Literature DB >> 30856647

Load-Bearing Capacity of Posterior CAD/CAM Implant-Supported Fixed Partial Dentures Fabricated with Different Esthetic Materials.

Ami Amelya, Jong-Eun Kim, Chang-Woo Woo, Jamiyandorj Otgonbold, Keun-Woo Lee.   

Abstract

PURPOSE: To compare the load-bearing capacity after long-term use (5-year simulation) of posterior three-unit implant-supported fixed partial dentures (FPDs) fabricated with different esthetic materials.
MATERIALS AND METHODS: A total of 20 specimens fabricated from one design file using CAD/CAM were divided into four groups: polyetherketoneketone (PEKK) veneered with composite resin (CR); PEKK veneered with lithium disilicate (LD); zirconia veneered with fluorapatite (FA); and monolithic zirconia. Samples were placed into a chewing simulator with simultaneous thermocycling. The fracture load after aging was measured using the universal testing machine with load on the central fossa of the pontic.
RESULTS: FPDs fabricated with PEKK + LD had significantly higher fracture load (1,526.56 [SD 95.54] N) compared to PEKK + CR (1,069.54 [SD 67.94] N) (P < .05). FPDs fabricated with zirconia materials had significantly higher fracture load compared to PEKK materials (P < .05). There was no significant difference between monolithic zirconia and zirconia + FA (P > .05).
CONCLUSION: FPDs fabricated with PEKK + LD were superior to PEKK + CR. These materials can be promising alternatives for use as implant-supported FPD materials in the high-stress-bearing posterior region. Zirconia + FA can be an alternative to monolithic zirconia in cases that require more esthetics.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30856647     DOI: 10.11607/ijp.6128

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  6 in total

Review 1.  Polyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prostheses.

Authors:  Hatim Alqurashi; Zohaib Khurshid; Azeem Ul Yaqin Syed; Syed Rashid Habib; Dinesh Rokaya; Muhammad Sohail Zafar
Journal:  J Adv Res       Date:  2020-09-18       Impact factor: 10.479

2.  Tooth-Colored CAD/CAM Materials for Application in 3-Unit Fixed Dental Prostheses in the Molar Area: An Illustrated Clinical Comparison.

Authors:  Angelika Rauch; Sebastian Hahnel; Elena Günther; Wolfgang Bidmon; Oliver Schierz
Journal:  Materials (Basel)       Date:  2020-12-08       Impact factor: 3.623

3.  Impact of the Veneering Technique and Framework Material on the Failure Loads of All-Ceramic Computer-Aided Design/Computer-Aided Manufacturing Fixed Partial Dentures.

Authors:  Sebastian Hinz; Tobias Bensel; Wolfgang Bömicke; Anders Henningsen; Judith Rudolph; Arne F Boeckler
Journal:  Materials (Basel)       Date:  2022-01-19       Impact factor: 3.623

4.  A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition.

Authors:  Nahla Gamal Elhelbawy; Rehab F Ghouraba; Fatma A Hasaneen
Journal:  Int J Biomater       Date:  2022-02-21

Review 5.  New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies.

Authors:  Pinar Cevik; Martin Schimmel; Burak Yilmaz
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

6.  Mechanical Response of PEKK and PEEK As Frameworks for Implant-Supported Full-Arch Fixed Dental Prosthesis: 3D Finite Element Analysis.

Authors:  Regina Furbino Villefort; Pedro Jacy Santos Diamantino; Sandra Lúcia Ventorin von Zeidler; Alexandre Luiz Souto Borges; Laís Regiane Silva-Concílio; Guilherme deSiqueira Ferreira Anzaloni Saavedra; João Paulo Mendes Tribst
Journal:  Eur J Dent       Date:  2021-09-24
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.