Literature DB >> 30926043

MESIA: Magnetic force-assisted electrochemical sandwich immunoassays for quantification of prostate-specific antigen in human serum.

Hyundoo Hwang1, Eunjong Choi2, Seungmok Han2, Yunsung Lee2, Taehwa Choi2, Mikyoung Kim2, Haegong Shin2, Jaesik Kim2, Jaekyu Choi2.   

Abstract

We propose a new immunoassay technique, called magnetic-force assisted electrochemical sandwich immunoassay (MESIA), where serum biomarkers can be determined by magnetic actuation and electrochemical detection of gold-coated iron oxide nanoparticles as probes for immunocomplex formation. In MESIA, neither washing buffer nor fluidic parts are necessary, because the formation of immunocomplexes and the removal of unbound probes are controlled by magnetic forces. Electrochemical pretreatment and measurement of the gold-coated magnetic probes allows highly sensitive, precise, and robust system for quantification of target analytes. Using MESIA, the concentration of prostate-specific antigen (PSA) in 10 μl of human serum is determined within 5 min. The limit of detection is 0.085 ng/mL, and the average coefficient of variance is 8.85% for five different PSA concentrations ranging from 0 to 25 ng/mL. This method shows good precision and reproducibility (<10%) and high correlation with cobas e 801 (r = 0.997) for clinical patient samples. We believe this technique to be useful in the development of a point-of-care testing platform for diagnosis and prognosis of various diseases, such as cancer, based on quantification of biomarkers in a drop of blood.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemistry; Gold-coated magnetic nanoparticles; Magnetic force; Prostate-specific antigen; Sandwich immunoassay

Mesh:

Substances:

Year:  2019        PMID: 30926043     DOI: 10.1016/j.aca.2019.02.018

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

Review 1.  Lab-on-a-Chip Devices for Point-of-Care Medical Diagnostics.

Authors:  Sofia Arshavsky-Graham; Ester Segal
Journal:  Adv Biochem Eng Biotechnol       Date:  2022       Impact factor: 2.768

2.  Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen.

Authors:  Boo Young Hwang; Eunsoo Kim; Seung-Ha Kim; Hyundoo Hwang
Journal:  Front Bioeng Biotechnol       Date:  2022-01-03

3.  Evaluation of the clinical performance of a magnetic force-assisted electrochemical immunoassay for the detection of SARS-CoV-2 antigens.

Authors:  Sung Jin Jo; Sang-Hyun Shin; Jungrok Kim; Seungok Lee; Jehoon Lee
Journal:  PLoS One       Date:  2021-10-07       Impact factor: 3.752

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.