Literature DB >> 31008429

Direct Observation Assessment of Ultrasound Competency Using a Mobile Standardized Direct Observation Tool Application With Comparison to Asynchronous Quality Assurance Evaluation.

Keith S Boniface1, Kat Ogle1, Ahmad Aalam1, Maxine LeSaux1, Matt Pyle1, Sohaib Mandoorah1,2, Hamid Shokoohi1,3.   

Abstract

OBJECTIVES: Competency assessment is a key component of point-of-care ultrasound (POCUS) training. The purpose of this study was to design a smartphone-based standardized direct observation tool (SDOT) and to compare a faculty-observed competency assessment at the bedside with a blinded reference standard assessment in the quality assurance (QA) review of ultrasound images.
METHODS: In this prospective, observational study, an SDOT was created using SurveyMonkey containing specific scoring and evaluation items based on the Council of Emergency Medicine Residency-Academy of Emergency Ultrasound: Consensus Document for the Emergency Ultrasound Milestone Project. Ultrasound faculty used the mobile phone-based data collection tool as an SDOT at the bedside when students, residents, and fellows were performing one of eight core POCUS examinations. Data recorded included demographic data, examination-specific data, and overall quality measures (on a scale of 1-5, with 3 and above being defined as adequate for clinical decision making), as well as interpretation and clinical knowledge. The POCUS examination itself was recorded and uploaded to QPath, a HIPAA-compliant ultrasound archive. Each examination was later reviewed by another faculty blinded to the result of the bedside evaluation. The agreement of examinations scored adequate (3 and above) in the two evaluation methods was the primary outcome.
RESULTS: A total of 163 direct observation evaluations were collected from 23 EM residents (93 SDOTs [57%]), 14 students (51 SDOTs [31%]), and four fellows (19 SDOTs [12%]). The trainees were evaluated on completing cardiac (54 [33%]), focused assessment with sonography for trauma (34 [21%]), biliary (25 [15%]), aorta (18 [11%]), renal (12 [7%]), pelvis (eight [5%]), deep vein thrombosis (seven [4%]), and lung scan (5 [3%]). Overall, the number of observed agreements between bedside and QA assessments was 81 (87.1% of the observations) for evaluating the quality of images (scores 1 and 2 vs. scores 3, 4, and 5). The strength of agreement is considered to be "fair" (κ = 0.251 and 95% confidence interval [CI] = 0.02-0.48). Further agreement assessment demonstrated a fair agreement for images taken by residents and students and a "perfect" agreement in images taken by fellows. Overall, a "moderate" inter-rater agreement was found in 79.1% for the accuracy of interpretation of POCUS scan (e.g., true positive, false negative) during QA and bedside evaluation (κ = 0.48, 95% CI = 0.34-0.63). Faculty at the bedside and QA assessment reached a moderate agreement on interpretations noted by residents and students and a "good" agreement on fellows' scans.
CONCLUSION: Using a bedside SDOT through a mobile SurveyMonkey platform facilitates assessment of competency in emergency ultrasound learners and correlates well with traditional competency evaluation by asynchronous weekly image review QA.

Entities:  

Year:  2019        PMID: 31008429      PMCID: PMC6457355          DOI: 10.1002/aet2.10324

Source DB:  PubMed          Journal:  AEM Educ Train        ISSN: 2472-5390


  15 in total

1.  American College of Emergency Physicians. Use of ultrasound imaging by emergency physicians.

Authors: 
Journal:  Ann Emerg Med       Date:  2001-10       Impact factor: 5.721

2.  Emergency ultrasound guidelines.

Authors: 
Journal:  Ann Emerg Med       Date:  2009-04       Impact factor: 5.721

3.  CORD-AEUS: consensus document for the emergency ultrasound milestone project.

Authors:  Resa E Lewiss; Michelle Pearl; Jason T Nomura; Gillian Baty; Rimon Bengiamin; Kael Duprey; Michael Stone; Daniel Theodoro; Saadia Akhtar
Journal:  Acad Emerg Med       Date:  2013-07       Impact factor: 3.451

4.  Learning curves in emergency ultrasound education.

Authors:  David J Blehar; Bruce Barton; Romolo J Gaspari
Journal:  Acad Emerg Med       Date:  2015-04-22       Impact factor: 3.451

5.  Ultrasound competency assessment in emergency medicine residency programs.

Authors:  Richard Amini; Srikar Adhikari; Albert Fiorello
Journal:  Acad Emerg Med       Date:  2014-07-08       Impact factor: 3.451

6.  Emergency ultrasound: Leveling the training and assessment landscape.

Authors:  Keith Boniface; Lalena M Yarris
Journal:  Acad Emerg Med       Date:  2014-08-12       Impact factor: 3.451

Review 7.  The 2013 Model of the Clinical Practice of Emergency Medicine.

Authors:  Francis L Counselman; Marc A Borenstein; Carey D Chisholm; Michael L Epter; Sorabh Khandelwal; Chadd K Kraus; Samuel D Luber; Catherine A Marco; Susan B Promes; Gillian Schmitz; Julia N Keehbauch
Journal:  Acad Emerg Med       Date:  2014-05       Impact factor: 3.451

8.  Resident training in emergency ultrasound: consensus recommendations from the 2008 Council of Emergency Medicine Residency Directors Conference.

Authors:  Saadia Akhtar; Dan Theodoro; Romolo Gaspari; Vivek Tayal; Paul Sierzenski; Joseph Lamantia; Sarah Stahmer; Chris Raio
Journal:  Acad Emerg Med       Date:  2009-12       Impact factor: 3.451

9.  Toward Defining the Foundation of the MD Degree: Core Entrustable Professional Activities for Entering Residency.

Authors:  Robert Englander; Timothy Flynn; Stephanie Call; Carol Carraccio; Lynn Cleary; Tracy B Fulton; Maureen J Garrity; Steven A Lieberman; Brenessa Lindeman; Monica L Lypson; Rebecca M Minter; Jay Rosenfield; Joe Thomas; Mark C Wilson; Carol A Aschenbrener
Journal:  Acad Med       Date:  2016-10       Impact factor: 6.893

10.  Ten Tips for Engaging the Millennial Learner and Moving an Emergency Medicine Residency Curriculum into the 21st Century.

Authors:  Shannon L Toohey; Alisa Wray; Warren Wiechmann; Michelle Lin; Megan Boysen-Osborn
Journal:  West J Emerg Med       Date:  2016-05-05
View more
  2 in total

1.  The Ultrasound Competency Assessment Tool (UCAT): Development and Evaluation of a Novel Competency-based Assessment Tool for Point-of-care Ultrasound.

Authors:  Colin Bell; Andrew K Hall; Natalie Wagner; Louise Rang; Joseph Newbigging; Conor McKaigney
Journal:  AEM Educ Train       Date:  2020-10-03

2.  Current Use, Perceived Barriers, and Learning Preference of Point of Care Ultrasound (POCUS) in the Emergency Medicine in Qatar - A Mixed Design.

Authors:  Khalid Bashir; Aftab Mohammad Azad; Ayman Hereiz; Mohammed Talha Bashir; Maarij Masood; Amr Elmoheen
Journal:  Open Access Emerg Med       Date:  2021-05-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.