Literature DB >> 30937525

Intraoperative measurement of cup inclination using fluoroscopy requires a correction factor.

Kilian Rueckl1, Diego J Alcaide1, Bernhard Springer1, Stefan Rueckl1, Maximilian F Kasparek2, Friedrich Boettner3.   

Abstract

INTRODUCTION: Malpositioning of the cup in total hip arthroplasty (THA) is associated with dislocation, early polyethylene wear, and impingement. The direct anterior approach (DAA) THA allows for intraoperative fluoroscopy imaging (IF). The current study investigates the following research hypotheses: (1) intraoperative measurements of radiographic cup inclination (RI) are reliable and reproducible. (2) A correction factor can compensate for the complex parallax effects when using IF.
METHODS: In 2016, 100 consecutive hips underwent primary THA utilizing DAA and IF for cup placement. RI was measured on intraoperative fluoroscopy images and postoperative AP pelvis radiographs.
RESULTS: Determination of RI on IF images is reliable and reproducible (ICC 0.851-0.950). RI measurement on IF images had a good correlation with the corresponding postoperative RI on AP pelvis radiographs (r = 0.538, p < 0.001). However, intraoperative RI measurements are on average 4.9° lower compared to postoperative measurements (SD 2.5°).
CONCLUSION: Intraoperative fluoroscopy is a reliable tool to measure RI during DAA THA. The surgeon needs to apply a 5°. correction factor to the intraoperative measurements to adjust for parallax.

Entities:  

Keywords:  Cup positioning; Inclination; Intraoperative fluoroscopy; THA

Year:  2019        PMID: 30937525     DOI: 10.1007/s00402-019-03168-w

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  4 in total

Review 1.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

2.  Accuracy and Reliability of Software Navigation for Acetabular Component Placement in THA: An In Vitro Validation Study.

Authors:  Alex W Brady; Jakub Tatka; Lorenzo Fagotti; Bryson R Kemler; Bradley W Fossum
Journal:  Medicina (Kaunas)       Date:  2022-05-14       Impact factor: 2.948

3.  Anterior hip replacement: lower dislocation rates despite less restrictions?

Authors:  Anna Jungwirth-Weinberger; Tom Schmidt-Braekling; Kilian Rueckl; Bernhard Springer; Friedrich Boettner
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-09       Impact factor: 2.928

4.  Component placement accuracy of two digital intraoperative fluoroscopy supplementation systems in direct anterior total hip arthroplasty.

Authors:  Tyler Thorne; Scott Nishioka; Samantha Andrews; Kristin Mathews; Cass Nakasone
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-23       Impact factor: 3.067

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.