Literature DB >> 30864663

S VALUES FOR NEUROIMAGING PROCEDURES ON KOREAN PEDIATRIC AND ADULT HEAD COMPUTATIONAL PHANTOMS.

Daphnée Villoing1, Ae-Kyoung Lee2, Hyung-do Choi2, Choonsik Lee1.   

Abstract

Over the past decades, the application of single-photon emission computed tomography and positron emission tomography in neuroimaging has markedly increased. In the current study, we used a series of Korean computational head phantoms with detailed cranial structures for 6-, 9-, 12-, 15-y-old children and adult and a Monte Carlo transport code, MCNPX, to calculate age-dependent specific absorbed fraction (SAF) for mono-energetic electrons ranging from 0.01 to 4 MeV and S values for seven radionuclides widely used in nuclear medicine neuroimaging for the combination of ten source and target regions. Compared to the adult phantom, the 6-y phantom showed up to 1.7-fold greater SAF (cerebellum < cerebellum) and up to 1.4-fold greater S values (vitreous body < lens) for 123I. The electron SAF data, combined with our previous photon SAF data, will facilitate absorbed dose calculations for various cranial structures in patients undergoing neuroimaging procedures. Published by Oxford University Press 2019. This work is written by (a) US Government employee(s) and is in the public domain in the US.

Entities:  

Mesh:

Year:  2019        PMID: 30864663      PMCID: PMC7304518          DOI: 10.1093/rpd/ncy287

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  13 in total

1.  MIRD pamphlet No. 21: a generalized schema for radiopharmaceutical dosimetry--standardization of nomenclature.

Authors:  Wesley E Bolch; Keith F Eckerman; George Sgouros; Stephen R Thomas
Journal:  J Nucl Med       Date:  2009-03       Impact factor: 10.057

2.  ICRP Publication 107. Nuclear decay data for dosimetric calculations.

Authors:  K Eckerman; A Endo
Journal:  Ann ICRP       Date:  2008

3.  S values for 131I based on the ICRP adult voxel phantoms.

Authors:  Stephanie Lamart; Steven L Simon; Andre Bouville; Brian E Moroz; Choonsik Lee
Journal:  Radiat Prot Dosimetry       Date:  2015-03-31       Impact factor: 0.972

Review 4.  Radiation risk in nuclear medicine.

Authors:  S James Adelstein
Journal:  Semin Nucl Med       Date:  2014-05       Impact factor: 4.446

Review 5.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

6.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom.

Authors:  W S Snyder; H L Fisher; M R Ford; G G Warner
Journal:  J Nucl Med       Date:  1969-08       Impact factor: 10.057

7.  KOREAN PEDIATRIC AND ADULT HEAD COMPUTATIONAL PHANTOMS AND APPLICATION TO PHOTON SPECIFIC ABSORBED FRACTIONS CALCULATIONS.

Authors:  Daphnée Villoing; Dayton McMillan; Kwang Pyo Kim; Ae-Kyoung Lee; Hyung-do Choi; Choonsik Lee
Journal:  Radiat Prot Dosimetry       Date:  2017-11-01       Impact factor: 0.972

8.  Comparison of internal dosimetry factors for three classes of adult computational phantoms with emphasis on I-131 in the thyroid.

Authors:  Stephanie Lamart; Andre Bouville; Steven L Simon; Keith F Eckerman; Dunstana Melo; Choonsik Lee
Journal:  Phys Med Biol       Date:  2011-11-21       Impact factor: 3.609

9.  S-values calculated from a tomographic head/brain model for brain imaging.

Authors:  Tsi-Chian Chao; X George Xu
Journal:  Phys Med Biol       Date:  2004-11-07       Impact factor: 3.609

10.  Basic anatomical and physiological data for use in radiological protection: reference values. A report of age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. ICRP Publication 89.

Authors: 
Journal:  Ann ICRP       Date:  2002
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.