Literature DB >> 30927057

Crossover comparison between CPAP and mandibular advancement device with adherence monitor about the effects on endothelial function, blood pressure and symptoms in patients with obstructive sleep apnea.

Umpei Yamamoto1,2, Mari Nishizaka3,4, Hiroko Tsuda1,5, Hiroyuki Tsutsui4, Shin-Ichi Ando6,7.   

Abstract

Mandibular advancement device (MAD) is an alternative therapeutic option for CPAP to treat obstructive sleep apnea (OSA). While MAD showed the better adherence, patients with over moderate OSA have been treated more frequently with CPAP despite increasing positive evidence on the cardiovascular outcome with MAD, even in severe patients. Thus, more information is needed regarding the cardiovascular and symptomatic outcome of MAD treatment objectively compared to CPAP. Forty-five supine-dependent OSA patients (apnea-hypopnea index 20-40/h) were randomized to either CPAP or MAD and treated for 8 weeks and switched to another for 8 weeks. The primary endpoint was improvement in the endothelial function, indexed by the flow-mediated dilatation (FMD), and the secondary endpoint was the sleep-time blood pressure (BP). The duration of MAD use was evaluated objectively by an implanted adherence monitor. Treatment efficacy was also evaluated by home sleep monitor and a questionnaire about the symptoms. The adherence was not significantly different (CPAP vs. MAD: 274.5 ± 108.9 min/night vs. 314.8 ± 127.0 min/night, p = 0.095). FMD and sleep-time mean BP were not markedly changed from the baseline with either approach (CPAP vs. MAD: FMD, + 0.47% ± 3.1% vs. + 0.85% ± 2.6%, p = 0.64; BP, - 1.5 ± 5.7 mmHg vs. - 1.2 ± 7.5 mmHg, p = 0.48), although sleepiness, nocturia, and sleep-related parameters were similarly improved and more patients preferred MAD. As MAD and CPAP showed similar effects on cardiovascular outcome and symptomatic relief even with a comparable length of usage, we might expect MAD as an alternative treatment option for CPAP in this range of OSA group.

Entities:  

Keywords:  CPAP; Endothelial function; Mandibular advancement device; Obstructive sleep apnea

Mesh:

Year:  2019        PMID: 30927057     DOI: 10.1007/s00380-019-01392-3

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  46 in total

1.  Nocturia in sleep disordered breathing.

Authors: 
Journal:  Sleep Med       Date:  2000-10-01       Impact factor: 3.492

2.  Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery: a report of the International Brachial Artery Reactivity Task Force.

Authors:  Mary C Corretti; Todd J Anderson; Emelia J Benjamin; David Celermajer; Francois Charbonneau; Mark A Creager; John Deanfield; Helmut Drexler; Marie Gerhard-Herman; David Herrington; Patrick Vallance; Joseph Vita; Robert Vogel
Journal:  J Am Coll Cardiol       Date:  2002-01-16       Impact factor: 24.094

3.  Improved analysis of brachial artery ultrasound using a novel edge-detection software system.

Authors:  R J Woodman; D A Playford; G F Watts; C Cheetham; C Reed; R R Taylor; I B Puddey; L J Beilin; V Burke; T A Mori; D Green
Journal:  J Appl Physiol (1985)       Date:  2001-08

4.  Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study.

Authors:  Jose M Marin; Santiago J Carrizo; Eugenio Vicente; Alvar G N Agusti
Journal:  Lancet       Date:  2005 Mar 19-25       Impact factor: 79.321

5.  The effects of 1-year treatment with a herbst mandibular advancement splint on obstructive sleep apnea, oxidative stress, and endothelial function.

Authors:  Sarah Itzhaki; Hezi Dorchin; Glenn Clark; Lena Lavie; Peretz Lavie; Giora Pillar
Journal:  Chest       Date:  2007-03       Impact factor: 9.410

6.  Randomized crossover trial of two treatments for sleep apnea/hypopnea syndrome: continuous positive airway pressure and mandibular repositioning splint.

Authors:  Heather M Engleman; James P McDonald; David Graham; Glenn E Lello; Ruth N Kingshott; Emma L Coleman; Thomas W Mackay; Neil J Douglas
Journal:  Am J Respir Crit Care Med       Date:  2002-09-15       Impact factor: 21.405

7.  Endothelial function in obstructive sleep apnea and response to treatment.

Authors:  Mary S M Ip; Hung-Fat Tse; Bing Lam; Kenneth W T Tsang; Wah-Kit Lam
Journal:  Am J Respir Crit Care Med       Date:  2003-10-09       Impact factor: 21.405

8.  Mandibular advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success.

Authors:  Marie Marklund; Hans Stenlund; Karl A Franklin
Journal:  Chest       Date:  2004-04       Impact factor: 9.410

9.  Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea.

Authors:  Maree Barnes; R Douglas McEvoy; Siobhan Banks; Natalie Tarquinio; Christopher G Murray; Norman Vowles; Robert J Pierce
Journal:  Am J Respir Crit Care Med       Date:  2004-06-16       Impact factor: 21.405

Review 10.  Obstructive sleep apnea: implications for cardiac and vascular disease.

Authors:  Abu S M Shamsuzzaman; Bernard J Gersh; Virend K Somers
Journal:  JAMA       Date:  2003-10-08       Impact factor: 56.272

View more
  5 in total

Review 1.  Obstructive sleep apnea therapy for cardiovascular risk reduction-Time for a rethink?

Authors:  Hasthi U Dissanayake; Juliana T Colpani; Kate Sutherland; Weiqiang Loke; Anna Mohammadieh; Yi-Hui Ou; Philip de Chazal; Peter A Cistulli; Chi-Hang Lee
Journal:  Clin Cardiol       Date:  2021-11-17       Impact factor: 2.882

Review 2.  Hypoxic Regulation of the Large-Conductance, Calcium and Voltage-Activated Potassium Channel, BK.

Authors:  Sara V Ochoa; Liliana Otero; Andres Felipe Aristizabal-Pachon; Fernando Hinostroza; Ingrid Carvacho; Yolima P Torres
Journal:  Front Physiol       Date:  2021-12-22       Impact factor: 4.566

Review 3.  Treatment options in obstructive sleep apnea.

Authors:  Francesco Gambino; Marta Maria Zammuto; Alessandro Virzì; Giosafat Conti; Maria Rosaria Bonsignore
Journal:  Intern Emerg Med       Date:  2022-04-23       Impact factor: 5.472

Review 4.  The multisystemic effects of oral appliance therapy for obstructive sleep apnea: A narrative review.

Authors:  Hee Young Kim; Jung Hwan Jo; Jin Woo Chung; Ji Woon Park
Journal:  Medicine (Baltimore)       Date:  2022-07-22       Impact factor: 1.817

5.  The treatment of mild OSA with CPAP or mandibular advancement device and the effect on blood pressure and endothelial function after one year of treatment.

Authors:  Thais Moura Guimarães; Dalva Poyares; Luciana Oliveira E Silva; Gabriela Luz; Glaury Coelho; Cibele Dal Fabbro; Sergio Tufik; Lia Bittencourt
Journal:  J Clin Sleep Med       Date:  2021-02-01       Impact factor: 4.062

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.