Literature DB >> 30888620

Three-dimensional batch electrochemical coagulation (ECC) of health care facility wastewater-clean water reclamation.

Sujit Singh1, Shivaswamy Mahesh2, Mahesh Sahana2.   

Abstract

Three-dimensional (3D) batch ECC of raw health care facility wastewater (HCFWW) was adopted using stainless steel (SS) and aluminum (Al) scrap metal particle electrodes. ECC treatment was focused on priority quality parameters viz., chemical oxygen demand (COD), color, and other important water quality parameters. Sludge settling and filterability for post-ECC slurry were investigated after ECC. COD removals of 87.56 and 87.2% were achieved for current densities (CD) 83.33 and 125 A/m2 using SS-3D electrodes, and similarly, 86.99 and 86.23% COD removal for Al-3D electrodes. Simultaneously, color removals were 88.50 and 87.60% for CD 166.66 A/m2 (4A) using SS and Al-3D electrodes. Water quality parameters viz., nitrate, phosphates, and sulfate were also removed by 93.18%, 96.83%, and 41.07% for SS-3D electrodes, while Al-3D electrodes showed 93.15%, 96.72%, and 25.94% removal. Post-ECC slurry settling was good for all the applied CD using SS-3D electrodes generating dense and sturdy flocs. Al-3D electrodes showed excellent floc settling properties. SS-3D electrode flocs displayed good filterability at 1A with α: 2.497 × 1011 m kg-1 and Rm 1.946 × 1010 m-1. Post-ECC slurry using Al-3D electrodes were viscous causing delayed filterability giving α: 1.1760 × 1011 m kg-1 and Rm 1.504 × 109 m-1 for 3A. E. coli was destroyed by 97 and 98% for 2A and 3A respectively. Clear water reclamation of 85-90% and pollutants/contaminants removed within a short HRT of 75 min proved the effectiveness of adopting 3D-ECC for treating raw HCFWW.

Entities:  

Keywords:  Chemical oxygen demand; Color; Healthcare facility wastewater; Settling-filterability; Three-dimensional electrochemical coagulation

Mesh:

Substances:

Year:  2019        PMID: 30888620     DOI: 10.1007/s11356-019-04789-9

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  19 in total

1.  Removal of nitrate from water by electroreduction and electrocoagulation.

Authors:  A Savas Koparal; Ulker Bakir Oğütveren
Journal:  J Hazard Mater       Date:  2002-01-04       Impact factor: 10.588

2.  Application of response surface methodology to the treatment landfill leachate in a three-dimensional electrochemical reactor.

Authors:  Hui Zhang; Yanli Li; Xiaogang Wu; Yanjun Zhang; Daobin Zhang
Journal:  Waste Manag       Date:  2010-05-21       Impact factor: 7.145

3.  Ecotoxicological risk assessment of hospital wastewater: a proposed framework for raw effluents discharging into urban sewer network.

Authors:  E Emmanuel; Y Perrodin; G Keck; J-M Blanchard; P Vermande
Journal:  J Hazard Mater       Date:  2005-01-14       Impact factor: 10.588

4.  Behavior of tetracycline and sulfamethoxazole and their corresponding resistance genes in three-dimensional biofilm-electrode reactors with low current.

Authors:  Shuai Zhang; Hai L Song; Xiao L Yang; Xi Z Long; Xi Liu; Tong Q Chen
Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng       Date:  2016-12-07       Impact factor: 2.269

5.  Continuous electrochemical oxidation of methyl orange waste water using a three-dimensional electrode reactor.

Authors:  Zhigang Liu; Feifei Wang; Yansheng Li; Tianlong Xu; Shaomin Zhu
Journal:  J Environ Sci (China)       Date:  2011-06       Impact factor: 5.565

6.  Comparison of different aerobic granular sludge types for activated sludge nitrification bioaugmentation potential.

Authors:  Bryce A Figdore; H David Stensel; Mari-Karoliina H Winkler
Journal:  Bioresour Technol       Date:  2017-11-06       Impact factor: 9.642

7.  High rate treatment of hospital wastewater using activated sludge process induced by high-frequency ultrasound.

Authors:  Nasim Karami; Parviz Mohammadi; Aliakbar Zinatizadeh; Farzaneh Falahi; Nasrin Aghamohammadi
Journal:  Ultrason Sonochem       Date:  2018-04-19       Impact factor: 7.491

8.  Iron removal, energy consumption and operating cost of electrocoagulation of drinking water using a new flow column reactor.

Authors:  Khalid S Hashim; Andy Shaw; Rafid Al Khaddar; Montserrat Ortoneda Pedrola; David Phipps
Journal:  J Environ Manage       Date:  2016-12-21       Impact factor: 6.789

9.  Removal of color from real dyeing wastewater by Electro-Fenton technology using a three-dimensional graphite cathode.

Authors:  Chih-Ta Wang; Jen-Lu Hu; Wei-Lung Chou; Yi-Ming Kuo
Journal:  J Hazard Mater       Date:  2007-07-13       Impact factor: 10.588

10.  Investigating the removal of some pharmaceutical compounds in hospital wastewater treatment plants operating in Saudi Arabia.

Authors:  Hamed Al Qarni; Philip Collier; Juliette O'Keeffe; Joseph Akunna
Journal:  Environ Sci Pollut Res Int       Date:  2016-03-21       Impact factor: 4.223

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.