Literature DB >> 30849426

Intraocular pressure measurement after corneal transplantation.

Bernardo de Padua Soares Bezerra1, Elsie Chan2, Rahul Chakrabarti1, Rasik B Vajpayee3.   

Abstract

Measurement of intraocular pressure is an integral part of a comprehensive ocular examination, especially after a surgical intervention that can affect aqueous humor flow dynamics. Most of the intraocular pressure measurement devices are designed for "normal" corneas and may not be accurate in eyes after corneal transplantation where there is altered corneal morphology. Raised intraocular pressure and glaucoma are known postoperative complications after transplantation, and therefore, accurate intraocular pressure measurement is essential. We review the effect of abnormal corneal curvature, corneal thickness, and different biomechanical properties in the context of corneal transplantation on intraocular pressure measurement using a number of devices.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  DALK; DSAEK; endothelial keratoplasty; glaucoma; intraocular pressure; intraocular pressure measurement; keratoplasty; lamellar keratoplasty; penetrating keratoplasty; tonometry

Mesh:

Year:  2019        PMID: 30849426     DOI: 10.1016/j.survophthal.2019.02.011

Source DB:  PubMed          Journal:  Surv Ophthalmol        ISSN: 0039-6257            Impact factor:   6.048


  3 in total

1.  Corneal biomechanics and intraocular pressure assessment after penetrating keratoplasty for non keratoconic patients, long term results.

Authors:  Mohamed Samy Abd Elaziz; Hoda Mohamed Elsobky; Adel Galal Zaky; Eslam Ahmed Maher Hassan; Mahmoud Tawfik KhalafAllah
Journal:  BMC Ophthalmol       Date:  2019-08-07       Impact factor: 2.209

2.  Modification of Corneal Biomechanics and Intraocular Pressure Following Non-Penetrating Deep Sclerectomy.

Authors:  María Dolores Díaz-Barreda; Ignacio Sánchez-Marín; Ana Boned-Murillo; Itziar Pérez-Navarro; Juana Martínez; Elena Pardina-Claver; Diana Pérez; Francisco Javier Ascaso; Juan Ibáñez
Journal:  J Clin Med       Date:  2022-02-24       Impact factor: 4.241

3.  Early intraocular pressure changes following different keratoplasty techniques and association with cornea parameters and anterior chamber depth.

Authors:  Gulsah Gumus; Cigdem Altan; Yusuf Yildirim; Nilay Kandemir Beşek; Selim Genç; Ahmet Kirgiz; Gonul Karatas Durusoy; Alper Ağca
Journal:  Ther Adv Ophthalmol       Date:  2022-03-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.