Measurement of changes in optic nerve sheath diameter using ultrasound and computed tomography scan before and after the ventriculoperitoneal shunt surgery in patients with hydrocephalus - A prospective observational trial.

Deepak Bhandari1, Prasanna Udupi Bidkar2, S Adinarayanan3, K Narmadhalakshmi4, S Srinivasan5.   

Abstract

BACKGROUND: The standard methods for measuring intracranial pressure (ICP) are invasive in nature. Non invasive methods such as ONSD may help circumvent these complications and may serve as a surrogate marker for increased ICP. The primary aim of this study was to assess the ONSD (optic nerve sheath diameter) changes using ultrasonography (USG) and computed tomography (CT) scan in hydrocephalus patients before and after the insertion of VP shunt.
MATERIALS AND METHODS: A prospective observational study was conducted among 69 patients undergoing VP shunt surgery between the ages of 2 to 60 years. ONSD variation was measured by USG and CT scan both before and after the surgery. The difference in the pre-operative and post-operative ONSD measurement was analyzed using a paired t-test. Whereas, the measurements of ONSD were compared for agreement between two modalities (USG and CT) using Interclass correlation (ICC) and Bland Altman graph plot.
RESULTS: Among 69 patients 38 were males, 31 were females and 12 were under the age of 10 years. In the adult group, average preoperative and postoperative ONSD measurement by USG was 5.80 ± 0.63 mm and 4.52 ± 0.72 (p < 0.001) and by CT was 5.77 ± 0.83 mm and 4.49 ± 0.76 mm (p < 0.001) respectively. Similarly, in the pediatric population, average preoperative and postoperative ONSD measurement by USG was found to be 4.76 ± 1.14 mm and 3.90 ± 1.08 mm and by CT was found to be 4.75+/-1.11 mm and 3.85 ± 1.09 mm respectively (p <0.001).
CONCLUSION: In patients with hydrocephalus undergoing VP shunt surgery, we found a significant reduction in ONSD after the shunt insertion in both pediatric and adult population. We also found a good correlation between the USG and CT scan measurements of ONSD.

Entities:  

Keywords:  Optic nerve sheath diameter; Ultrasonography; Ventriculo-peritoneal shunt

Mesh:

Year:  2019        PMID: 30880478     DOI: 10.1080/02688697.2019.1576856

Source DB:  PubMed          Journal:  Br J Neurosurg        ISSN: 0268-8697            Impact factor:   1.596


  4 in total

1.  Quantitative Evans index estimation using ultrasonographic measurement of the optic nerve sheath diameter in supine and upright position.

Authors:  Mindaugas Urbonas; Nijole Raskauskiene; Vytenis Deltuva; Adomas Bunevicius
Journal:  Acta Neurochir (Wien)       Date:  2022-05-21       Impact factor: 2.816

Review 2.  Is Ocular Sonography a Reliable Method for the Assessment of Elevated Intracranial Pressure in Children?

Authors:  Dincer Yildizdas; Nagehan Aslan
Journal:  J Pediatr Intensive Care       Date:  2020-09-07

3.  Predictive Utility of Changes in Optic Nerve Sheath Diameter after Cardiac Arrest for Neurologic Outcomes.

Authors:  Heekyung Lee; Joonkee Lee; Hyungoo Shin; Changsun Kim; Hyuk-Joong Choi; Bo-Seung Kang
Journal:  Int J Environ Res Public Health       Date:  2021-06-18       Impact factor: 3.390

4.  Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: a systematic review and meta-analysis.

Authors:  Lisandro Montorfano; Qian Yu; Stephen J Bordes; Shankarapryan Sivanushanthan; Raul J Rosenthal; Miguel Montorfano
Journal:  Ultrasound J       Date:  2021-07-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.