BACKGROUND: Identification of the cricothyroid membrane is frequently inaccurate in females because of less distinct anatomy compared with males. Supraglottic airway devices cause ventral displacement of the laryngeal structures. We investigated if this would impact on the accuracy of cricothyroid membrane identification using palpation.
METHODS: We recruited 64 adult females who underwent assessment by volunteer participants with and without a sited i-gel® supraglottic airway device. The primary outcome was accuracy in identifying the cricothyroid membrane. Secondary outcomes included distance from participant estimate to actual cricothyroid membrane location and perceived difficulty using a visual analogue scale. Ultrasound images were analysed to determine the effect of the i-gel® on the anatomical structures relevant to cricothyroidotomy.
RESULTS: The cricothyroid membrane was identified correctly in 42/64 subjects with the i-gel® in place (66%) vs 23/64 of controls (36%; P<0.001, mean difference 30%; 95% confidence interval, 12-47%). VAS (P<0.001) and distance to the cricothyroid membrane (P<0.001) decreased in the intervention group. Analysis of the ultrasound image series showed a reduction in the mean angle between the cricothyroid membrane and anterior wall of the trachea in the i-gel® group, because of the more ventral position of the cricoid cartilage compared with control images (166° vs 151°, P<0.001).
CONCLUSIONS: The presence of the i-gel® improved accuracy of identifying the cricothyroid membrane using palpation in females. The cricoid cartilage was pushed ventrally by the i-gel® in the hypopharynx, creating a more palpable prominence. It may therefore be advantageous to retain a sited supraglottic airway, rather than remove it, before performing emergency cricothyroidotomy.
Copyright © 2019 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Difficult Airway Society guidelines; airway management; cricothyroid membrane; cricothyroidotomy; i-gel(®); supraglottic airway device

Mesh:

Year:  2019        PMID: 30987766     DOI: 10.1016/j.bja.2019.03.012

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  2 in total

1.  Evaluation of a novel emergency front of neck access device in a benchtop model of obesity.

Authors:  Sunil K Chauhan; Myles Monaghan; Conan L McCaul
Journal:  Ir J Med Sci       Date:  2021-03-03       Impact factor: 1.568

2.  Effect of different types of laryngeal mask airway placement on the right internal jugular vein: A prospective randomized controlled trial.

Authors:  Jing-Jing Zhang; Zong-Yang Qu; Zhen Hua; Ming-Zhang Zuo; Hong-Ye Zhang
Journal:  World J Clin Cases       Date:  2019-12-26       Impact factor: 1.337

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.