| Literature DB >> 30942136 |
Kaifeng Gan1,2, Dingli Xu2, Yimu Lin3, Yandong Shen1,2, Ting Zhang1, Keqi Hu1, Ke Zhou1, Mingguang Bi1, Lingxiao Pan1, Wei Wu4, Yunpeng Liu5.
Abstract
Background and purpose - Artificial intelligence has rapidly become a powerful method in image analysis with the use of convolutional neural networks (CNNs). We assessed the ability of a CNN, with a fast object detection algorithm previously identifying the regions of interest, to detect distal radius fractures (DRFs) on anterior-posterior (AP) wrist radiographs. Patients and methods - 2,340 AP wrist radiographs from 2,340 patients were enrolled in this study. We trained the CNN to analyze wrist radiographs in the dataset. Feasibility of the object detection algorithm was evaluated by intersection of the union (IOU). The diagnostic performance of the network was measured by area under the receiver operating characteristics curve (AUC), accuracy, sensitivity, specificity, and Youden Index; the results were compared with those of medical professional groups. Results - The object detection model achieved a high average IOU, and none of the IOUs had a value less than 0.5. The AUC of the CNN for this test was 0.96. The network had better performance in distinguishing images with DRFs from normal images compared with a group of radiologists in terms of the accuracy, sensitivity, specificity, and Youden Index. The network presented a similar diagnostic performance to that of the orthopedists in terms of these variables. Interpretation - The network exhibited a diagnostic ability similar to that of the orthopedists and a performance superior to that of the radiologists in distinguishing AP wrist radiographs with DRFs from normal images under limited conditions. Further studies are required to determine the feasibility of applying our method as an auxiliary in clinical practice under extended conditions.Entities:
Mesh:
Year: 2019 PMID: 30942136 PMCID: PMC6718190 DOI: 10.1080/17453674.2019.1600125
Source DB: PubMed Journal: Acta Orthop ISSN: 1745-3674 Impact factor: 3.717
Figure 1.A wrist radiograph was manually annotated with a red rectangle as the ground truth bound and automatically annotated with a blue rectangle as the candidate bound. The red rectangle and blue rectangle represent edges of the region of interest (ROI) detected by the orthopedists and edges of the ROI detected by Faster R-CNN, respectively.
Figure 2.The formula with which the Intersection of the Union (IOU) was calculated.
Figure 3.A typical example of the augmentation on 1 image from the annotated training dataset during the training course of Inception-v4.
Figure 4.Flow diagram of the training and test courses of Faster R-CNN (shown in a green) and Inception-v4 (shown in a red).
Demographic data of the whole dataset with 2,340 patients enrolled in this study
| Factor | Patients with DRFs (n = 1,491) | Patients without DRFs (n = 849) | Total (n = 2,340) | Comparison (p-value) |
|---|---|---|---|---|
| Age, mean (CI) | 48 (48–49) | 48 (47–49) | 48 (48–49) | 0.4 |
| Sex, n (%) | ||||
| Male | 833 (56) | 533 (63) | 1,366 (58) | < 0.01 |
| Female | 658 (44) | 316 (37) | 974 (42) |
DRFs = distal radius fractures.
CI = 95% confidence interval.
P-values were derived from 1-way analysis of variance for age and chi-square tests for sex.
Figure 5.The receiver operating characteristic (ROC) curve for the test output of the Inception-v4 model. The dots on the plot represent the sensitivity and 1-specificity of the human groups (the blue dot represents the orthopedists’ group; the red dot represents the radiologists’ group). The sensitivity/1-specificity dot of the radiologists’ group lies below the ROC curve of the Inception-v4 model, and the sensitivity/1-specificity dot of the orthopedists’ group lies above the ROC curve of the Inception-v4 model.
Performance differences in the outcomes between Inception-v4 and each human group
| Factor | Differences between orthopedists Difference | Inception-v4 and radiologists Difference |
|---|---|---|
| Accuracy (%) | –1 (–5 to 3) | 9 (3–15) |
| Sensitivity (%) | –3 (–9 to 4) | 9 (1–16) |
| Specificity (%) | 1 (–5 to 7) | 9 (3–16) |
| Youden Index | –0.01 (–0.09 to 0.06) | 0.18 (8–27) |
CI = 95% confidence interval.
Difference = (mean of the outcome of Inception-v4) – (mean of the outcome of orthopedists).
Difference = (mean of the outcome of Inception-v4) – (mean of the outcome of radiologists).
Diagnostic performance of the model and human groups
| Factor | Inception-v4 | Orthopedists | Radiologists | F-value | p-value |
|---|---|---|---|---|---|
| Accuracy (%) [CI] | 279/300 (93) [90–96] | 281/300 (94) [91–96] | 252/300 (84) [80–88] a | 10.19 | < 0.001 |
| Sensitivity (%) [CI] | 135/150 (90) [85–95] | 139/150 (93) [89–97] | 122/150 (81) [75–87] | 5.07 | 0.007 |
| Specificity (%) [CI] | 144/150 (96) [93–99] | 142/150 (95) [91–98] | 130/150 (87) [81–92] | 4.82 | 0.009 |
| Youden Index (CI) | 0.86 (0.80–0.91) | 0.87 (0.82–0.93) | 0.68 (0.61–0.75) | 11.62 | < 0.001 |
CI = 95% confidence interval.
Statistically significant in a comparison of Inception-v4 and each human group (results from Dunnett’s test).
Figure 6.The same wrist with a DRF in the anterior–posterior view radiograph (a) and in the lateral view radiograph (b). The hidden DRF in the anterior–posterior view was apparent in the lateral view (the fracture is shown by the red arrow).