Literature DB >> 30876089

Interferometric delay tracking for low-noise Mach-Zehnder-type scanning measurements.

Wolfgang Schweinberger, Lenard Vamos, Jia Xu, Syed A Hussain, Christoph Baune, Sebastian Rode, Ioachim Pupeza.   

Abstract

Precise delay control is of paramount importance in optical pump-probe measurements. Here, we report on a high-precision delay tracking technique for mechanical scanning measurements in a Mach-Zehnder interferometer configuration. The setup employs a 1.55-µm continuous-wave laser beam propagating along the interferometer arms. Sinusoidal phase modulation at 30 MHz, and demodulation of the interference signal at the fundamental frequency and its second harmonic, enables delay tracking with sampling rates of up to 10 MHz. At an interferometer arm length of 1 m, root-mean-square error values of the relative delay tracking below 10 attoseconds for both stationary and mechanically scanned (0.2 mm/s) operation are demonstrated. By averaging several scans, a precision of the delay determination better than 1 as is reached. We demonstrate this performance with a mechanical chopper periodically interrupting one of the interferometer arms, which opens the door to the combination of high-sensitivity lock-in detection with (sub-)attosecond-precision relative delay determination.

Year:  2019        PMID: 30876089     DOI: 10.1364/OE.27.004789

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  3 in total

1.  Field-resolved infrared spectroscopy of biological systems.

Authors:  Ioachim Pupeza; Marinus Huber; Michael Trubetskov; Wolfgang Schweinberger; Syed A Hussain; Christina Hofer; Kilian Fritsch; Markus Poetzlberger; Lenard Vamos; Ernst Fill; Tatiana Amotchkina; Kosmas V Kepesidis; Alexander Apolonski; Nicholas Karpowicz; Vladimir Pervak; Oleg Pronin; Frank Fleischmann; Abdallah Azzeer; Mihaela Žigman; Ferenc Krausz
Journal:  Nature       Date:  2020-01-01       Impact factor: 49.962

2.  Sub-optical-cycle light-matter energy transfer in molecular vibrational spectroscopy.

Authors:  Martin T Peschel; Maximilian Högner; Theresa Buberl; Daniel Keefer; Regina de Vivie-Riedle; Ioachim Pupeza
Journal:  Nat Commun       Date:  2022-10-06       Impact factor: 17.694

3.  Multi-octave, CEP-stable source for high-energy field synthesis.

Authors:  Ayman Alismail; Haochuan Wang; Gaia Barbiero; Najd Altwaijry; Syed Ali Hussain; Volodymyr Pervak; Wolfgang Schweinberger; Abdallah M Azzeer; Ferenc Krausz; Hanieh Fattahi
Journal:  Sci Adv       Date:  2020-02-14       Impact factor: 14.136

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.