Literature DB >> 3079834

Treatment of subtrochanteric fractures with a sliding screw-plate device.

M E Ruff, L M Lubbers.   

Abstract

In a series of 45 subtrochanteric fractures treated with a sliding screw-plate device, union was achieved in 43 patients (95.3%). Most were Seinsheimer Type II C (9), Type IIIA (12), and Type V (18). Fractures were stabilized in a valgus position (average, 140 degrees), with primary medial displacement of the femoral shaft (25 patients). Radiographic analysis of the degree of postoperative impaction of the fragments correlated with the fracture pattern. Fractures with medial cortical comminution such as Type IIIA and Type V were the most unstable, with an average of 10.8 and 8.0 mm axial impaction, respectively, and were at the greatest risk of complication. The sliding screw-plate device is a reliable method of achieving union in subtrochanteric fractures.

Entities:  

Mesh:

Year:  1986        PMID: 3079834     DOI: 10.1097/00005373-198601000-00014

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  8 in total

1.  Treatment of subtrochanteric fractures. A comparison of the Gamma nail and the dynamic hip screw: short-term outcome in 58 patients.

Authors:  I Saarenpää; T Heikkinen; P Jalovaara
Journal:  Int Orthop       Date:  2006-04-22       Impact factor: 3.075

2.  Application of Materials as Medical Devices with Localized Drug Delivery Capabilities for Enhanced Wound Repair.

Authors:  Esther J Lee; Beom Kang Huh; Se Na Kim; Jae Yeon Lee; Chun Gwon Park; Antonios G Mikos; Young Bin Choy
Journal:  Prog Mater Sci       Date:  2017-06-13

3.  Treatment of subtrochanteric fractures of the femur: reduction on the traction table and fixation with dynamic condylar screw.

Authors:  G Blatter; M Janssen
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

4.  [Ender nail with interlocking mechanism or dynamic hip screw in pertrochanteric fractures? A prospective study extending its limits].

Authors:  B Muller; F Bonnaire; T Heckel; J H Jaeger; I Kempf; E H Kuner
Journal:  Unfallchirurgie       Date:  1994-02

5.  The dynamic condylar screw in the management of subtrochanteric fractures: does judicious use of biological fixation enhance overall results?

Authors:  Manzoor Ahmed Halwai; Shabir Ahmed Dhar; Mohammed Iqbal Wani; Mohammed Farooq Butt; Bashir Ahmed Mir; Murtaza Fazal Ali; Imtiyaz Hussain Dar
Journal:  Strategies Trauma Limb Reconstr       Date:  2007-12-01

6.  Treatment of subtrochanteric femoral fractures using Selfdynamisable internal fixator.

Authors:  Ivan D Micic; Milorad B Mitkovic; Il-Hyung Park; Desimir B Mladenovic; Predrag M Stojiljkovic; Zoran B Golubovic; In-Ho Jeon
Journal:  Clin Orthop Surg       Date:  2010-11-05

7.  Clinical Results of Complex Subtrochanteric Femoral Fractures with Long Cephalomedullary Hip Nail.

Authors:  Kwang-Kyoun Kim; Yougun Won; Danica H Smith; Gi-Soo Lee; Hee Young Lee
Journal:  Hip Pelvis       Date:  2017-06-02

8.  Lateral Cortical Notching in Revision of a Subtrochanteric Fracture Non-union with Breakage of a Cephalomedullary Nail.

Authors:  Christian Tinner; Nicolas Andreas Beckmann; Johannes Dominik Bastian
Journal:  J Orthop Case Rep       Date:  2020-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.