| Literature DB >> 30922281 |
Alexander Franz1, Modesto Raabe2, Bledar Lilaj1, Rinet Dauti1, Andreas Moritz1, Dieter Müßig3, Barbara Cvikl4,5.
Abstract
BACKGROUND: In view of the increasing demand of adult orthodontics for esthetic purposes, adult treatment with brackets has become an important issue. One essential factor for the quality of such treatment is bracket bonding on ceramics. For testing the adhesive bond between the bracket and the ceramic surface it is important to consider the static or cyclic loading that goes along with it.Entities:
Mesh:
Substances:
Year: 2019 PMID: 30922281 PMCID: PMC6437858 DOI: 10.1186/s12903-019-0740-6
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Detailed compositions of Monobond S and Monobond Etch & Prime
| Monobond S: | Monobond Etch & Prime: |
|---|---|
| Silane methacrylate | Silane methacrylate |
| Alcohol and water | Alcohol and water |
| Ammonium polyfluoride |
Fig. 1Flowchart of the experimental procedures
Materials and manufacturers
| inCoris TZI zirconia ceramic | Dentsply Sirona (York, USA) |
| Monobond S | Ivoclar Vivadent (Schaan, Liechtenstein) |
| Monobond Etch & Prime | Ivoclar Vivadent (Schaan, Liechtenstein) |
| Transbond™ MIP | 3 M ESPE (Neuss, Germany) |
| Light Bond™ | Reliance Orthodontic Products Inc. (Illinois, USA) |
| Optima 10 LED | BA International Ltd. (Northampton, UK) |
| G4™ Nickel Titanium Archwires 0,14 | OrthoForce (Levallois-Perret, France) |
| Rubber ligatures | SmileDental® (Ratingen, Germany) |
Fig. 2Shear bond strength between brackets and dental ceramic using Monobond S or Monobond Etch & Prime with/without activation of brackets using a 0.14-nickel titanium wire
Results of shear bond tests in mean, standard deviation and coefficient of variation
| Monobond S non-activated | Monobond S activated | Monobond Etch&Prime non-activated | Monobond Etch&Prime activated |
|---|---|---|---|
| mean: 0.73 | mean: 0.33 | mean: 13.66 | mean: 14.53 |
| standard deviation: 1.71 | standard deviation: 1.31 | standard deviation: 5.97 | standard deviation: 6.22 |
| coefficient of variation:2.3 | coefficient of variation: 3.9 | coefficient of variation: 0.4 | coefficient of variation: 0.4 |
Adhesive Remnant Index indicating cement residues on the ceramic surface; ARI 0: no cement residues on the ceramic surface, ARI 1: less than 50% of cement residues on the ceramic surface, ARI 2: more than 50% of cement residues on the ceramic surface, ARI 3: ceramic surface completely covered with cement
| ARI 0 | ARI 1 | ARI 2 | ARI 3 | |
|---|---|---|---|---|
| Monobond S | 119 | 1 | 0 | 0 |
| Monobond Etch & Prime | 114 | 6 | 0 | 0 |
Fig. 3Scanning electron microscopy images of three randomized samples for each group. No signs of fracture could be detected on the ceramic surfaces, regardless of both the primer and the activation. Residues of the cement are only visible on the bracket basis, regardless of both the primer and the activation