Pre-Dilatation Versus No Pre-Dilatation for Implantation of a Self-Expanding Valve in All Comers Undergoing TAVR: The DIRECT Trial.

Konstantinos Toutouzas1, Georgios Benetos2, Vasilis Voudris3, Maria Drakopoulou2, Konstantinos Stathogiannis2, George Latsios2, Andreas Synetos2, Alexios Antonopoulos2, Elias Kosmas3, Ioannis Iakovou3, Georgios Katsimagklis4, Antonios Mastrokostopoulos4, Sotiris Moraitis4, Vicki Zeniou5, Haim Danenberg5, Manolis Vavuranakis2, Dimitris Tousoulis2.   

Abstract

OBJECTIVES: The aim of this study was to compare the implantation of a self-expanding valve with or without balloon aortic valvuloplasty (BAV) in an open-label, noninferiority, randomized trial.
BACKGROUND: There are no randomized studies comparing the implantation of a self-expanding valve with (pre-BAV) or without BAV.
METHODS: Consecutive patients with severe aortic stenosis were randomly assigned to undergo transcatheter aortic valve replacement with the use of self-expanding prostheses with (pre-BAV) or without (no-BAV) pre-dilatation. The primary endpoint was device success according to the Valve Academic Research Consortium 2 criteria. Secondary endpoints included periprocedural mortality and stroke, new permanent pacemaker implantation, vascular complications, and 1-year mortality. The trial was scheduled to show noninferiority (Δ = 15%) of the direct versus the pre-BAV approach.
RESULTS: A total of 171 patients were randomized at 4 centers. Of these, 86 underwent transcatheter aortic valve replacement with pre-dilatation and 85 without. Device success was noninferior in the no-BAV group compared with the pre-BAV group (65 of 85 [76.5%] for no-BAV vs. 64 of 86 [74.4%] for pre-BAV; mean difference 2.1%; 90% confidence interval: -8.9% to 13%). In the no-BAV group, 25 patients (29.4%) underwent post-balloon dilatation, and in the pre-BAV group, 13 patients (15.1%) underwent post-balloon dilatation (p = 0.03). Regarding major vascular complications and permanent pacemaker implantation, there was no difference between the 2 groups (log-rank p = 0.49, log-rank p = 0.54). In 1-month completed follow-up for all patients, there was 1 periprocedural stroke (0.5%), without any deaths.
CONCLUSIONS: Direct, without balloon pre-dilatation, transcatheter aortic valve replacement with a self-expanding prosthesis system is noninferior to the pre-dilatation procedure. Lower post-dilatation rates were encountered in the group with pre-dilatation. (The Predilatation in Transcatheter Aortic Valve Implantation Trial [DIRECT]; NCT02448927).
Copyright © 2019 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  TAVR; device success; pre-dilatation; self-expanding valve

Mesh:

Year:  2019        PMID: 30928442     DOI: 10.1016/j.jcin.2019.02.005

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  4 in total

Review 1.  Simplified TAVR Procedure: How Far Is It Possible to Go?

Authors:  Florence Leclercq; Pierre Alain Meunier; Thomas Gandet; Jean-Christophe Macia; Delphine Delseny; Philippe Gaudard; Marc Mourad; Laurent Schmutz; Pierre Robert; François Roubille; Guillaume Cayla; Mariama Akodad
Journal:  J Clin Med       Date:  2022-05-16       Impact factor: 4.964

2.  Overcoming the transcatheter aortic valve replacement Achilles heel: conduction abnormalities-a systematic review.

Authors:  Alberto Alperi; Guillem Muntané-Carol; Afonso B Freitas-Ferraz; Lucia Junquera; David Del Val; Laurent Faroux; François Philippon; Josep Rodés-Cabau
Journal:  Ann Cardiothorac Surg       Date:  2020-11

3.  The Technological Basis of a Balloon-Expandable TAVR System: Non-occlusive Deployment, Anchorage in the Absence of Calcification and Polymer Leaflets.

Authors:  Harish Appa; Kenneth Park; Deon Bezuidenhout; Braden van Breda; Bruce de Jongh; Jandré de Villiers; Reno Chacko; Jacques Scherman; Chima Ofoegbu; Justiaan Swanevelder; Michael Cousins; Paul Human; Robin Smith; Ferdinand Vogt; Bruno K Podesser; Christoph Schmitz; Lenard Conradi; Hendrik Treede; Holger Schröfel; Theodor Fischlein; Martin Grabenwöger; Xinjin Luo; Heather Coombes; Simon Matskeplishvili; David F Williams; Peter Zilla
Journal:  Front Cardiovasc Med       Date:  2022-03-03

4.  Temporal Trends of Transcatheter Aortic Valve Implantation over 12 Years: A High-Volume Single-Center Experience.

Authors:  Shir Frydman; David Zahler; Ilan Merdler; Ophir Freund; Yacov Shacham; Shmuel Banai; Ariel Finkelstein; Arie Steinvil
Journal:  J Clin Med       Date:  2022-08-24       Impact factor: 4.964

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.