Literature DB >> 30852982

Assessment of the CoaguChek-XS portable prothrombin time point-of-care analyzer for horses.

Noa Berlin1,2,3,4, Efrat Kelmer1,2,3,4, Gilad Segev1,2,3,4, Itamar Aroch1,2,3,4, Gal Kelmer1,2,3,4.   

Abstract

Coagulopathies in horses are common and potentially life-threatening. In equine field medicine, a portable point-of-care (POC) prothrombin time (PT) testing device could be useful to identify early changes in extrinsic clotting. The CoaguChek-XS (Roche Diagnostics) is a small, portable POC PT analyzer used in human medicine. Our preliminary study assessed the suitability of CoaguChek-XS for testing PT in horses and established the PT reference interval (PT RI) in healthy horses using this instrument. Blood samples collected from 102 healthy and ill horses were analyzed with the CoaguChek-XS and compared to a semi-automated coagulometric analyzer (SACA) as the gold standard. There was a significant positive correlation between the 2 measurement methods ( r = 0.765, p < 0.01), and very good agreement, with 97% of the samples falling within limits of agreement. The mean CoaguChek-XS PT coefficient of variation was 0.8%, indicating high precision. With high precision and good agreement with the coagulometric PT, the CoaguChek-XS should be further validated for PT measurement in horses.

Entities:  

Keywords:  clotting; coagulation; equine; hemostasis; point-of-care testing

Mesh:

Year:  2019        PMID: 30852982      PMCID: PMC6838704          DOI: 10.1177/1040638719832340

Source DB:  PubMed          Journal:  J Vet Diagn Invest        ISSN: 1040-6387            Impact factor:   1.279


  21 in total

1.  A comparison between capillary and venous blood international normalized ratio determinations in a portable prothrombin time device.

Authors:  A M van den Besselaar; J Meeuwisse-Braun; H Schaefer-van Mansfeld; C van Rijn; E Witteveen
Journal:  Blood Coagul Fibrinolysis       Date:  2000-09       Impact factor: 1.276

2.  ASVCP guidelines: allowable total error guidelines for biochemistry.

Authors:  Kendal E Harr; Bente Flatland; Mary Nabity; Kathleen P Freeman
Journal:  Vet Clin Pathol       Date:  2013-12       Impact factor: 1.180

3.  ASVCP reference interval guidelines: determination of de novo reference intervals in veterinary species and other related topics.

Authors:  Kristen R Friedrichs; Kendal E Harr; Kathy P Freeman; Balazs Szladovits; Raquel M Walton; Kirstin F Barnhart; Julia Blanco-Chavez
Journal:  Vet Clin Pathol       Date:  2012-12       Impact factor: 1.180

4.  Assessment of a portable prothrombin time analyzer (CoaguChek-XS) in dogs.

Authors:  Efrat Kelmer; Gilad Segev; Carolina Codner; Yaron Bruchim; Sigal Klainbart; Itamar Aroch
Journal:  J Vet Emerg Crit Care (San Antonio)       Date:  2014-07-15

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Evaluation of the new method Coaguchek for the determination of prothrombin time from capillary blood: comparison with Thrombotest on KC-1.

Authors:  S Kapiotis; P Quehenberger; W Speiser
Journal:  Thromb Res       Date:  1995-03-15       Impact factor: 3.944

7.  ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine.

Authors:  Bente Flatland; Kathleen P Freeman; Linda M Vap; Kendal E Harr
Journal:  Vet Clin Pathol       Date:  2013-12       Impact factor: 1.180

8.  Results of the performance verification of the CoaguChek XS system.

Authors:  W Plesch; T Wolf; N Breitenbeck; L D Dikkeschei; A Cervero; P L Perez; A M H P van den Besselaar
Journal:  Thromb Res       Date:  2008-06-27       Impact factor: 3.944

Review 9.  Coagulopathy in the equine critical care patient.

Authors:  Barbara L Dallap
Journal:  Vet Clin North Am Equine Pract       Date:  2004-04       Impact factor: 1.792

10.  Pathologic findings in equine muscle (excluding polysaccharide storage): a necropsy study.

Authors:  Beth A Valentine
Journal:  J Vet Diagn Invest       Date:  2008-09       Impact factor: 1.279

View more
  1 in total

1.  Coagulation testing: Comparison of portable (CoaguChek® XS) and automated coagulation analyzer in healthy cats.

Authors:  Sireeporn Tonthong; Jetsada Rungpupradit
Journal:  Vet World       Date:  2020-11-27
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.