Literature DB >> 30939631

Rapid and Sensitive Detection of Salmonella in Chickens Using Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick.

Zhi Liu1, Qiu Zhang2, Ning-Ning Yang1, Ming-Guo Xu1, Jin-Feng Xu3, Ming-Long Jing1, Wen-Xing Wu1, Ya-Dong Lu1, Feng Shi3,4, Chuang-Fu Chen1,5.   

Abstract

Salmonellosis is a highly contagious bacterial disease that threatens both human and poultry health. Tests that can detect Salmonella in the field are urgently required to facilitate disease control and for epidemiological investigations. Here, we combined loop-mediated isothermal amplification (LAMP) with a chromatographic lateral flow dipstick (LFD) to rapidly and accurately detect Salmonella. LAMP primers were designed to target the Salmonella invA gene. LAMP conditions were optimized by adjusting the ratio of inner to outer primers, MgSO4 concentration, dNTP mix concentration, amplification temperature, and amplification time. We evaluated the specificity of our novel LAMP-LFD method using six Salmonella species and six related non-Salmonella strains. All six of the Salmonella strains, but none of the non-Salmonella strains, were amplified. LAMP-LFD was sensitive enough to detect concentrations of Salmonella enterica subsp. enterica serovar Pullorum genomic DNA as low as 89 fg/µl, which is 1,000 times more sensitive than conventional PCR. When artificially contaminated feed samples were analyzed, LAMP-LFD was also more sensitive than PCR. Finally, LAMP-LFD gave no false positives across 350 chicken anal swabs. Therefore, our novel LAMP-LFD assay was highly sensitive, specific, convenient, and fast, making it a valuable tool for the early diagnosis and monitoring of Salmonella infection in chickens.

Entities:  

Keywords:  Salmonella; detection; invA gene; lateral flow dipstick; loop-mediated isothermal amplification

Mesh:

Substances:

Year:  2019        PMID: 30939631     DOI: 10.4014/jmb.1712.12010

Source DB:  PubMed          Journal:  J Microbiol Biotechnol        ISSN: 1017-7825            Impact factor:   2.351


  2 in total

1.  Detection of harmful foodborne pathogens in food samples at the points of sale by MALDT-TOF MS in Egypt.

Authors:  Dalia F Khater; Radwa A Lela; Mohamed El-Diasty; Shawky A Moustafa; Gamal Wareth
Journal:  BMC Res Notes       Date:  2021-03-23

2.  Comparative analysis of loop-mediated isothermal amplification combined with microfluidic chip technology and q-PCR in the detection of clinical infectious pathogens.

Authors:  Enqi Zhang; Hongling Ou; Lianling Jia; Wang Zhang; Yemei Wang; Xinru Wang
Journal:  J Clin Lab Anal       Date:  2022-06-26       Impact factor: 3.124

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.