Literature DB >> 30929489

Is a modular dual mobility acetabulum a viable option for the young, active total hip arthroplasty patient?

D Nam1, R Salih2, C R Nahhas1, R L Barrack2, R M Nunley2.   

Abstract

AIMS: Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell ( vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown improved stability in patients deemed 'high-risk' for dislocation undergoing total hip arthroplasty (THA), their performance in young, active patients has not been reported. This study's purpose was to assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular DM acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design. PATIENTS AND METHODS: This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m2 and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. A total of 43 patients (30 male, 13 female; mean age 52.6 years (sd 6.5)) were enrolled. All patients had a minimum of two years' clinical follow-up. Patient-reported outcome measures, whole blood metal ion levels (ug/l), and periprosthetic femoral BMD were measured at baseline, as well as at one and two years postoperatively. Power analysis indicated 40 patients necessary to demonstrate a five-fold increase in cobalt levels from baseline (alpha = 0.05, beta = 0.80). A mixed model with repeated measures was used for statistical analysis.
RESULTS: Mean Harris Hip Scores improved from 54.1 (sd 20.5) to 91.2 (sd 10.8) at two years postoperatively (p < 0.001). All patients had radiologically well-fixed components, no patients experienced any instability, and no patients required any further intervention. Mean cobalt levels increased from 0.065 ug/l (sd 0.03) preoperatively to 0.30 ug/l (sd 0.51) at one year postoperatively (p = 0.01) but decreased at two years postoperatively to 0.16 ug/l (sd 0.23; p = 0.2). Four patients (9.3%) had a cobalt level outside the reference range (0.03 ug/l to 0.29 ug/l) at two years postoperatively, with values from 0.32 ug/l to 0.94 ug/l. The mean femoral BMD ratio was maintained in Gruen zones 2 to 7 at both one and two years postoperatively using this stem design. At two years postoperatively, mean BMD in the medial calcar was 101.5% of the baseline value.
CONCLUSION: Use of a modular DM prosthesis and cementless, tapered femoral stem has shown encouraging results in young, active patients undergoing primary THA. Elevation in mean cobalt levels and the presence of four patients outside the reference range at two years postoperatively demonstrates the necessity of continued surveillance in this cohort. Cite this article: Bone Joint J 2019;101-B:365-371.

Entities:  

Keywords:  Bone density; Clinical outcomes; Dual mobility; Metal ions; Total hip arthroplasty

Mesh:

Year:  2019        PMID: 30929489     DOI: 10.1302/0301-620X.101B4.BJJ-2018-0834.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  11 in total

Review 1.  Serum metal ion levels in modular dual mobility acetabular components: A systematic review.

Authors:  Ioannis Gkiatas; Abhinav K Sharma; Alexander Greenberg; Stephen T Duncan; Brian P Chalmers; Peter K Sculco
Journal:  J Orthop       Date:  2020-08-25

Review 2.  A meta-analysis assessing time for return to sport following hip resurfacing.

Authors:  A Magan; W Wignadasan; B Kayani; G Radhakrishnan; F Ronca; F S Haddad
Journal:  Arch Orthop Trauma Surg       Date:  2022-08-30       Impact factor: 2.928

3.  In Revision THA, Is the Re-revision Risk for Dislocation and Aseptic Causes Greater in Dual-mobility Constructs or Large Femoral Head Bearings? A Study from the Australian Orthopaedic Association National Joint Replacement Registry.

Authors:  Wayne Hoskins; Sophia Rainbird; Chelsea Dyer; Stephen E Graves; Roger Bingham
Journal:  Clin Orthop Relat Res       Date:  2022-01-03       Impact factor: 4.755

4.  Serum Metal Ions in Contemporary Monoblock and Modular Dual Mobility Articulations.

Authors:  Alexander Greenberg; Allina Nocon; Ivan De Martino; David J Mayman; Thomas P Sculco; Peter K Sculco
Journal:  Arthroplast Today       Date:  2021-10-29

5.  Prevention of early complications following total hip replacement.

Authors:  Andreas Fontalis; Daniel J Berry; Andrew Shimmin; Pablo A Slullitel; Martin A Buttaro; Cao Li; Henrik Malchau; Fares S Haddad
Journal:  SICOT J       Date:  2021-11-30

6.  Hip stability parameters with dual mobility, modular dual mobility and fixed bearing in total hip arthroplasty: an analytical evaluation.

Authors:  Domenico Tigani; Lorenzo Banci; Riccardo Valtorta; Luca Amendola
Journal:  BMC Musculoskelet Disord       Date:  2022-04-20       Impact factor: 2.562

Review 7.  Metal ion levels with use of modular dual mobility constructs: Can the evidence guide us on clinical use?

Authors:  Atul F Kamath; P Maxwell Courtney; Gwo-Chin Lee
Journal:  J Orthop       Date:  2021-02-20

Review 8.  Adverse reaction to metal debris due to fretting corrosion between the acetabular components of modular dual-mobility constructs in total hip replacement: a systematic review and meta-analysis.

Authors:  Jonathan M R French; Paul Bramley; Sean Scattergood; Nemandra A Sandiford
Journal:  EFORT Open Rev       Date:  2021-05-04

9.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

10.  Response to letter to the editor on "Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal ion levels".

Authors:  Maarten Cornelis Koper; Koen Bos
Journal:  Arthroplast Today       Date:  2020-02-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.