Literature DB >> 30840747

Variation in algorithm implementation across radiomics software.

Joseph J Foy1, Kayla R Robinson1, Hui Li1, Maryellen L Giger1, Hania Al-Hallaq2, Samuel G Armato1.   

Abstract

Given the increased need for consistent quantitative image analysis, variations in radiomics feature calculations due to differences in radiomics software were investigated. Two in-house radiomics packages and two freely available radiomics packages, MaZda and IBEX, were utilized. Forty 256 × 256 - pixel regions of interest (ROIs) from 40 digital mammograms were studied along with 39 manually delineated ROIs from the head and neck (HN) computed tomography (CT) scans of 39 patients. Each package was used to calculate first-order histogram and second-order gray-level co-occurrence matrix (GLCM) features. Friedman tests determined differences in feature values across packages, whereas intraclass-correlation coefficients (ICC) quantified agreement. All first-order features computed from both mammography and HN cases (except skewness in mammography) showed significant differences across all packages due to systematic biases introduced by each package; however, based on ICC values, all but one first-order feature calculated on mammography ROIs and all but two first-order features calculated on HN CT ROIs showed excellent agreement, indicating the observed differences were small relative to the feature values but the bias was systematic. All second-order features computed from the two databases both differed significantly and showed poor agreement among packages, due largely to discrepancies in package-specific default GLCM parameters. Additional differences in radiomics features were traced to variations in image preprocessing, algorithm implementation, and naming conventions. Large variations in features among software packages indicate that increased efforts to standardize radiomics processes must be conducted.

Entities:  

Keywords:  head and neck CT; mammography; radiomics; software packages; texture analysis

Year:  2018        PMID: 30840747      PMCID: PMC6278846          DOI: 10.1117/1.JMI.5.4.044505

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  33 in total

1.  Improvement in radiologists' detection of clustered microcalcifications on mammograms. The potential of computer-aided diagnosis.

Authors:  H P Chan; K Doi; C J Vyborny; R A Schmidt; C E Metz; K L Lam; T Ogura; Y Z Wu; H MacMahon
Journal:  Invest Radiol       Date:  1990-10       Impact factor: 6.016

Review 2.  Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

Authors:  Kunio Doi
Journal:  Comput Med Imaging Graph       Date:  2007-03-08       Impact factor: 4.790

3.  MaZda--a software package for image texture analysis.

Authors:  Piotr M Szczypiński; Michał Strzelecki; Andrzej Materka; Artur Klepaczko
Journal:  Comput Methods Programs Biomed       Date:  2008-10-14       Impact factor: 5.428

4.  Interobserver and intraobserver variation among experts in the diagnosis of thyroid follicular lesions with borderline nuclear features of papillary carcinoma.

Authors:  Tarik M Elsheikh; Sylvia L Asa; John K C Chan; Ronald A DeLellis; Clara S Heffess; Virginia A LiVolsi; Bruce M Wenig
Journal:  Am J Clin Pathol       Date:  2008-11       Impact factor: 2.493

Review 5.  The detection and management of unruptured intracranial aneurysms.

Authors:  J M Wardlaw; P M White
Journal:  Brain       Date:  2000-02       Impact factor: 13.501

6.  Computerized analysis of mammographic parenchymal patterns on a large clinical dataset of full-field digital mammograms: robustness study with two high-risk datasets.

Authors:  Hui Li; Maryellen L Giger; Li Lan; Jeremy Bancroft Brown; Aoife MacMahon; Mary Mussman; Olufunmilayo I Olopade; Charlene Sennett
Journal:  J Digit Imaging       Date:  2012-10       Impact factor: 4.056

7.  Variability of textural features in FDG PET images due to different acquisition modes and reconstruction parameters.

Authors:  Paulina E Galavis; Christian Hollensen; Ngoneh Jallow; Bhudatt Paliwal; Robert Jeraj
Journal:  Acta Oncol       Date:  2010-10       Impact factor: 4.089

8.  Computerized detection of colonic polyps at CT colonography on the basis of volumetric features: pilot study.

Authors:  Hiroyuki Yoshida; Yoshitaka Masutani; Peter MacEneaney; David T Rubin; Abraham H Dachman
Journal:  Radiology       Date:  2002-02       Impact factor: 11.105

9.  Dynamic contrast-enhanced texture analysis of the liver: initial assessment in colorectal cancer.

Authors:  Balaji Ganeshan; Katherine Burnand; Rupert Young; Chris Chatwin; Kenneth Miles
Journal:  Invest Radiol       Date:  2011-03       Impact factor: 6.016

10.  Computerized texture analysis of mammographic parenchymal patterns of digitized mammograms.

Authors:  Hui Li; Maryellen L Giger; Olufunmilayo I Olopade; Anna Margolis; Li Lan; Michael R Chinander
Journal:  Acad Radiol       Date:  2005-07       Impact factor: 3.173

View more
  21 in total

1.  Radiomics in nuclear medicine: robustness, reproducibility, standardization, and how to avoid data analysis traps and replication crisis.

Authors:  Alex Zwanenburg
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-06-25       Impact factor: 9.236

Review 2.  NCTN Assessment on Current Applications of Radiomics in Oncology.

Authors:  Ke Nie; Hania Al-Hallaq; X Allen Li; Stanley H Benedict; Jason W Sohn; Jean M Moran; Yong Fan; Mi Huang; Michael V Knopp; Jeff M Michalski; James Monroe; Ceferino Obcemea; Christina I Tsien; Timothy Solberg; Jackie Wu; Ping Xia; Ying Xiao; Issam El Naqa
Journal:  Int J Radiat Oncol Biol Phys       Date:  2019-01-31       Impact factor: 7.038

3.  Cross-Vendor CT Image Data Harmonization Using CVH-CT.

Authors:  Md Selim; Jie Zhang; Baowei Fei; Guo-Qiang Zhang; Gary Yeeming Ge; Jin Chen
Journal:  AMIA Annu Symp Proc       Date:  2022-02-21

Review 4.  Radiomic Signatures Associated with CD8+ Tumour-Infiltrating Lymphocytes: A Systematic Review and Quality Assessment Study.

Authors:  Syafiq Ramlee; David Hulse; Kinga Bernatowicz; Raquel Pérez-López; Evis Sala; Luigi Aloj
Journal:  Cancers (Basel)       Date:  2022-07-27       Impact factor: 6.575

5.  Benchmarking Various Radiomic Toolkit Features While Applying the Image Biomarker Standardization Initiative toward Clinical Translation of Radiomic Analysis.

Authors:  Mingxi Lei; Bino Varghese; Darryl Hwang; Steven Cen; Xiaomeng Lei; Bhushan Desai; Afshin Azadikhah; Assad Oberai; Vinay Duddalwar
Journal:  J Digit Imaging       Date:  2021-09-20       Impact factor: 4.903

6.  Effects of variability in radiomics software packages on classifying patients with radiation pneumonitis.

Authors:  Joseph J Foy; Samuel G Armato; Hania A Al-Hallaq
Journal:  J Med Imaging (Bellingham)       Date:  2020-02-21

7.  Effect of an iterative reconstruction quantum noise reduction technique on computed tomography radiomic features.

Authors:  Joseph J Foy; Mena Shenouda; Sahar Ramahi; Samuel Armato; Daniel Thomas Ginat
Journal:  J Med Imaging (Bellingham)       Date:  2020-12-30

Review 8.  The Role of Radiomics in Lung Cancer: From Screening to Treatment and Follow-Up.

Authors:  Radouane El Ayachy; Nicolas Giraud; Paul Giraud; Catherine Durdux; Philippe Giraud; Anita Burgun; Jean Emmanuel Bibault
Journal:  Front Oncol       Date:  2021-05-05       Impact factor: 6.244

9.  Reproducibility of lung nodule radiomic features: Multivariable and univariable investigations that account for interactions between CT acquisition and reconstruction parameters.

Authors:  Nastaran Emaminejad; Muhammad Wasil Wahi-Anwar; Grace Hyun J Kim; William Hsu; Matthew Brown; Michael McNitt-Gray
Journal:  Med Phys       Date:  2021-04-13       Impact factor: 4.506

10.  The Image Biomarker Standardization Initiative: Standardized Quantitative Radiomics for High-Throughput Image-based Phenotyping.

Authors:  Alex Zwanenburg; Martin Vallières; Mahmoud A Abdalah; Hugo J W L Aerts; Vincent Andrearczyk; Aditya Apte; Saeed Ashrafinia; Spyridon Bakas; Roelof J Beukinga; Ronald Boellaard; Marta Bogowicz; Luca Boldrini; Irène Buvat; Gary J R Cook; Christos Davatzikos; Adrien Depeursinge; Marie-Charlotte Desseroit; Nicola Dinapoli; Cuong Viet Dinh; Sebastian Echegaray; Issam El Naqa; Andriy Y Fedorov; Roberto Gatta; Robert J Gillies; Vicky Goh; Michael Götz; Matthias Guckenberger; Sung Min Ha; Mathieu Hatt; Fabian Isensee; Philippe Lambin; Stefan Leger; Ralph T H Leijenaar; Jacopo Lenkowicz; Fiona Lippert; Are Losnegård; Klaus H Maier-Hein; Olivier Morin; Henning Müller; Sandy Napel; Christophe Nioche; Fanny Orlhac; Sarthak Pati; Elisabeth A G Pfaehler; Arman Rahmim; Arvind U K Rao; Jonas Scherer; Muhammad Musib Siddique; Nanna M Sijtsema; Jairo Socarras Fernandez; Emiliano Spezi; Roel J H M Steenbakkers; Stephanie Tanadini-Lang; Daniela Thorwarth; Esther G C Troost; Taman Upadhaya; Vincenzo Valentini; Lisanne V van Dijk; Joost van Griethuysen; Floris H P van Velden; Philip Whybra; Christian Richter; Steffen Löck
Journal:  Radiology       Date:  2020-03-10       Impact factor: 29.146

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.