authors:  Yang Li; Chao Feng Yang; Jun Peng; Bing Li; Chuan Zhang; Jin Hong Yu
Journal:  BMC Pulm Med       Date:  2022-07-07       Impact factor: 3.320

2.  Supplementary benefits of CT-guided transthoracic lung aspiration biopsy for core needle biopsy.

Authors:  Jia-Huan He; Jia-Xing Ruan; Ying Lei; Zhi-Dan Hua; Xiang Chen; Da Huang; Cheng-Shui Chen; Xu-Ru Jin
Journal:  Front Microbiol       Date:  2022-09-14       Impact factor: 6.064