Second-generation cryoballoon ablation for recurrent atrial fibrillation after an index procedure with radiofrequency versus cryo: Different pulmonary vein reconnection patterns but similar long-term outcome-Results of a multicenter analysis.

Andrzej Glowniak1, Adam Tarkowski1, Piotr Fic2, Katarzyna Wojewoda1, Jaroslaw Wojcik1,3, Andrzej Wysokinski1.   

Abstract

INTRODUCTION: Repeated procedures are often needed for long-term success of atrial fibrillation ablation. There are scarce data regarding cryoballoon use for such procedure. METHODS AND
RESULTS: We analyzed acute effect and long-term follow-up of second-generation cryoballoon ablation, performed as a repeat procedure after an index radiofrequency vs cryoballoon ablation. Sixty-one patients from three centers were included. In 36 cases radiofrequency (RF-I) and in 25 cryoballoon ablation (CB-I) was the index procedure. During redo procedure, pulmonary vein reconnection was less frequent in CB-I vs RF-I (51.5% vs 66.9%; P = 0.017). After cryoballoon, left inferior (P =  0.027) and right superior (P = 0.06) pulmonary veins were less likely to exhibit reconnection. Moreover, patients after initial RF ablation frequently presented multiple-vein reconnection (P = 0.018), while patients after cryoablation more often had only one vein reconnected (P = 0.008). During reablation procedures, all 149 reconnected veins in both groups were isolated, with no differences in procedural parameters, except for procedure time, shorter in CB-I group (65.5 vs 71.1 minutes; P = 0.04). Transient phrenic nerve palsy was the only complication in both groups (5.6% and 8.0%; ns). After mean follow-up of 15 ± 9 months, 70.3% of patients were free from atrial fibrillation (AF), with no differences between the groups (P = 0.71). In multivariate Cox-regression analysis, the persistent form of arrhythmia (P = 0.009) and relapse in the blanking period (P = 0.0004) were the only independent predictors of AF recurrence.
CONCLUSIONS: The use of second-generation cryoballoon is associated with less frequent pulmonary vein reconnection compared with RF ablation. Cryoballoon is safe and effective for repeated AF ablation, regardless of the technique used for the initial procedure.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  atrial fibrillation; cryoballoon ablation; pulmonary vein reconnection; redo ablation

Year:  2019        PMID: 30938917     DOI: 10.1111/jce.13938

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  11 in total

1.  Is the time of atrial fibrillation recurrence after cryoballoon ablation of paroxysmal atrial fibrillation influenced by the pattern of PV reconnections?

Authors:  Marcus Wieczorek; Kiarash Sassani; Reinhard Hoeltgen
Journal:  J Interv Card Electrophysiol       Date:  2020-07-03       Impact factor: 1.900

2.  Paroxysmal atrial fibrillation recurrence after redo procedure-ablation modality impact.

Authors:  Ivan Zeljkovic; Sven Knecht; Florian Spies; Tobias Reichlin; Stefan Osswald; Michael Kühne; Christian Sticherling
Journal:  J Interv Card Electrophysiol       Date:  2020-01-07       Impact factor: 1.900

3.  A novel alternating second-generation cryoballoon or contact-force guided radiofrequency catheter ablation strategy for redo-ablation in patients with recurrent atrial fibrillation: a single-center experience.

Authors:  Qing-Hui Tang; Xiao-Gang Guo; Jian Ma
Journal:  J Interv Card Electrophysiol       Date:  2022-08-10       Impact factor: 1.759

4.  Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial.

Authors:  Samuel K Sørensen; Arne Johannessen; René Worck; Morten L Hansen; Jim Hansen
Journal:  Circ Arrhythm Electrophysiol       Date:  2021-04-09

5.  Comparison of pulmonary vein reconnection patterns after multielectrode phased radiofrequency- and cryoballoon ablation of atrial fibrillation.

Authors:  Marcus Wieczorek; Kiarash Sassani; Reinhard Hoeltgen
Journal:  BMC Cardiovasc Disord       Date:  2020-04-23       Impact factor: 2.298

6.  Is the Time of Atrial Fibrillation Recurrence After Duty-Cycled Radiofrequency Ablation Affected by the Pattern of Pulmonary Vein Reconnections?

Authors:  Marcus Wieczorek; Kiarash Sassani; Reinhard Hoeltgen
Journal:  Cardiol Res       Date:  2020-05-03

7.  Outcomes of atrial fibrillation ablation program based on single-shot techniques.

Authors:  Marek Jastrzębski; Grzegorz Kiełbasa; Kamil Fijorek; Adam Bednarski; Aleksander Kusiak; Tomasz Sondej; Agnieszka Bednarek; Pawel Lis; Agnieszka Olszanecka; Marek Rajzer
Journal:  Postepy Kardiol Interwencyjnej       Date:  2020-12-29       Impact factor: 1.426

8.  Impact of pulmonary vein ovality index on cooling kinetics and acute success of atrial fibrillation ablation with the third-generation cryoballoon catheter.

Authors:  Milena Stachyra; Marcin Szczasny; Adam Tarkowski; Magdalena Mianowana; Katarzyna Wojewoda; Katarzyna Wysokinska; Piotr Blaszczak; Andrzej Głowniak
Journal:  Postepy Kardiol Interwencyjnej       Date:  2021-11-17       Impact factor: 1.426

9.  Atrial Fibrillation Ablation with Multipolar Phased-Radiofrequency Catheter: The Learning Curve Effect for Procedural Parameters, but not for the Long-Term Outcome.

Authors:  Andrzej Glowniak; Adam Tarkowski; Katarzyna Wojewoda; Katarzyna Wysokinska; Mariusz Kozak; Piotr Wacinski; Andrzej Wysokinski
Journal:  J Clin Med       Date:  2019-10-02       Impact factor: 4.241

10.  Remote proctoring for cryoballoon ablation of atrial fibrillation: A challenge or an opportunity in the COVID-19 era?

Authors:  Andrzej Glowniak; Myroslav Petkanych; Katarzyna Wojewoda; Vladimir Komiaty; Marcin Sudol; Oksana Dyomenko; Kamil Torres; Andrzej Wysokinski; Antonio Sorgente; Gian-Battista Chierchia; Carlo de Asmundis
Journal:  Cardiol J       Date:  2021-09-15       Impact factor: 2.737

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.