| Literature DB >> 30799575 |
Ju Gang Nam1, Jeong Min Lee1,2,3, Sang Min Lee1, Hyo Jin Kang1, Eun Sun Lee4, Bo Yun Hur5, Jeong Hee Yoon1, EunJu Kim6, Mariya Doneva7.
Abstract
OBJECTIVE: To compare a high acceleration three-dimensional (3D) T1-weighted gradient-recalled-echo (GRE) sequence using the combined compressed sensing (CS)-sensitivity encoding (SENSE) method with a conventional 3D GRE sequence using SENSE, with respect to image quality and detectability of solid focal liver lesions (FLLs) in the hepatobiliary phase (HBP) of gadoxetic acid-enhanced liver MRI.Entities:
Keywords: CS-SENSE; Compressed sensing; Liver MRI; Parallel imaging; Sparse reconstruction; T1-weighted sequence
Mesh:
Substances:
Year: 2019 PMID: 30799575 PMCID: PMC6389821 DOI: 10.3348/kjr.2018.0310
Source DB: PubMed Journal: Korean J Radiol ISSN: 1229-6929 Impact factor: 3.500
Fig. 1Flowchart of inclusion and exclusion criteria of our main study population.
CS = compressed sensing, GRE = gradient-recalled-echo, HBP = hepatobiliary phase, SENSE = sensitivity coding, 3D = three-dimensional
MR Parameters of Two T1-Weighted mDixon-GRE Sequences of Hepatobiliary Phase Imaging of Gadoxetic Acid-Enhanced Liver MRI
| MR Parameters | Standard mDixon-GRE | CS-SENSE mDixon-GRE |
|---|---|---|
| TR/TE (msec) | 3.6/1.34 and 2.4 | 3.6/1.45 and 2.8 |
| Flip angle (°) | 10 | 10 |
| Bandwidth (Hz/pixel) | 1562.5 | 1562.5 |
| Field of view (mm2) | 380 × 380 | 380 × 380 |
| Slice thickness (ST/gap, mm) | 6/3 | 6/3 |
| Matrix size | 320 × 290 | 320 × 290 |
| Acquired voxel size (mm3) | 1.18 × 1.31 × 3.0 | 1.18 × 1.31 × 3.0 |
| Reconstructed voxel size (mm3) | 0.99 × 0.99 × 3.0 | 0.99 × 0.99 × 3.0 |
| Number of excitation | 1 | 1 |
| AF (phase × slice × extrareduction factor) | 2.8 (2 × 1.4) | 4.5 (2 × 1.4 × 1.6) |
| Acquisition time (sec) | 15 | 9 |
AF = acceleration factor, CS = compressed sensing, GRE = gradient-recalled-echo, SENSE = sensitivity encoding, TE = echo time, TR = repetition time
Scoring Scale for Various Parameters in Assessment of Image Quality for Each Hepatobiliary MR Scan
| Imaging Quality Parameter | Score | Scoring System |
|---|---|---|
| Spatial resolution | ||
| Liver edge and pancreas margin sharpness | 1–5 | Score 1, very poor; score 2, suboptimal; score 3, acceptable; score 4, above average; score 5, excellent |
| Hepatic vessel conspicuity | 1–5 | Score 1, non-diagnostic or not visible; score 2, minimal diagnostic information; score 3, visible anatomy with moderate blurring; score 4, good diagnostic quality with minimal blurring; score 5, excellent diagnostic quality with sharp borders |
| Bile duct conspicuity | 1–5 | Score 1, bile ducts not delineated; score 2, partly delineated with blurry margin; score 3, entire biliary system is shown with blurry margin; score 4, 2nd order branch was delineated with blurry margin or 1st order branch is delineated with clear margin; score 5, 1st and 2nd order branches are well delineated with clear margin |
| Noise and artifact | ||
| Image noise | 1–5 | Score 1, unacceptable; score 2, increased noise with above average level, affecting diagnosis; score 3, acceptable; score 4, good; score 5, excellent |
| Aliasing artifact | 1–3 | Score 1, multiple remained unzip artifacts; score 2, granular band at center; score 3, none |
| Motion artifact | 1–5 | Score 1, very severe, interfering organic anatomy interpretation; score 2, severe, interfering internal structure; score 3, moderate, interfering evaluating fine structure; score 4, mild artifacts; score 5, none |
| Fat suppression deficiency | 1–5 | Score 1, unreadable (signal inversion); score 2, of partial signal inversion with more than 25% of images; score 3, with 10–25% of image or slice; score 4, with less than 10% of image or slice; score 5, without signal inversion |
| Overall artifact level | 1–5 | Score 1, unreadable; score 2, poor; score 3, acceptable; score 4, good; score 5. excellent |
| Overall image quality | 1–5 | Score 1, unreadable; score 2, poor; score 3, acceptable; score 4, good; score 5, excellent |
Qualitative Analysis Results for Image Quality based on Consensus Reading of Two Independent Reviewers
| Imaging Quality Parameter | Consensus Reading | ICC | ||
|---|---|---|---|---|
| Standard mDixon-GRE | CS-SENSE mDixon-GRE | |||
| Image blurring | ||||
| Liver edge sharpness | 3.98 ± 0.75 (2–5) | 4.01 ± 0.74 (3–5) | 0.391 | 0.514 (0.396–0.632) |
| Pancreas margin | 3.56 ± 0.78 (1–5) | 3.53 ± 0.78 (1–5) | 0.596 | 0.548 (0.438–0.636) |
| Hepatic vessel conspicuity | 4.10 ± 0.96 (2–5) | 4.14 ± 0.96 (2–5) | 0.295 | 0.805 (0.757–0.852) |
| Bile duct conspicuity | 4.14 ± 1.06 (2–5) | 4.17 ± 1.03 (2–5) | 0.417 | 0.800 (0.746–0.845) |
| Noise and artifact | ||||
| Image noise | 3.01 ± 0.50 (2–4) | 2.53 ± 0.65 (2–4) | < 0.0001 | 0.538 (0.425–0.650) |
| Aliasing artifact | 2.75 ± 0.44 (2–3) | 2.42 ± 0.52 (1–3) | < 0.0001 | 0.728 (0.662–0.794) |
| Motion artifact | 3.69 ± 0.75 (2–5) | 3.85 ± 0.66 (2–5) | 0.005 | 0.739 (0.686–0.785) |
| Overall artifact level | 3.74 ± 0.62 (2–5) | 3.65 ± 0.70 (2–5) | 0.045 | 0.529 (0.415–0.644) |
| Fat suppression deficiency | 4.90 ± 0.33 (3–5) | 4.91 ± 0.32 (3–5) | -† | 0.726 (0.660–0.780) |
| Overall image quality | 3.72 ± 0.73 (2–5) | 3.70 ± 0.72 (2–5) | 0.663 | 0.713 (0.643–0.783) |
Values are mean ± standard deviation (range), ICC with its 95% confidence interval. *p values are from Wilcoxon signed-rank test, †p value was unable to be evaluated due to insufficient number of different values between two sequences. ICC = intraclass correlation coefficient
Fig. 259-year-old male patient who had undergone liver segmentectomy due to HCC underwent gadoxetic acid-enhanced MRI for surveillance of recurrence of HCC.
HBP standard mDixon-GRE image (A) shows severe motion artifacts (score 2) resulting in image blurring, and similar level of motion artifacts is also seen on other phases of standard mDixon-GRE images (C). Motion artifact level was significantly decreased to score of 4 on HBP CS-SENSE mDixon-GRE image (B) although image noise is more prominent than on standard mDixon-GRE image. HCC = hepatocellular carcinoma
Fig. 375-year-old female patient with multiple lesions of HCC.
Standard mDixon-GRE image obtained during HBP (A) shows severe motion artifacts (score 2). Contrarily, motion artifacts are significantly decreased to score of 4 on HBP CS-SENSE mDixon-GRE image (B). Note that CS-SENSE mDixon-GRE image demonstrates better lesion conspicuity as well as depiction of intrahepatic vessels and intrahepatic bile ducts. Similar level of motion artifacts was also demonstrated on portal venous phase image with standard mDixon-GRE images (C), representing limited breath-holding capacity of patient.
Fig. 465-year-old male patient with multiple HCCs.
Standard mDixon-GRE image (A) and CS-SENSE mDixon-GRE image (B) obtained during HBP showed similar level of motion artifact (both score 3). However, aliasing artifact was more prominent in CS-SENSE mDixon-GRE image (B, arrowheads).
Nodule- and Patient-Based Estimates in Detection of Solid Focal Liver Lesions
| MRI Technique | Analyzed Parameter | Reader 1 | Reader 2 | Reader 3 |
|---|---|---|---|---|
| Standard mDixon-GRE | Nodule-based | |||
| Detected nodule | 145 | 166 | 215 | |
| False negative | 56 | 44 | 20 | |
| False positive | 8 | 17 | 42 | |
| Detection rate (%) | 71.0 (137/193) | 77.2 (149/193) | 89.6 (173/193) | |
| FP rate* | 0.09 (8/91) | 0.19 (17/91) | 0.46 (42/91) | |
| Patient-based | ||||
| Specificity (%) | 84.6 (22/26) | 80.8 (21/26) | 88.5 (23/26) | |
| Sensitivity (%) | 85.7 (78/91) | 90.1 (82/91) | 94.5 (86/91) | |
| CS-SENSE mDixon-GRE | Nodule-based | |||
| Detected nodule | 141 | 167 | 208 | |
| False negative | 62 | 35 | 19 | |
| False positive | 10 | 9 | 34 | |
| Detection rate (%) | 67.9 (131/193) | 81.9 (158/193) | 90.2 (174/193) | |
| FP rate* | 0.11 (10/91) | 0.10 (9/91) | 0.37 (34/91) | |
| Patient-based | ||||
| Specificity (%) | 92.3 (24/26) | 92.3 (24/26) | 84.6 (22/26) | |
| Sensitivity (%) | 84.6 (77/91) | 90.1 (82/91) | 94.5 (86/91) |
*FP rates were calculated as total number of FP nodules divided by total number of positive liver mDixon-GRE images. FP = false positive
JAFROC FOM for Random Case, Fixed Reader Analysis in Detection of Solid Focal Liver Lesions
| MRI Technique | FOM | 95% CI of FOM | |
|---|---|---|---|
| Standard mDixon-GRE | 0.918 | 0.861, 0.975 | 0.142 |
| CS-SENSE mDixon-GRE | 0.953 | 0.922, 0.983 | |
| Difference† | 0.064 | -0.012, 0.081 | - |
*p values are from random case, fixed reader analysis from JAFROC analysis. †FOM using CS-SENSE mDixon-GRE images subtracted by FOM using standard mDixon-GRE images. CI = confidence interval, FOM = figure-of-merit, JAFROC = jackknife alternative free-response receiver operating characteristic