BACKGROUND: So far there is no "gold standard" test for the diagnosis of periprosthetic joint infection (PJI), compelling clinicians to rely on several serological and synovial fluid tests with no 100% accuracy. Synovial fluid viscosity is one of the parameters defining the rheology properties of synovial fluid. We hypothesized that patients with PJI may have a different level of synovial fluid viscosity and aimed to investigate the sensitivity and specificity of synovial fluid viscosity in detecting PJI. METHODS: This prospective study was initiated to enroll patients undergoing primary and revision arthroplasty. Our cohort consisted of 45 patients undergoing revision for PJI (n = 15), revision for aseptic failure (n = 15), and primary arthroplasty (n = 15). PJI was defined using the Musculoskeletal Infection Society criteria. In all patients, synovial fluid viscosity, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and plasma d-dimer levels were measured preoperatively. RESULTS: The synovial fluid viscosity level was significantly lower (P = .0011) in patients with PJI (7.93 mPa·s, range 3.0-15.0) than in patients with aseptic failure (13.11 mPa·s, range 6.3-20.4). Using Youden's index, 11.80 mPa·s was determined as the optimal threshold value for synovial fluid viscosity for the diagnosis of PJI. Synovial fluid viscosity outperformed CRP, ESR, and plasma d-dimer, with a sensitivity of 93.33% and a specificity of 66.67%. CONCLUSION: Synovial fluid viscosity seems to be on the same level of accuracy with CRP, ESR, and d-dimer regarding PJI detection and to be a promising marker for the diagnosis of PJI.
BACKGROUND: So far there is no "gold standard" test for the diagnosis of periprosthetic joint infection (PJI), compelling clinicians to rely on several serological and synovial fluid tests with no 100% accuracy. Synovial fluid viscosity is one of the parameters defining the rheology properties of synovial fluid. We hypothesized that patients with PJI may have a different level of synovial fluid viscosity and aimed to investigate the sensitivity and specificity of synovial fluid viscosity in detecting PJI. METHODS: This prospective study was initiated to enroll patients undergoing primary and revision arthroplasty. Our cohort consisted of 45 patients undergoing revision for PJI (n = 15), revision for aseptic failure (n = 15), and primary arthroplasty (n = 15). PJI was defined using the Musculoskeletal Infection Society criteria. In all patients, synovial fluid viscosity, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and plasma d-dimer levels were measured preoperatively. RESULTS: The synovial fluid viscosity level was significantly lower (P = .0011) in patients with PJI (7.93 mPa·s, range 3.0-15.0) than in patients with aseptic failure (13.11 mPa·s, range 6.3-20.4). Using Youden's index, 11.80 mPa·s was determined as the optimal threshold value for synovial fluid viscosity for the diagnosis of PJI. Synovial fluid viscosity outperformed CRP, ESR, and plasma d-dimer, with a sensitivity of 93.33% and a specificity of 66.67%. CONCLUSION: Synovial fluid viscosity seems to be on the same level of accuracy with CRP, ESR, and d-dimer regarding PJI detection and to be a promising marker for the diagnosis of PJI.
Authors: Thomas K Fehring; Keith A Fehring; Angela Hewlett; Carlos A Higuera; Jesse E Otero; Aaron J Tande Journal: J Bone Joint Surg Am Date: 2020-07-15 Impact factor: 6.558
Authors: M Fernandez-Sampedro; I Sanlés-González; C García-Ibarbia; N Fañanás-Rodríquez; M Fakkas-Fernández; M C Fariñas Journal: BMC Infect Dis Date: 2022-01-27 Impact factor: 3.090