Abstract
Tranexamic acid (TXA) is an antifibrinolytic which minimises bleeding and transfusions, with thrombotic risk. Our patient had known coronary artery disease with post-TXA acute ST-elevation myocardial infarction (STEMI) due to in-stent thrombosis. He had five drug-eluting stents (DES): two overlapping DES in mid-LAD (3 years ago), and two overlapping DES in distal right coronary artery and one DES in obtuse-marginal (1.5 years ago). After TXA, both overlapping stent locations thrombosed. Of nine reports of post-TXA acute MI, only one had complex stent anatomy (bifurcation stent to left circumflex/first obtuse-marginal) with other single stents, and only the complex stent thrombosed. Post-TXA MI was more often STEMI caused by arterial thrombosis, rather than non-STEMI caused by blood loss, hypotension or demand ischaemia. Overlapping and bifurcation stents thrombosed; single stents remained patent. In conclusion, overlapping stents, bifurcation stents, excessive stent length and previous in-stent restenosis/thrombosis may increase thrombotic risk. TXA should be administered cautiously with complex stent anatomy. © BMJ Publishing Group Limited 2019. No commercial re-use. See rights and permissions. Published by BMJ.Entities:
Keywords: cardiovascular medicine; ischaemic heart disease; orthopaedics; perioperative care; unwanted effects/adverse reactions
Mesh:
Substances:
Year: 2019 PMID: 30962209 PMCID: PMC6453394 DOI: 10.1136/bcr-2018-227957