Literature DB >> 30907196

Fecal immunochemical test in cancer screening - colonoscopy outcome in FIT positives and negatives.

Hanna Ribbing Wilén1,2, Johannes Blom3, Jonas Höijer4, Gaya Andersson5, Christian Löwbeer5,6, Rolf Hultcrantz7.   

Abstract

Objectives: Fecal immunochemical test (FIT) is used in colorectal cancer (CRC) screening, but evaluations of multiple sample strategies in colonoscopy screening cohorts are rare. The aim of this study was to assess accuracy of FIT for advanced neoplasia (AN) with two fecal samples in a colonoscopy screening cohort. Materials and methods: The study comprised 1155 participants of the colonoscopy arm in SCREESCO (Screening of Swedish Colons, NCT02078804), a randomized controlled study on CRC screening of 60-year-olds from the Swedish average-risk population. Participants provided two FIT samples prior to colonoscopy. First sample, mean of two, and any of the two samples above cut off level were assessed. Colonoscopy findings (CRC, advanced adenoma (AA), AN (CRC + AA) and adenoma characteristics) were evaluated in uni- and multivariable analysis in relation to FIT positivity (at ≥10 µg hemoglobin (Hb)/g).
Results: Of 1155 invited, 806 (416 women, 390 men) participated. CRC, AA and non-AA were found in one (0.1%), 80 (9.9%) and 145 (18%), respectively. Sensitivity and specificity for AN were 20%/93%, 25%/92% and 26%/89% for first, mean of two and any of the two samples respectively at cut off level 10 µg/g, corresponding to 60 (74%)-65 (80%) participants with missed AN. The difference in sensitivity between screening strategies was non-significant. The specificity for first sample was significantly higher than for any of the two samples at cut off 10 µg/g (p = .02) and 20 µg/g (p = .04). FIT positivity in participants with adenoma was associated with pedunculated shape (p = .007) and high-risk dysplasia (p = .009). Conclusions: In an average-risk colonoscopy screening cohort of 60-year-olds, sensitivity for AN was modest and did not increase when using two samples instead of one. FIT predominantly detected adenomas with pedunculated shape and high-risk dysplasia, and participants with flat or broad based adenomas may thus be missed in screening.

Entities:  

Keywords:  Colorectal cancer; adenoma; colonoscopy; fecal immunochemical test; screening

Mesh:

Substances:

Year:  2019        PMID: 30907196     DOI: 10.1080/00365521.2019.1585569

Source DB:  PubMed          Journal:  Scand J Gastroenterol        ISSN: 0036-5521            Impact factor:   2.423


  5 in total

Review 1.  Guaiac-based faecal occult blood tests versus faecal immunochemical tests for colorectal cancer screening in average-risk individuals.

Authors:  Esmée J Grobbee; Pieter Ha Wisse; Eline H Schreuders; Aafke van Roon; Leonie van Dam; Ann G Zauber; Iris Lansdorp-Vogelaar; Wichor Bramer; Sarah Berhane; Jonathan J Deeks; Ewout W Steyerberg; Monique E van Leerdam; Manon Cw Spaander; Ernst J Kuipers
Journal:  Cochrane Database Syst Rev       Date:  2022-06-06

2.  A True Positive and a False Negative? The Dilemma of Negative Colonoscopy After a Positive Fecal Occult Blood Test.

Authors:  J S Hunt; C Cock; E L Symonds
Journal:  Dig Dis Sci       Date:  2021-05-03       Impact factor: 3.199

3.  Stage-Specific Sensitivity of Fecal Immunochemical Tests for Detecting Colorectal Cancer: Systematic Review and Meta-Analysis.

Authors:  Tobias Niedermaier; Yesilda Balavarca; Hermann Brenner
Journal:  Am J Gastroenterol       Date:  2020-01       Impact factor: 12.045

4.  Detection of advanced colorectal neoplasia and relative colonoscopy workloads using quantitative faecal immunochemical tests: an observational study exploring the effects of simultaneous adjustment of both sample number and test positivity threshold.

Authors:  Graeme P Young; Richard J Woodman; Erin Symonds
Journal:  BMJ Open Gastroenterol       Date:  2020-09

Review 5.  Aspects of colorectal cancer screening, methods, age and gender.

Authors:  R Hultcrantz
Journal:  J Intern Med       Date:  2020-09-14       Impact factor: 8.989