Cardiac output monitoring with thermodilution pulse-contour analysis vs. non-invasive pulse-contour analysis.

M Boisson1, M E Poignard1, B Pontier1, O Mimoz2, B Debaene1, D Frasca1.   

Abstract

Intravenous fluid boluses guided by changes in stroke volume improve some outcomes after major surgery, but invasive measurments may limit use. From October 2016 to May 2018, we compared the agreement and trending ability of a photoplethysmographic device (Clearsight) with a PiCCO, calibrated by thermodilution, for haemodynamic variables in 20 adults undergoing major elective surgery. We analysed 4519 measurement pairs, including before and after 68 boluses of 250 ml crystalloid. The bias and precision of stroke volume measurement by Clearsight were -0.89 ± 4.78 ml compared with the invasive pulse-contour cardiac output device. The coefficient of agreement for stroke volume variation after fluid boluses between the two devices was 0.79 ('strong'). Fluid boluses that increased stroke volume by ≥ 10% increased mean absolute volume (SD) and mean percentage (SD) stroke volume measurements similarly for the invasive pulse-contour cardiac output and Clearsight devices: 9 (4) ml vs. 8 (4) ml and 16% (8%) vs. 15% (10%), respectively, p > 0.05. The non-invasive Clearsight pulse-contour analysis was similar to an invasive pulse-contour device in measuring absolute and changing stroke volumes during major surgery.
© 2019 Association of Anaesthetists.

Entities:  

Keywords:  cardiac ouput; intra-operative monitoring; major surgery LV pressure-volume relations: impact of preload; stroke volume

Mesh:

Year:  2019        PMID: 30888055     DOI: 10.1111/anae.14638

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

1.  Simulating Radial Pressure Waveforms with a Mock Circulatory Flow Loop to Characterize Hemodynamic Monitoring Systems.

Authors:  Anna Packy; Gavin A D'Souza; Masoud Farahmand; Luke Herbertson; Christopher G Scully
Journal:  Cardiovasc Eng Technol       Date:  2021-09-01       Impact factor: 2.305

2.  Accuracy of noninvasive continuous arterial pressure monitoring using ClearSight during one-lung ventilation.

Authors:  Sang-Wook Lee; Sangho Lee; Hyungtae Kim; Yun-Jong Kim; Mihyeon Kim; Jeong-Hyun Choi
Journal:  Medicine (Baltimore)       Date:  2021-03-19       Impact factor: 1.817

3.  Noninvasive cardiac output measurements are inaccurate in patients with severe aortic valve stenosis undergoing transcatheter aortic valve implantation.

Authors:  Musashi Yahagi; Kyuma Omi; Takuma Maeda
Journal:  Korean J Anesthesiol       Date:  2021-10-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.