| Literature DB >> 31911905 |
Jing-Jing Zhang1, Zong-Yang Qu1, Zhen Hua1, Ming-Zhang Zuo1, Hong-Ye Zhang2.
Abstract
BACKGROUND: In recent years, with the popularity of laryngeal mask airway (LMA) for the management of clinical anesthesia, the influence of the LMA on the position and blood flow of the internal jugular vein (IJV) has attracted an increasing amount of attention. AIM: To investigate the effect of placement of different types of LMA (Supreme LMA, Guardian LMA, I-gel LMA) on the position and blood flow of the right IJV.Entities:
Keywords: Blood flow; Common carotid artery; Internal jugular vein; Laryngeal mask airway
Year: 2019 PMID: 31911905 PMCID: PMC6940344 DOI: 10.12998/wjcc.v7.i24.4245
Source DB: PubMed Journal: World J Clin Cases ISSN: 2307-8960 Impact factor: 1.337
Figure 1Research flow chart. LMA: Laryngeal mask airway.
Baseline demographics and characteristics
| Gender, Male/Female | 2/30 | 6/33 | 5/24 | 0.342 |
| Age in yr | 50 ± 16 | 49 ± 15 | 49 ± 16 | 0.932 |
| Height in cm | 163 ± 5 | 164 ± 6 | 163 ± 7 | 0.626 |
| BMI in kg/m2 | 23 ± 3 | 23 ± 3 | 23 ± 3 | 0.754 |
| ASA, I/II | 17/15 | 26/13 | 18/11 | 0.503 |
| LMA size, 3/4/5 | 4/27/1 | 3/35/1 | 5/23/1 | 0.807 |
ASA: The American Society of Anesthesiologists; BMI: Body mass index; LMA: Laryngeal mask airway.
Overlap index
| High point | ||||
| Before LMA | 21.7 (6.5, 61.5) | 23.4 (0, 51.6) | 25.7 (12.2, 60.2) | 0.712 |
| After LMA | 100 (100, 100) | 72.1 (40.0, 100) | 100 (69.0, 100) | 0.000 |
| Middle point | ||||
| Before LMA | 52.8 (29.1, 82.7) | 44.8 (18.5, 65.9) | 40.3 (19.6, 100) | 0.624 |
| After LMA | 100 (100, 100) | 100 (100, 100) | 100 (100, 100) | 0.318 |
| Low point | ||||
| Before LMA | 26.2 (0.0, 97.8) | 41.0 (11.5, 94.5) | 30.3 (0, 100) | 0.465 |
| After LMA | 67.8 (18.5, 100) | 56.3 (12.1, 100) | 54.7 (22.5, 100) | 0.993 |
P < 0.05 vs group 1;
P < 0.01 vs before laryngeal mask airway within group. Results are presented as median (interquartile range). LMA: Laryngeal mask airway.
Relationship between simulated needle path and internal jugular vein and common carotid artery, n (%)
| IJV | ||||
| Before LMA | 31 (96.9) | 38 (97.4) | 24 (82.8) | 0.059 |
| After LMA | 24 (75.0) | 31 (79.5) | 15 (51.7) | 0.036 |
| CCA | ||||
| Before LMA | 6 (18.8) | 8 (20.5) | 7 (24.1) | 0.871 |
| After LMA | 19 (59.4) | 17 (43.6) | 13 (44.8) | 0.361 |
| IJV and CCA | ||||
| Before LMA | 6 (18.8) | 7 (17.9) | 3 (10.3) | 0.613 |
| After LMA | 17 (53.1) | 16 (41.0) | 9 (31.0) | 0.215 |
P < 0.05 vs group 3;
P < 0.01 vs before laryngeal mask airway within group. IJV: Internal jugular vein; CCA: Common carotid artery; LMA: Laryngeal mask airway.
Cross-sectional area and blood flow velocity of the internal jugular vein
| Cross sectional area in cm2 | ||||
| Before LMA | 1.42 ± 0.48 | 1.66 ± 0.68 | 1.54 ± 0.66 | 0.350 |
| After LMA | 1.62 ± 0.56 | 1.82 ± 0.77 | 1.66 ± 0.65 | |
| Flow velocity in cm/s | ||||
| Before LMA | 31.25 ± 7.37 | 28.37 ± 8.49 | 31.82 ± 12.55 | 0.511 |
| After LMA | 24.07 ± 8.99 | 24.65 ± 8.55 | 26.45 ± 10.55 | |
Compared between groups;
Before LMA vs After LMA: P = 0.001;
Before LMA vs After LMA: P = 0.000. Results are presented as the mean ± SD. LMA: Laryngeal mask airway.