Nadine Wong Yuzhen1, Sarah Barrett1. 1. Applied Radiation Therapy Trinity, Discipline of Radiation Therapy, Trinity College Dublin, Ireland.
Abstract
AIM: To review the literature on auto-contouring methods of lung tumour volumes on four-dimensional computed tomography (4DCT). BACKGROUND: Manual delineation of lung tumour on 4DCT has been the gold standard in clinical practice. However, it is resource intensive due to the high volume of data which results in longer contouring duration and uncertainties in defining target. Auto-contouring may present as an attractive alternative by decreasing manual inputs required, thus improving the contouring process. This review aims to assess the accuracy, variability and contouring duration of automatic contouring compared with manual contouring in lung cancer on 4DCT datasets. MATERIALS AND METHODS: A search and review of literature were conducted to identify studies regarding lung tumour contouring on 4DCT. Manual and auto-contours were assessed and compared based on accuracy, variability and contouring duration. RESULTS: Thirteen studies were included in this review and their results were compared. Accuracy of auto-contours was found to be comparable to manual contours. Auto-contouring resulted in lesser inter-observer variation when compared to manual contouring, however there was no significant reduction in intra-observer variability. Additionally, contouring duration was reduced with auto-contouring although long computation time could present as a bottleneck. CONCLUSION: Auto-contouring is reliable and efficient, producing accurate contours with better consistency compared to manual contours. However, manual inputs would still be required both before and after auto-propagation.
AIM: To review the literature on auto-contouring methods of lung tumour volumes on four-dimensional computed tomography (4DCT). BACKGROUND: Manual delineation of lung tumour on 4DCT has been the gold standard in clinical practice. However, it is resource intensive due to the high volume of data which results in longer contouring duration and uncertainties in defining target. Auto-contouring may present as an attractive alternative by decreasing manual inputs required, thus improving the contouring process. This review aims to assess the accuracy, variability and contouring duration of automatic contouring compared with manual contouring in lung cancer on 4DCT datasets. MATERIALS AND METHODS: A search and review of literature were conducted to identify studies regarding lung tumour contouring on 4DCT. Manual and auto-contours were assessed and compared based on accuracy, variability and contouring duration. RESULTS: Thirteen studies were included in this review and their results were compared. Accuracy of auto-contours was found to be comparable to manual contours. Auto-contouring resulted in lesser inter-observer variation when compared to manual contouring, however there was no significant reduction in intra-observer variability. Additionally, contouring duration was reduced with auto-contouring although long computation time could present as a bottleneck. CONCLUSION: Auto-contouring is reliable and efficient, producing accurate contours with better consistency compared to manual contours. However, manual inputs would still be required both before and after auto-propagation.
Entities:
Keywords:
4DCT; Automatic segmentation; Delineation; Lung cancer
Authors: Jan Van de Steene; Nadine Linthout; Johan de Mey; Vincent Vinh-Hung; Cornelia Claassens; Marc Noppen; Arjan Bel; Guy Storme Journal: Radiother Oncol Date: 2002-01 Impact factor: 6.280
Authors: A Pevsner; B Davis; S Joshi; A Hertanto; J Mechalakos; E Yorke; K Rosenzweig; S Nehmeh; Y E Erdi; J L Humm; S Larson; C C Ling; G S Mageras Journal: Med Phys Date: 2006-02 Impact factor: 4.071
Authors: Philippe Giraud; Sabine Elles; Sylvie Helfre; Yann De Rycke; Vincent Servois; Marie France Carette; Claude Alzieu; Pierre Yves Bondiau; Bernard Dubray; Emmanuel Touboul; Martin Housset; Jean Claude Rosenwald; Jean Marc Cosset Journal: Radiother Oncol Date: 2002-01 Impact factor: 6.280
Authors: Jonathan Orban de Xivry; Guillaume Janssens; Geert Bosmans; Mathieu De Craene; André Dekker; Jeroen Buijsen; Angela van Baardwijk; Dirk De Ruysscher; Benoit Macq; Philippe Lambin Journal: Radiother Oncol Date: 2007-10-23 Impact factor: 6.280
Authors: Harald Paganetti; Chris Beltran; Stefan Both; Lei Dong; Jacob Flanz; Keith Furutani; Clemens Grassberger; David R Grosshans; Antje-Christin Knopf; Johannes A Langendijk; Hakan Nystrom; Katia Parodi; Bas W Raaymakers; Christian Richter; Gabriel O Sawakuchi; Marco Schippers; Simona F Shaitelman; B K Kevin Teo; Jan Unkelbach; Patrick Wohlfahrt; Tony Lomax Journal: Phys Med Biol Date: 2021-02-26 Impact factor: 4.174