Literature DB >> 30968166

Outcomes of cerclage wiring to manage intra-operative femoral fracture occurring during cementless hemiarthroplasty in older patients with femoral neck fractures.

Aasis Unnanuntana1, Nakarin Saiyudthong2.   

Abstract

BACKGROUND: Cementless hemiarthroplasty is a widely used treatment for femoral neck fractures. Intra-operative femoral fracture occasionally occurs during the procedure, and the use of cerclage wire has been proposed to stabilize both the prosthesis and the bone. This study aimed to investigate the outcomes of cerclage wiring to manage intra-operative fractures occurring during cementless hemiarthroplasty in older patients with a femoral neck fracture.
METHODS: Medical records and radiographs of older patients with femoral neck fractures who underwent hemiarthroplasty during 2009 to 2015 were retrospectively reviewed. Patients who received cerclage wiring were matched with a demographically matched control group that did not. Patients were followed for at least 12 months. Functional outcomes and health-related quality of life were evaluated by determining the distance of distal stem migration, Barthel Index, EuroQol-visual analog scale (VAS), and pain-VAS.
RESULTS: Eighty-one patients were included, comprising 27 study group and 54 control group patients. A tapered wedge-shaped femoral prosthesis was implanted in all cases. No significant differences in distance of distal stem migration or rate of stem subsidence > 2 mm were observed between the case and control groups (subsidence rate 11.1 vs. 14.8%, respectively). There was also no significant difference in functional outcomes between groups.
CONCLUSION: Our results revealed a low mean distance of distal stem migration and a low subsidence rate. Functional outcomes and quality of life were similar between the two groups. Cerclage wiring technique is safe, and it should be routinely performed when intra-operative femoral fracture occurs during cementless hemiarthroplasty.

Entities:  

Keywords:  Cementless hemiarthroplasty; Cerclage wiring; Femoral neck fracture; Intra-operative femoral fracture; Older patients; Outcomes

Mesh:

Year:  2019        PMID: 30968166     DOI: 10.1007/s00264-019-04327-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  53 in total

1.  FUNCTIONAL EVALUATION: THE BARTHEL INDEX.

Authors:  F I MAHONEY; D W BARTHEL
Journal:  Md State Med J       Date:  1965-02

2.  Differences in subsidence rate between alternative designs of a commonly used uncemented femoral stem.

Authors:  Munnan Al-Najjim; Usman Khattak; Juluis Sim; Iain Chambers
Journal:  J Orthop       Date:  2016-07-05

3.  The visual analog scale in the immediate postoperative period: intrasubject variability and correlation with a numeric scale.

Authors:  L J DeLoach; M S Higgins; A B Caplan; J L Stiff
Journal:  Anesth Analg       Date:  1998-01       Impact factor: 5.108

4.  Validity and responsiveness of Barthel index for measuring functional recovery after hemiarthroplasty for femoral neck fracture.

Authors:  Aasis Unnanuntana; Atthakorn Jarusriwanna; Sarthak Nepal
Journal:  Arch Orthop Trauma Surg       Date:  2018-08-09       Impact factor: 3.067

Review 5.  Management of hip fractures in the elderly.

Authors:  Karl C Roberts; W Timothy Brox; David S Jevsevar; Kaitlyn Sevarino
Journal:  J Am Acad Orthop Surg       Date:  2015-02       Impact factor: 3.020

6.  Structural and cellular assessment of bone quality of proximal femur.

Authors:  L D Dorr; M C Faugere; A M Mackel; T A Gruen; B Bognar; H H Malluche
Journal:  Bone       Date:  1993 May-Jun       Impact factor: 4.398

7.  Biomechanical performance of different cable and wire cerclage configurations.

Authors:  Mark Lenz; Stephan Marcel Perren; Robert Geoff Richards; Thomas Mückley; Gunther Olaf Hofmann; Boyko Gueorguiev; Markus Windolf
Journal:  Int Orthop       Date:  2012-11-10       Impact factor: 3.075

8.  Periprosthetic fractures around a cementless hydroxyapatite-coated implant: a new fracture pattern is described.

Authors:  William N Capello; James A D'Antonio; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

9.  Comparison of functional outcome of bipolar hip arthroplasty and total hip replacement in displaced femoral neck fractures in elderly in a developing country: a 2-year prospective study.

Authors:  Jayesh Chandrakant Sonaje; Pradeep Kumar Meena; Ramesh Chandra Bansiwal; Sandesh Satish Bobade
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-13

Review 10.  Periprosthetic fractures evaluation and treatment.

Authors:  Bassam A Masri; R M Dominic Meek; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2004-03       Impact factor: 4.176

View more
  3 in total

1.  Application of Multimode Health Education Combined with Humanistic Care in Pain Management of Patients with Femoral Fracture and Its Influence on VAS Score.

Authors:  Ming Shi; Pengyu Zhang; Ling Xia; Zhiteng Wei; Fangjie Bi; Yujia Xu; Pan Wang
Journal:  J Healthc Eng       Date:  2021-12-13       Impact factor: 2.682

2.  Effects of Seamless Operating Room Nursing Combined with Multistyle Health Education on the Psychological State, Rehabilitation Quality, and Nursing Satisfaction in Patients with Internal Fixation of Femoral Fracture.

Authors:  Qingyan Liu; Juan Wang; Jie Han; Tongyang You; Lijuan Li
Journal:  J Healthc Eng       Date:  2022-04-05       Impact factor: 2.682

3.  A quantitative biomechanical study of positive buttress techniques for femoral neck fractures: a finite element analysis.

Authors:  Gang Wang; Bin Wang; Yong Tang; Hui-Lin Yang
Journal:  Chin Med J (Engl)       Date:  2019-11-05       Impact factor: 2.628

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.